BlogApplication notes
Why does grease stiffen in winter and make machines hard to turn?
- Type
- Application notes
- Published
- 18 August 2025
- Prepared by
- Jonghwan Moon
- Product group
- Greases
Running a warm-up and waiting for milder weather is the usual response when machines turn heavily on winter mornings, but that only gets the day's start through, and the reason the grease stiffens at that temperature remains. What actually lies behind it can be base oil too thick for the temperature, too stiff a consistency grade, pumping that fails in the cold, frozen water or a grease unsuited to the season, and sometimes two or more at once.
Background
After a night below freezing, a conveyor or pump started in the morning draws more current than usual and struggles up to speed, or trips its overload. The shaft feels stiff when turned by hand, and the centralised lubrication system builds more pressure than usual yet fails to get grease to the points at the far end of the line. By the afternoon, or by spring, the same machine turns freely as if nothing had happened.
The heaviness does not stop at a slow start. While pushing through stiff grease, motors and gearboxes work harder, and a tripped breaker stops the line. The larger loss is out of sight. When stiffened grease cannot reach its lubrication points, bearings run short of lubricant, and grease that has lost pumpability can cause early failures in centralised lubrication systems (Peskoe-Yang, 2020).
Grease is a semi-solid in which a network of fine thickener fibres holds the oil, called base oil. Its structure and flow are set by the types of base oil and thickener and by the amount of thickener (Hodapp et al., 2022). As the temperature falls, the base oil thickens and the network stiffens, so the yield stress, the force needed to make grease start moving, and the starting torque, the torque needed to turn a bearing from rest, both rise. In a study of six bearing greases, both values changed exponentially with temperature, the slope changed below a certain low temperature, and this break point was related to the pour point of the base oil (Cyriac et al., 2016b).
In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: note the lowest operating temperature, the consistency grade and the base oil viscosity from the technical data sheet, the TDS, of the grease in use, and compare them with the actual temperature at that spot on the mornings the machine ran heavy.
Hypothesis 1: thick base oil
Base oil viscosity is chosen for load and speed when a grease is selected. Slow, heavily loaded bearings and gears sometimes get grease with a high base oil viscosity, and when that grease stays in unheated buildings or outdoor plant all year round, this hypothesis comes up in winter. Watch for it more closely with mineral oil-based greases. Picture a belt conveyor in an outdoor stockyard in midwinter. A pulley bearing that gave no trouble all summer is unusually heavy only at the first start of the morning, and after running a while it turns as lightly as ever.
It is heavy only in the morning because base oil is sensitive to temperature. Oil viscosity rises as temperature falls, and the lower an oil's viscosity index, rated from its viscosities at 40 °C and 100 °C, the more its viscosity changes over the same temperature span (ASTM International, 2024). Once the thickener structure was mostly broken down by shearing, a higher base oil viscosity meant higher resistance to flow (Delgado et al., 2006), so a thick base oil weighs not only on the moment of starting but on running torque as well. At low temperature, changes of state add to this. In synthetic oil greases, grease viscosity began to rise sharply near the pour point of the base oil, while in mineral oil greases the thickener brought oil crystallisation forward, so the pour point of the base oil alone could not properly set the lowest application temperature (Conrad et al., 2022).
The easiest clue is change over time. Log motor current just after starting and after a good while of running, see whether the gap follows the morning temperature, and confirm base oil viscosity and type in the TDS. If the same grease is fine in indoor plant and heavy only outdoors, this hypothesis gains weight. For a closer comparison, a laboratory can run the standard test that fills a slow-speed ball bearing with grease and measures starting and running torque at low temperature (ASTM International, 2020).
If thick base oil looks like the cause, review with the supplier a switch to a grease with the same thickener and grade but a lower base oil viscosity, or a synthetic base oil with a higher viscosity index. Base oil performance at low temperature can give a good indication of the finished grease's low-temperature properties (Peskoe-Yang, 2020). Base oil viscosity also sets the film that carries load at operating temperature, though, so decide how far to lower it with the bearing maker's recommended viscosity and the summer maximum temperature side by side.
Hypothesis 2: too stiff a grade
Grease stiffness is chosen by consistency grade. Look at this hypothesis when an NLGI 2 grease picked for summer or indoor conditions stays in use through winter, or when a stiff, high-thickener grease is fed through long lubrication lines or small fill ports. On a winter morning the fitter finds the grease gun lever far harder to push than in autumn, and the grease leaving the nipple breaks off in lumps instead of spreading smoothly. Same machine, same grease; only the temperature has changed.
The consistency grade is rated by working the grease a set number of strokes and measuring how deep a cone sinks into it at 25 °C. In tenths of a millimetre, NLGI 1 is 310 to 340 and NLGI 2 is 265 to 295, and the higher the NLGI number, the stiffer the grease and the less the cone sinks (ASTM International, 2021a). The same standard notes that no correlation has been established between this value and field service, so a grade rated at room temperature does not tell how stiff the grease is on a winter morning. Much of the stiffness comes from the amount of thickener. The network grew stronger as thickener concentration rose (Delgado et al., 2006), and the thickener also seeds crystallisation of the base oil, so in greases on a trimellitate ester base oil, more oil crystallised on cooling as the thickener content increased (Conrad et al., 2022).
Start with the NLGI grade and thickener type on the TDS and the drum label. Then take two dabs from the same drum, leave one at room temperature and one overnight beside the outdoor machine, and lift each with a spatula in the morning to feel how much stiffer the same grease becomes with the cold. Check also whether the amount delivered per stroke of the grease gun drops noticeably in winter, and whether the grade matches what the bearing maker or lubrication system maker recommends.
If the grade is at fault, review with the supplier a step down to NLGI 1 in the same base oil and thickener family. Less thickener also means a weaker network, so after the change watch for a while whether grease slumps or leaks from high-vibration positions or vertical-shaft bearings. If morning starts are still heavy on the softer grease, look at base oil viscosity as well.
Hypothesis 3: poor cold pumping
With a centralised lubrication system, which pumps grease out to many lubrication points, this hypothesis comes to mind first. The longer and narrower the lines, the more they run outdoors or along cold, windy walls, and the farther the distributors are from the pump, the more readily trouble shows in winter. In a plant with widely scattered equipment, points near the pump stay fine while bearings at the far end of the line start to get noisy once winter sets in. Meanwhile the pump pressure gauge needle sits higher than usual.
Grease does not flow like water; it moves only once the force at the pipe wall exceeds its yield stress. A study that modelled the lubrication system of wind turbines found grease yield stress rising clearly as temperature fell, especially below −35 °C (Yan et al., 2020). In the same study, temperature had the largest effect on pressure loss in the lines, followed by the diameter of the high-pressure line and then the flow rate. When pressure loss exceeds what the pump can deliver, grease stalls partway along the line and the far points starve first. A lower base oil viscosity improves pumpability in the cold, and the type and amount of thickener set the cohesion of the network and so affect flow (Peskoe-Yang, 2020).
In a lubrication system the numbers are right there. Compare pump delivery pressure and cycle time with the autumn records, and check the distributor indicators, or whether grease actually emerges at each point, working outwards from the pump. How easily a grease flows at low temperature can be compared by a test that measures the pressure needed to push it through a small nozzle, the flow pressure, at a set low temperature (DIN, 2016). Other tests are used for lubrication systems, but they are not standardised, which limits how widely they apply (Peskoe-Yang, 2020).
When cold pumpability is the worry, the usual recommendation is a grease of a lower consistency grade (Peskoe-Yang, 2020). Before changing grade, confirm the grades and maximum pressure the system maker allows, insulate or trace-heat lines that run outdoors, and where possible enlarge the line diameter on the sections far from the pump. In winter, adjusting the lubrication interval so grease does not sit still in the lines for long is also worth considering.
Hypothesis 4: frozen water
Where water comes and goes, keep this hypothesis on the list: equipment washed down with water, outdoor bearings exposed to rain and snow, housings where condensation forms with the swing between day and night temperatures, and places like the door of a cold store where warm and cold air meet. Think of a roller conveyor running past a cold store entrance. Each time the door opens, outside air comes in and moisture beads on the cold housings, and this line judders at its first start only on mornings after the temperature has dropped below zero.
Water changes grease even before it freezes. Water strongly affects a grease's viscosity at near-zero flow, its yield stress and its elasticity; calcium sulfonate greases stiffened after taking up water, while lithium, lithium complex and polyurea greases softened (Cyriac et al., 2016a). A study of aviation greases explains that below freezing, water in a lubricant freezes and interferes with friction parts, and ice crystals that have not fully thawed can enter the contact and act as an abrasive (Al-Quraan et al., 2025). Yet in the same study's sliding tests, a lithium grease that sheds water well lost no wear resistance with up to 20% water, so the effect of water differs from grease to grease.
Look for traces of water first. Check the housing floor and around the seals for droplets or rust, and see whether the grease removed shows any water. Match the records to see whether symptoms cluster on the day after a frost or after a wash-down, and if water is suspected, send a grease sample to a laboratory for water content. Confirm the thickener type of the grease in use as well, since winter symptoms can differ depending on whether the grease stiffens or softens when it takes up water.
If water is the cause, close off its way in first. Inspect seals and covers, keep wash-down jets off the bearings, and purge wet grease thoroughly with fresh grease. When reselecting the grease, note that the grease classification standard gives a symbol for lubrication and rust protection under water contamination, so weigh that symbol together with the water resistance results on the TDS and decide with the supplier (ISO, 2003).
Hypothesis 5: off-season grease
Where a plant runs all its equipment on one or two greases all year, or keeps using through winter a grease chosen for the hot season or for hot equipment, the grease choice itself may be out of step with the season. The same goes for purchases that checked only the maximum operating temperature and never the minimum. If a high-temperature grease chosen for the fan bearings beside a drying oven also goes, from the same drum, onto an outdoor conveyor, the fan by the oven is fine all winter while the outdoor conveyor grows heavy whenever a cold wind blows.
Every grease has a temperature range it can be used in. The international grease classification writes the lowest and the highest operating temperature into the grease's designation as one letter each, set for the most severe conditions in which that grease can be used (ISO, 2003). A grease aimed at the hot end may have a high limit at the cold end, so choosing by one end alone invites trouble at the other. Even the lowest operating temperature figure needs a look at how it was set. The low-temperature limit is commonly measured by starting torque, yet for six greases the temperature set this way was far below the point where the slope of their yield stress changed, and the starting torque criterion was measured on a particular bearing under particular conditions (Cyriac et al., 2016b). The low-temperature torque test for automotive wheel bearings is likewise for specifications, and its standard states that the user must establish how it relates to other service (ASTM International, 2021b).
Make a list of which grease goes into which equipment, find in each TDS the lowest operating temperature and the test that set it, and write it next to the winter minimum temperature at that equipment's location. If, among machines on the same grease, only those outdoors or in cold spots run heavy, this hypothesis is strong. Ask the equipment maker as well whether the grease filled at delivery was chosen for a warmer climate.
The remedy is to re-sort the grease list by temperature conditions. Stop covering hot and cold equipment with one grease; for outdoor plant, choose a grease whose lowest operating temperature is below the local winter minimum, or plan a switch between winter and summer greases. When changing, confirm with the supplier that the old and new greases can mix, and pump in new grease until the old has all been pushed out.
Finding the cause
Rather than investigating all five hypotheses at once, rule out first what can be checked at a desk. The grease list, the TDS and the temperature records can be read on the spot, and the lubrication system's pressure and cycle records already exist. Opening housings to take grease out, or sending samples to a laboratory, comes after that.
The shape of the symptom points to the cause. If the machine is heavy only at start-up and eases once running, look at the stiffness of the grease itself: base oil viscosity and consistency grade. In a centralised lubrication system, starving points far from the pump together with rising pump pressure point to cold pumping, and juddering only after a frost or a wash-down points to frozen water. If only the machines in cold spots run heavy among those on the same grease, look at a grease choice that does not suit the season.
If that does not settle it, run a control trial. Of two identical machines in the same location, put the candidate grease into one only and log starting current or lubrication pressure side by side on the same morning. Change one thing at a time: if a grease that changes both base oil viscosity and consistency grade brings improvement, there is no telling which change did it.
Confirm the result in numbers. On the next cold morning at the same temperature, compare starting current, lubrication pressure and whether grease reaches each point against the figures before the change, on the same basis. If needed, ask the supplier for the candidate grease's low-temperature torque or flow pressure results and set them against the actual minimum temperature at that location.
The hypotheses can overlap. A grease with thick base oil and a high grade, used regardless of season, fits three hypotheses at once, and changing that one grease can clear them together. Water, on the other hand, comes back after a grease change if its way in stays open. So where they overlap, close off the water first and then revisit the grease choice, because water has already altered the stiffness of a wet grease (Cyriac et al., 2016a) and the effect of a new grease cannot be compared fairly.
Limits and cautions
Suitable lowest operating temperature, consistency grade and base oil viscosity differ by bearing, load, speed and lubrication method, so numeric decisions follow the grease's TDS and the bearing and lubrication system makers' guidance. Mixing different greases can change their properties, so confirm compatibility with the supplier before any change. For safety-related equipment such as cranes and brake systems, do not change grease on floor judgement alone; get the equipment maker's approval.
Safety matters too. Turn stiff machines by hand or add grease only after the machine is fully stopped and locked out. Do not use a flame or torch to soften stiff grease; where heat is needed, use only methods the equipment maker allows. For greases and cleaning agents, wear protective equipment as the product's safety data sheet, the SDS, directs, and keep hands away from grease escaping under high pressure.
Sources
- Al-Quraan, T. M. A., Mikosianchyk, O., Yakobchuk, O., Mnatsakanov, R., Khimko, A., & Kostiunik, R. (2025). The effect of water on the tribological properties of aviation lubricants. Tribology in Industry, 47(3), 513–525. https://doi.org/10.24874/ti.1971.06.25.08
- ASTM International. (2020). ASTM D1478-20, Standard test method for low-temperature torque of ball bearing grease. https://store.astm.org/d1478-20.html
- ASTM International. (2021a). ASTM D217-21, Standard test methods for cone penetration of lubricating grease. https://store.astm.org/d0217-21.html
- ASTM International. (2021b). ASTM D4693-07(2021), Standard test method for low-temperature torque of grease-lubricated wheel bearings. https://store.astm.org/d4693-07r21.html
- ASTM International. (2024). ASTM D2270-24, Standard practice for calculating viscosity index from kinematic viscosity at 40 °C and 100 °C. https://store.astm.org/d2270-24.html
- Conrad, A., Hodapp, A., Hochstein, B., Willenbacher, N., & Jacob, K.-H. (2022). Low-temperature rheology and thermoanalytical investigation of lubricating greases: Influence of thickener type and concentration on melting, crystallization and glass transition. Lubricants, 10(1), 1. https://doi.org/10.3390/lubricants10010001
- Cyriac, F., Lugt, P. M., & Bosman, R. (2016a). Impact of water on the rheology of lubricating greases. Tribology Transactions, 59(4), 679–689. https://doi.org/10.1080/10402004.2015.1107929
- Cyriac, F., Lugt, P. M., & Bosman, R. (2016b). Yield stress and low-temperature start-up torque of lubricating greases. Tribology Letters, 63(1), 6. https://doi.org/10.1007/s11249-016-0693-8
- Delgado, M. A., Valencia, C., Sánchez, M. C., Franco, J. M., & Gallegos, C. (2006). Influence of soap concentration and oil viscosity on the rheology and microstructure of lubricating greases. Industrial & Engineering Chemistry Research, 45(6), 1902–1910. https://doi.org/10.1021/ie050826f
- Deutsches Institut für Normung [DIN]. (2016). DIN 51805-2:2016-09, Testing of lubricants – Determination of flow pressure of lubricating greases according to Kesternich method – Part 2: Automatic method. https://www.dinmedia.de/en/standard/din-51805-2/258258975
- Hodapp, A., Conrad, A., Hochstein, B., Jacob, K.-H., & Willenbacher, N. (2022). Effect of base oil and thickener on texture and flow of lubricating greases: Insights from bulk rheometry, optical microrheology and electron microscopy. Lubricants, 10(4), 55. https://doi.org/10.3390/lubricants10040055
- International Organization for Standardization [ISO]. (2003). ISO 6743-9:2003, Lubricants, industrial oils and related products, class L – Classification – Part 9: Family X, greases. https://www.iso.org/standard/23698.html
- Peskoe-Yang, L. (2020, December). Grease flow. Tribology & Lubrication Technology. Society of Tribologists and Lubrication Engineers. https://www.stle.org/files/TLTArchives/2020/12_December/Grease.aspx
- Yan, F., Sun, L., Wang, Z., & Zhu, R. (2020). Pressure drop analysis and prediction of wind power stations lubrication system based on CFD and GRNN. International Journal of Fluid Machinery and Systems, 13(1), 167–176. https://doi.org/10.5293/IJFMS.2020.13.1.167