BlogApplication notes
Why is my coolant consumption so high?
- Type
- Application notes
- Published
- 20 November 2026
- Prepared by
- Technical team
- Product group
- Metalworking Fluids (MWF)
Topping up with fluid at the original strength is the usual response to a falling level, but if only water has left, that makes the sump richer and leaves the loss in place. What actually drains the sump can be evaporation, drag-out on chips and parts, mist and splash, leaks out and in, or dumping the sump too often, and one machine can have two or more of these.
A sump filled on Monday is low again by Thursday, and concentrate drums are being ordered noticeably more often. Same product, same machines, yet some machines drink far more than others, and top-ups grow more frequent in summer. Filling without knowing where the fluid goes never stops the loss.
High consumption costs more than purchases. Every top-up moves the concentration: too rich brings dermatitis, foam and sticky residue, too lean brings rust and bacteria (OSHA, 1999). Part of the missing fluid also reaches workers' lungs as mist, which the US National Institute for Occupational Safety and Health links to respiratory disease and sets an exposure limit for (NIOSH, 1998). This is why the UK Health and Safety Executive puts fluid quality at the centre of risk control (HSE, 2021). Consumption is a cost figure and also a signal of whether the fluid is under control.
Water-mix coolant is concentrate diluted in water to a few percent, and the diluted fluid is called working fluid. The concentrate carries a base oil, emulsifiers that keep oil and water mixed, corrosion inhibitors and biocides (Byers, 2017). The principle that separates the causes is simple. Evaporation takes water and leaves the concentrate behind, so sump concentration rises (HSE, 2021; OSHA, 1999). Losses by drag-out, splash or leaks take working fluid as it is, so concentration holds, or falls if the sump is topped up with water only (OSHA, 1999). Concentration is read on a refractometer, a handheld tool that needs only a few drops.
In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: for one week, log for each machine the water and concentrate added, refractometer concentration before and after each top-up, and sump temperature. That log first shows whether the loss is water or working fluid.
Hypothesis 1: evaporation
This stands out in summer, on high-speed or heavy-cut machines, on grinders that make a lot of heat, on sumps with a wide open surface and on equipment that sprays fluid widely. On a midsummer afternoon the wall of a grinder sump feels warm to the back of the hand, and the level set in the morning has dropped visibly by the end of the shift. The operator tops it up, as always, with working fluid mixed in advance.
Water goes first because of the job coolant does. One of its main tasks is to carry away the heat of cutting and grinding (Brinksmeier et al., 2015), so the fluid returns to the sump warm. When warm fluid meets air over a wide sump surface, a chip conveyor or a spray, water leaves as vapour. Base oil, emulsifiers and inhibitors mostly do not evaporate, so the same concentrate ends up in less water: the level drops while concentration climbs (OSHA, 1999).
Evaporation also feeds mist. Part of the fluid vaporises at the hot cutting zone and condenses again into very fine droplets as it cools, a reported route of mist formation (Leith & Thornburg, 1998; Sutherland et al., 2000), so the hotter the process, the more water loss and mist tend to rise together. What makes it worse is the top-up habit. Pouring working-strength fluid or concentrate into a sump that is already rich keeps concentration rising, which is why HSE advises topping up water-mix fluids that concentrate by evaporation at below the recommended strength (HSE, 2021).
The telling sign is a lower level with refractometer concentration above the recommended range (OSHA, 1999). Faster loss while running than over weekends, in summer than in winter, and on high-speed or heavy-cut machines adds weight to this hypothesis. Measure sump temperature weekly as well, and consider cooling if it runs well above the workroom (HSE, 2021). Skin complaints, sticky residue and more foam are symptoms of a rich mix (OSHA, 1999). Multiply refractometer readings by the supplier's refractometer factor to get true concentration, and use a refractometer with temperature compensation, since one without it can read far off as fluid temperature changes (Canter, 2011).
If concentration reads high, stop adding concentrate first and top up with water or fluid below the recommended strength, following the supplier's figure (HSE, 2021). If the sump runs hot, check whether it is too small for the workload and whether a chiller is needed (HSE, 2021). On machines that take a lot of water, look at make-up water quality too. Calcium and magnesium, the source of hardness, stay behind when water evaporates and build up, so check make-up water hardness and agree a suitable water quality with the supplier (HSE, 2021; Washington State Department of Ecology, 2025).
Hypothesis 2: drag-out
Look at this hypothesis on aluminium work with many fine chips, on parts with deep holes or internal passages, and on lines with high part counts. On a line turning out small aluminium parts nonstop, fluid sloshes at the bottom of the chip bin each time it is emptied at the end of the conveyor, and liquid drips from every hole when a box of parts is carried away. However closely the sump is inspected, no leak shows.
The thin film clinging to chips and parts is the loss itself. Fluid wets surfaces and clings to them, so the more surface area chips and parts have, and the more holes and pockets where fluid can pool, the more leaves the machine. Unlike evaporation, this loss takes water and concentrate together, so sump concentration stays about the same. The US Occupational Safety and Health Administration manual likewise treats loss at correct concentration as drag-out and advises topping up at the proper dilution (OSHA, 1999).
Ingredients cling to surfaces to different degrees, so active ingredients such as corrosion inhibitors can be depleted first (Canter, 2011; Washington State Department of Ecology, 2025). The concentration figure can then look right while rust protection weakens. Drag-out also leaves trouble outside the machine: fluid pooling in chip bins and parts boxes ends up as waste or on the floor, and fluid left on parts loads the next washing step.
Measuring it is straightforward. Choose one chip bin and one parts box, collect what drains to the bottom over a day, and set it against the daily top-up; a large share means drag-out is the main cause. In the log it shows as a falling level with concentration staying in range, or drifting lean after water-only top-ups (OSHA, 1999). It becomes clearer still if consumption tracks part count or chip volume rather than running hours.
The savings lie outside the machine. Give fluid the time and a path to drain back to the sump at the conveyor end or the chip bin, and where chip volume is large, consider a centrifugal wringer that spins the fluid out of the chips. If parts carry most of it, add a short air blow-off or spin-off at the end of the cycle, and unload parts so holes do not face up. Replace drag-out losses with working fluid at the recommended strength, not water alone, to keep concentration and active ingredients up (OSHA, 1999).
Hypothesis 3: mist and splash
This tends to happen on machines with high-pressure nozzles or through-spindle coolant, on high-speed spindles, and on equipment with open or gappy guards. Around a machining centre running high-pressure coolant, the floor always has a sheen, and fluid marks line the guard tops and door gaps. By afternoon a haze may show under the ceiling lights.
Research has confirmed three routes to mist: impaction, where a stream breaks on the workpiece or tool; fling, where rotating tools and parts throw fluid off; and vaporisation at high temperature followed by condensation (Leith & Thornburg, 1998; Sutherland et al., 2000). Process conditions change mist output a great deal. In turning experiments, machining conditions clearly changed the mass concentration of mist, and the authors argued that adjusting the process can cut mist without costly filters or enclosures (Gunter & Sutherland, 1999). The OSHA manual likewise says fine mist forms with high-pressure delivery and where streams break up (OSHA, 1999).
Scattered fluid leaves by two paths. Large drops splash past the guards onto the floor and clothing, while small ones hang in the air and leave through the mist collector or ventilation. Air drawn in at pump seals or suction ports mixes into the fluid and increases mist, and too rich a mix or entrained air makes foam that overflows the sump and guards, taking working fluid with it (OSHA, 1999).
Start by looking. Check whether the floor around the machine stays wet, whether fluid marks show on guards and door gaps, whether light halos under the lamps or nearby surfaces feel oily, and whether foam builds on the sump or chip conveyor. Mist collector filters that clog quickly, or fluid pooling at the collector outlet, are signs too, and a poorly maintained collector can actually raise the mist in the discharged air (OSHA, 1999). Airborne mist concentration needs professional sampling. The NIOSH recommended exposure limit, as a time-weighted average for up to 10 hours a day in a 40-hour week, is 0.4 mg/m³ thoracic particulate mass or 0.5 mg/m³ total particulate mass (NIOSH, 1998).
The fixes aim to break the fluid up less and to contain what does scatter. Aim nozzles squarely at the cutting zone and use only the pressure and flow the cut needs (OSHA, 1999). Splash guards may be enough on low-production machines, but high-production machines generally need full enclosure connected to exhaust (OSHA, 1999). Local exhaust ventilation performs only when properly designed, installed and examined at intervals (HSE, 2017), and mist control treats fluid care, product choice and exhaust as one system (ASTM International, 2023). If foam overflows, check concentration and air leaks at the pump suction first.
Hypothesis 4: leaks out and in
Suspect this on older machines, on equipment whose pump seals and hoses have not been changed for a long time, and on machines with hydraulics or slideways close to the coolant sump. A lathe that stood idle all weekend still shows a level below the line marked on Friday, and a band of dried residue lies on the floor beneath it. On the same machine an iridescent oil film floats on the sump, and hydraulic oil needs topping up more often than before.
Leaks run two ways. One is fluid leaking out: through pump seals, pipe joints, hoses, tank welds and gaps in the chip conveyor housing, working fluid slips away under the machine or into floor drains. Because whole working fluid leaves, concentration holds and the log looks much like drag-out. The other is oil leaking in. Hydraulic, slideway and gear oil reaching the sump is called tramp oil (HSE, 2021); it blurs refractometer readings and makes concentration hard to manage (Canter, 2011; Khan et al., 2021), and it destabilises the oil-in-water emulsion and feeds bacteria (Washington State Department of Ecology, 2025).
Oil that gets in turns into consumption this way: skimming the floating layer removes some working fluid with it, and once the oil mixes into the emulsion it is hard to remove at all, so the sump is dumped early. Performance suffers too: in one machining study, continuous hydraulic oil ingress made tool life and wear vary by up to 70% (Khan et al., 2021). HSE advises checking weekly that tramp oil stays below 2% (HSE, 2021).
A shutdown makes outward leaks easy to spot. Mark the level before and after, and if it drops while the machine stands, the leak has nothing to do with running. Look for wet marks or crusted residue under the machine, around the pump and at pipe joints. For oil leaking in, machine oil top-up records are the easiest evidence: an oil layer on the sump together with shorter hydraulic top-up intervals strongly suggests machine oil is getting into the coolant. A blurred refractometer line, or readings higher than they should be, is another sign (Canter, 2011).
Leaks are closed by maintenance. Put pump seals, hoses and joints on the maintenance plan with set replacement intervals, and stop any fluid reaching floor drains at once, since that is a wastewater problem. If machine oil is getting in, fix the leak and remove the floating oil with a skimmer or coalescer (HSE, 2021; Washington State Department of Ecology, 2025). Ask the supplier, too, whether the machine oils in use and the coolant are compatible (Washington State Department of Ecology, 2025).
Hypothesis 5: early dumping
This hypothesis comes to mind first when daily top-up looks normal but yearly concentrate purchases are high. It shows in shops that empty and refill the whole sump each time odour rises and the emulsion starts to split. Leaf through the change log and the same machine names come round every few months, each time with similar notes about smell and rust just before the change.
The reasons a fluid ends up being changed come down to a few: build-up of fine metal particles and hardness, growth of bacteria and fungi, tramp oil that breaks the emulsion, and loss of active ingredients through drag-out (Washington State Department of Ecology, 2025). Bacteria grow in a film called biofilm on chips, sump walls and dead spots in pipework (HSE, 2021; Washington State Department of Ecology, 2025). As they feed on emulsifiers and inhibitors and break the fluid down, odour, splitting and rust follow, and at that stage the shop chooses to dump. Research in the field sees extending in-use fluid life as the biggest lever for cutting both consumption and environmental burden (Skerlos et al., 2008).
The change log and dipslides provide the evidence. Set a year of change records against concentrate purchases to see what share full changes account for, and check whether odour, splitting or rust recur before each change. A dipslide is a test slide dipped in the fluid and incubated for a day or two, read as bacterial colonies per mL of fluid, or cfu/mL. At 10⁴ cfu/mL or more bacteria are growing, and at 10⁶ cfu/mL or more control has failed and the sump is normally drained and cleaned (HSE, 2021). A monthly sample in a clear glass jar, set beside fresh working fluid and compared for splitting and colour, lets a shop follow fluid condition without laboratory analysis (Washington State Department of Ecology, 2025).
Longer change intervals come from the basics more than from biocide. First correct concentration, pH, which is the degree of acidity or alkalinity, tramp oil, metal contamination, temperature and circulation, and use biocide at the supplier's dose only if bacteria keep growing (HSE, 2021). When changing the fluid, remove chips and sludge and clean the sump and lines before refilling, so leftover bacteria do not seed the new charge at once (Washington State Department of Ecology, 2025). Remove dead legs where flow stops, or flush them regularly (HSE, 2021).
Testing the hypotheses
There are five routes of loss, but one week of top-up records splits them into two broad groups: water leaving alone, and whole working fluid leaving. A log of water and concentrate added per machine, concentration before and after, and sump temperature is the basis for every judgement that follows.
If concentration keeps rising, evaporation, hypothesis 1, is the main cause: switch to water or a lean top-up and check sump temperature (HSE, 2021). If concentration holds or falls, whole working fluid is leaving, and the next steps find the route (OSHA, 1999).
The least effort goes into comparing the level across a shutdown. A drop while idle points to leaks out, hypothesis 4, and a look at any oil layer on the sump and the machine oil records at the same time covers leaks in (HSE, 2021). Next, collect and measure a day's drainage from a chip bin and a parts box; a large share of the top-up points to drag-out, hypothesis 2.
The gap that remains belongs to mist and splash, hypothesis 3. Look at the floor, guards and collector, check nozzle aim, pressure and flow, and arrange air sampling if mist is visible (NIOSH, 1998; OSHA, 1999). Finally, set a year of change records against concentrate purchases to see what share full changes account for, which settles hypothesis 5 (Washington State Department of Ecology, 2025).
Hypotheses often overlap on one machine. High-pressure machines lose to evaporation and mist together, and aluminium lines can lose heavily to both drag-out and evaporation. In such cases, take out the water-loss share first from the concentration trend, then split the remaining working-fluid loss into leaks, drag-out and splash, and the order of fixes follows. Keep the same log for a few weeks after the fixes; the job is done only when top-up volume and concentration settle together.
Limits and cautions
Concentration range, top-up strength and refractometer factor differ by product, so take figures from the product data sheet and the supplier. Neat oils, used without water, behave differently on evaporation and concentration, and the hypotheses above do not apply to them as written. Refractometer readings can run high with tramp oil and contamination (Canter, 2011), so when in doubt confirm with the supplier's titration, a chemical test that measures content by adding a reagent, or with laboratory analysis.
If mist is visible, or workers report coughing, breathlessness or skin symptoms, treat it as a health issue rather than a consumption issue, and leave air sampling and exhaust checks to an occupational hygienist (HSE, 2017; NIOSH, 1998). When cleaning sumps, removing chips or handling concentrate and biocide, check the product's safety data sheet, the SDS, wear chemical-resistant gloves and eye protection, and remove chips only with the machine off (HSE, 2021). Handle spent fluid and fluid that reached the floor under local regulations, and if any may have entered a drain, tell the environmental lead at once.
Sources
- ASTM International. (2023). ASTM E2889-23, Standard practice for control of respiratory hazards in the metal removal fluid environment. https://store.astm.org/e2889-23.html
- Brinksmeier, E., Meyer, D., Huesmann-Cordes, A. G., & Herrmann, C. (2015). Metalworking fluids: Mechanisms and performance. CIRP Annals, 64(2), 605–628. https://doi.org/10.1016/j.cirp.2015.05.003
- Byers, J. P. (Ed.). (2017). Metalworking fluids (3rd ed.). CRC Press.
- Canter, N. (2011, March). Monitoring metalworking fluids. Tribology & Lubrication Technology. https://www.stle.org/files/TLTArchives/2011/03_March/Cover_Story.aspx
- Gunter, K. L., & Sutherland, J. W. (1999). An experimental investigation into the effect of process conditions on the mass concentration of cutting fluid mist in turning. Journal of Cleaner Production, 7(5), 341–350. https://doi.org/10.1016/S0959-6526(99)00150-X
- Health and Safety Executive [HSE]. (2017). HSG258, Controlling airborne contaminants at work: A guide to local exhaust ventilation (3rd ed.). https://www.hse.gov.uk/pubns/books/hsg258.htm
- Health and Safety Executive [HSE]. (2021). MW5, Managing fluid quality: COSHH essentials for machining with metalworking fluids. https://www.hse.gov.uk/pubns/guidance/mw5.pdf
- Khan, T., Broderick, M., & Taylor, C. M. (2021). Investigating the industrial impact of hydraulic oil contamination on tool wear during machining and the development of a novel quantification methodology. International Journal of Advanced Manufacturing Technology, 112(1–2), 589–600. https://doi.org/10.1007/s00170-020-06370-y
- Leith, D., & Thornburg, J. (1998). Factors that affect generation of coolant mists. NIOSH-funded research report, NTIS PB2001-101409. https://ntrl.ntis.gov/NTRL/dashboard/searchResults/titleDetail/PB2001101409.xhtml
- National Institute for Occupational Safety and Health [NIOSH]. (1998). Criteria for a recommended standard: Occupational exposure to metalworking fluids (DHHS [NIOSH] Publication No. 98-102). https://www.cdc.gov/niosh/docs/98-102/
- Occupational Safety and Health Administration [OSHA]. (1999). Metalworking fluids: Safety and health best practices manual. U.S. Department of Labor. https://www.osha.gov/metalworking-fluids/manual
- Skerlos, S. J., Hayes, K. F., Clarens, A. F., & Zhao, F. (2008). Current advances in sustainable metalworking fluids research. International Journal of Sustainable Manufacturing, 1(1/2), 180–202. https://inderscience.com/offers.php?id=19233
- Sutherland, J. W., Kulur, V. N., & King, N. C. (2000). An experimental investigation of air quality in wet and dry turning. CIRP Annals, 49(1), 61–64. https://doi.org/10.1016/S0007-8506(07)62896-0
- Washington State Department of Ecology. (2025, October). Machine shop checklist #2B: Water-based metalworking fluid management (Publication 25-04-052). https://apps.ecology.wa.gov/publications/UIPages/documents/2504052.pdf