Adding more defoamer is the usual response to rising foam, but it hides the cause and, overdosed, creates new trouble. What actually builds the foam can be air entrainment, high concentration, very soft water, spent defoamer or cleaner contamination, and two or more can combine, as when the fluid holds the air the equipment drives in.

Foam rises over the sump and spills through the gaps in the lid, and white froth spreads around the chip conveyor and across the floor. An operator pours in a cup of defoamer, the foam settles for a while, and the next day it is back. The machine next door runs quietly on the same fluid, and nobody can tell why this one foams, or whether the fluid or the machine is to blame.

Foam is more than an eyesore. Persistent foam blocks heat transfer and weakens cooling, causes cavitation at the pump impeller, fouls filters, overflows sumps, interferes with lubrication and adds to mist and bioaerosol formation (ASTM International, 2021). In high-pressure supply, aerated fluid compresses and delivery suffers (Canter, 2015). Coolant mist is an exposure route linked to respiratory disease, so foam control also touches worker health (NIOSH, 1998; OSHA, n.d.).

Foam is a mass of air bubbles held in a liquid. Bubbles in clean water burst at once, but when a surfactant is dissolved, a thin liquid film forms around each bubble and does not tear easily. Where the film stretches and thins, the surfactant at the surface is spread thinner, the surface tension rises and the surrounding liquid is pulled back in, thickening the film again. This self-healing property, called Gibbs–Marangoni elasticity, is the main reason foam lasts (Pugh, 1996, 2016). Water-mix coolants carry a lot of emulsifier, that is, surfactant, to keep oil and water mixed, so they foam easily by nature, and semi-synthetics and soluble oils, rich in emulsifier, see a lot of foam trouble. Makers therefore add defoamer to the concentrate to strike a balance, but that balance keeps shifting in use with the water, the concentration, the equipment and contamination (Canter, 2015; McGuire, 2024).

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The opening move never changes: measure concentration with a refractometer against the recommended range, and on the same day shake a bottle of sump fluid and time how long the foam takes to collapse. If it dies quickly in the bottle but builds only in the machine, look first at the equipment hypotheses; if it lingers in the bottle too, look first at the fluid.

Hypothesis 1: air entrainment

It tends to start after high-pressure coolant is added, nozzles are changed or supply pressure is raised. Sumps where the return falls onto the surface from a height, where the return sits close to the pump inlet, or where a low level lets a vortex form around the inlet belong here too. One example is a machining centre fitted with high-pressure coolant to raise output. From the week after the fit, foam starts to build on the sump, and the fluid falling from the return trough hits the surface louder than before.

Foam needs air to get in. When fluid is sprayed at high speed or falls from a height into the sump, the jet punches through the surface, drags in surrounding air and breaks it into many small bubbles (Biń, 1993). Smaller bubbles rise more slowly, so in a small sump or with fast circulation they lack the time to reach the surface and burst, and they are drawn back into the pump (Canter, 2015; McGuire, 2024). When a blocked or worn inlet lets pressure inside the pump drop, bubbles form and burst there, which is cavitation, and that too makes bubbles on its own (Canter, 2015).

Industry experts single out supply pressure as a major factor. Typical fluids cope well up to roughly 500 to 600 psi, about 35 to 40 bar; above that a specially made low-foam fluid may be needed, and high-pressure machines running above 800 psi, about 55 bar, add to foam on their own (McGuire, 2024). This is why foam rises as pressure and flow are pushed up for output (Canter, 2015; McGuire, 2024).

The bottle shake is the first check that separates equipment from fluid. If a shaken bottle of sump fluid clears quickly but foam still builds in the machine's sump, the equipment, not the fluid, is putting the air in. Then see whether the return falls onto the surface, whether it sits close to the inlet, and whether a low level lets a vortex form near the inlet. A gravel-like noise from the pump or a fluttering pressure gauge points to cavitation.

The answer is to close off the ways air gets in. Extend the return pipe below the surface or run it down a sloped plate to cut the fall, and keep the return away from the pump inlet (Biń, 1993). Hold the fluid at its set level, and use a baffle to separate the return side from the suction side so bubbles have room to rise (Canter, 2015; McGuire, 2024). Inspect the suction strainer for blockage, the line for air leaks and the impeller for wear as well (Canter, 2015). If the process needs supply pressure beyond what typical fluids handle, review a low-foam product with the supplier (McGuire, 2024).

Hypothesis 2: high concentration

This hypothesis belongs where water evaporates fast: in summer, on machines with warm fluid, and on small, fast-circulating sumps. The same goes for sites that always top up with mix at working strength or pour in concentrate by eye. A lathe with a small sump, topped up all summer only with mix at working strength, is such a case. Along with the extra foam comes the remark that the fluid feels stickier on the hands than before.

The more surfactant there is, the faster and more densely a bubble surface is covered, and the more molecules are on hand to refill it as the film stretches, so foam forms readily and lasts (Pugh, 1996, 2016). Water-mix fluids grow stronger as water evaporates in use (HSE, 2021), so topping up with mix at working strength instead of a weaker one drives concentration above the recommended range. Concentration above the recommendation is named as a standard field cause of foam (Canter, 2015; McGuire, 2024).

A strong mix causes trouble beyond foam. High concentration raises skin and airway irritation, while low concentration raises the risk of microbial growth and corrosion, so public guidance asks for concentration to stay within the supplier's recommended range (HSE, 2021; OSHA, n.d.).

A refractometer reading settles most of it. The scale reading must be multiplied by the refractometer factor on the product sheet to give the true concentration, and the prism should be cleaned and zeroed before reading. Guidance from the UK Health and Safety Executive, HSE, advises checking concentration and pH every week (HSE, 2021). If foam comes with fluid that feels sticky or with more complaints of skin irritation, lean towards high concentration.

Above range, top up with water or a mix weaker than working strength to bring it back. On machines with heavy evaporation, set the top-up mix weaker from the start, and record readings and top-up volumes together (HSE, 2021). Instead of pouring concentrate by eye, make the mix with a proportioning mixer, and concentration stays steady.

Hypothesis 3: very soft water

This hypothesis surfaces after water treatment or a softener is installed, or after dilution water is switched from well water to deionised or reverse osmosis water. Take a plant that installs reverse osmosis to improve its water and starts mixing coolant with it. The concentrate and the concentration are unchanged, yet the foam on the sump has grown noticeably.

Water hardness is the amount of calcium and magnesium dissolved in the water. Anionic emulsifiers in water-mix coolants, such as fatty acid soaps, meet these ions and form calcium soaps that barely dissolve, and these fine calcium soap particles act like antifoam particles that pierce bubble films, pushing towards less foam (Canter, 2015; McGuire, 2024). Softened, deionised and reverse osmosis water have almost none of these ions, so all of the emulsifier goes into holding films, and foam increases. Deionised water is reported to give the most foam as a rule (McGuire, 2024), and the standard guide likewise states that fluids diluted with hard water foam less than those diluted with soft, deionised or reverse osmosis water (ASTM International, 2021).

That does not make harder always better. Very hard water ties up too much emulsifier through the same reaction, weakening the emulsion and forming scum. Dilution water is kept neither too soft nor too hard, and since the right range differs by product, the maker's recommendation applies (Canter, 2015; McGuire, 2024).

Mixing with a different water shows the difference at once. Measure the total hardness of the dilution water with test strips or a titration kit, then make up the same concentrate at the same strength in the current water and in ordinary tap water, and shake the two bottles side by side (ASTM International, 2021). Foam that eases when hard water is mixed in and returns after deionised top-ups is another sign.

Bring dilution-water hardness into the maker's range. If only deionised water is used, set a blend ratio with tap water, or review a hardness adjuster with the maker (Canter, 2015; McGuire, 2024). Before switching water supply, compare foam from a mix made in the new water with a bottle shake (ASTM International, 2021), and where deionised water is a must, choose a product made to foam little in soft water (McGuire, 2024).

Hypothesis 4: spent defoamer

Defoamer is prone to run down in systems where a fine filter was added or the filter grade tightened, in high-pressure circuits where the pump churns the fluid hard, and in sumps run for a long time without a recharge. Picture a sump whose fresh charge stays quiet for a while, then foams a little more each week, settles for a few days after a dose of defoamer and then rises again. The doses come closer and closer together.

How a defoamer works also explains why it runs down. A defoamer is an insoluble oil droplet, often silicone oil or an oil blended with hydrophobic particles. When a droplet reaches the surface of a foam film and forms a bridge between its two faces, the film thins at that bridge and tears (Denkov, 2004; Denkov et al., 1999). So a defoamer that dissolves fully does nothing, and one that dissolves too little separates and floats off; it must stay as a fine dispersion (Garrett, 2013; McGuire, 2024).

In use these droplets dwindle by several routes. Being water-repelling, the defoamer is easily caught by fine filters, and it sticks more readily to water-repelling polypropylene filters than to nylon ones (McGuire, 2024). Particle-type defoamers are broken up too finely by pump shear, the hard tearing action inside the pump, and lose their effect, and the spent particles settle or are filtered out (Canter, 2015). Experiments have also shown exhaustion, in which the particles in each droplet separate from the oil as it keeps breaking foam, so the defoaming power fades (Denkov, 2004).

Testing this hypothesis needs a reference sample. Shake a fresh mix of the same concentrate and the sump fluid side by side at the same strength; if only the sump fluid holds foam, suspect defoamer depletion. The standard guide also notes that no single test predicts real foaming and advises comparing against a reference sample (ASTM International, 2021). Check the records, too, for whether the rise in foam lines up with a fine filter being added or the grade being changed (McGuire, 2024).

Dose defoamer sparingly and in steps. Concentrated tankside defoamers are easy to overdose, and too much will not disperse in the sump but builds into a thick film that is hard to remove. When changing filter grade or material, check with the supplier whether the defoamer will be stripped out (McGuire, 2024). Log the interval between additions, and if doses are needed more and more often, look again for another hypothesis on top, such as concentration or cleaner contamination (Canter, 2015).

Hypothesis 5: cleaner contamination

Look at this hypothesis when foam jumps right after a particular job, such as floor cleaning, tank cleaning or a fluid change. Typical are plants that wash the floor around machines with cleaner, and layouts where wash water can run into the sump along a chip conveyor or drain. Say the floor around a machine gets a thorough wash with cleaner over the weekend; when the pump starts on Monday morning, foam surges over the sump all at once.

Many floor and machine cleaners carry large amounts of surfactant made to foam on purpose. If tanks or lines are poorly rinsed after cleaning, or floor-wash water runs into the sump, these components mix into the coolant, and the industry names floor cleaners as a major outside source of foam (Canter, 2015; McGuire, 2024). The added surfactant makes bubble films tougher, and a strongly alkaline cleaner can break down a silicone defoamer and disable it (Canter, 2015). Foam is fed from both sides at once: more of what builds it, less of what breaks it.

Start by asking which cleaner was used, where and when, and where its water drains. A refractometer reading that rises for no clear reason, or a pH that moves unusually, can signal that another liquid has got in. Catching the rinse water after cleaning in a bottle and shaking it shows easily whether cleaner remains.

If cleaner is behind it, cut off its path and rinse thoroughly. After tank cleaning, shake a bottle of the rinse water to confirm it no longer foams before filling with fresh fluid (McGuire, 2024). When washing floors around machines, keep the water out of chip conveyors and sumps, and use a low-foam machine cleaner that the supplier has confirmed is safe to mix with the coolant (Canter, 2015). If so much cleaner got in that concentration control and defoamer cannot hold it, drain, clean and refill the sump.

Testing the hypotheses

The foam hypotheses split broadly into the equipment, which puts air in, and the fluid, which holds the foam. Separate these two first, and the rest narrows quickly.

The starting point is writing down when it began. List what changed around the time foam rose: equipment, nozzles, pressure, filters, dilution water, cleaning work and fluid changes. Then multiply the refractometer reading by its factor, compare it with the range, and if it is high, dilute first and look again. That screens hypothesis 2 (HSE, 2021).

Next, split fluid from equipment with a bottle shake. Half-fill a bottle with sump fluid, shake it a set number of times and time the collapse. Quick collapse points to the equipment, hypothesis 1, so check return fall, fluid level, inlet vortices, pump cavitation and changes in supply pressure (Biń, 1993; McGuire, 2024). Lingering foam moves the search to the fluid hypotheses (ASTM International, 2021; Canter, 2015).

On the fluid side, a control test separates hypotheses 3 to 5. Make a fresh mix of the same concentrate at the same strength and shake it alongside the sump fluid. If the fresh mix foams too, the water is the suspect, hypothesis 3, and where deionised or softened water is used, compare once more with a mix made in tap water. If the fresh mix is fine and only the sump fluid holds foam, it is hypothesis 4 or 5: a sudden rise leans towards cleaner, a slow rise towards spent defoamer (ASTM International, 2021; Canter, 2015; McGuire, 2024). The last check is to repeat the same bottle shake after the fix and see whether the collapse time is now close to that of fresh fluid.

Hypotheses can also stack up, as on a high-pressure machine running a strong mix in soft water, where the strong fluid holds the air the equipment drives in. Then fix the easy, high-impact items first, concentration and fluid level, then dilution water and return piping, and only after that defoamer or a change of product. Reaching for more defoamer first hides the cause and can add the problems of overdosing (McGuire, 2024).

Limits and cautions

Control figures such as concentration, hardness and pressure limits differ by product, so read the values cited in the sources as industry experience, and base actual decisions on the product's data sheet and the maker's recommendations. The bottle shake is a quick comparison, and the standard guide itself states that no single test predicts real foaming (ASTM International, 2021).

Foamy fluid can make more mist, so keep local exhaust and mist control running while the cause is found (NIOSH, 1998; OSHA, n.d.). Before handling defoamers, cleaners or hardness adjusters, read each product's safety data sheet, the SDS, and wear protective gloves and safety glasses. Keep records of concentration, pH and fluid condition checks (HSE, 2021).

Hand the problem to the supplier or a specialist when foam persists after every step above, when designing or changing high-pressure supply, when foam comes with other faults such as odour, discolouration or separation, and when workers report skin or breathing symptoms (NIOSH, 1998; OSHA, n.d.).

Sources

  1. ASTM International. (2021). ASTM E3265-21, Standard guide for evaluating water-miscible metalworking fluid foaming tendency. https://store.astm.org/e3265-21.html
  2. Biń, A. K. (1993). Gas entrainment by plunging liquid jets. Chemical Engineering Science, 48(21), 3585–3630. https://doi.org/10.1016/0009-2509(93)81019-R
  3. Canter, N. (2015, December). Foam: Dealing with a persistent problem. Tribology & Lubrication Technology. https://www.stle.org/files/TLTArchives/2015/12_December/Feature.aspx
  4. Denkov, N. D. (2004). Mechanisms of foam destruction by oil-based antifoams. Langmuir, 20(22), 9463–9505. https://doi.org/10.1021/la049676o
  5. Denkov, N. D., Cooper, P., & Martin, J.-Y. (1999). Mechanisms of action of mixed solid–liquid antifoams. 1. Dynamics of foam film rupture. Langmuir, 15(24), 8514–8529. https://doi.org/10.1021/la9902136
  6. Garrett, P. R. (2013). The science of defoaming: Theory, experiment and applications. Surfactant Science Series. CRC Press.
  7. Health and Safety Executive [HSE]. (2021). MW5, Managing fluid quality: COSHH essentials for machining with metalworking fluids. https://www.hse.gov.uk/pubns/guidance/mw5.pdf
  8. McGuire, N. (2024, March). Metalworking fluid defoamers cut through the froth. Tribology & Lubrication Technology. https://www.stle.org/files/TLTArchives/2024/03_March/Cover_Story.aspx
  9. National Institute for Occupational Safety and Health [NIOSH]. (1998). Criteria for a recommended standard: Occupational exposure to metalworking fluids (DHHS [NIOSH] Publication No. 98-102). https://www.cdc.gov/niosh/docs/98-102/
  10. Occupational Safety and Health Administration [OSHA]. (n.d.). Metalworking fluids: Safety and health best practices manual. U.S. Department of Labor. https://www.osha.gov/metalworking-fluids/manual
  11. Pugh, R. J. (1996). Foaming, foam films, antifoaming and defoaming. Advances in Colloid and Interface Science, 64, 67–142. https://doi.org/10.1016/0001-8686(95)00280-4
  12. Pugh, R. J. (2016). Bubble and foam chemistry. Cambridge University Press.

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.