BlogKaltec Voices
Why AI recommendations go through an engineer's check
- Type
- Kaltec Voices
- Published
- 24 November 2026
- Prepared by
- Jonghwan Moon
- Role
- Technical Staff
How deeply an AI recommendation is checked, and by whom, should follow what it costs when it is wrong. Checks thin out as the tool gets more accurate, and errors that surface late and are hard to undo, such as switching a refrigeration oil family, cost the most when they slip through.
Background
At the end of last month I gathered the hundred recommendations our technical team's recommendation tool had made over the month and counted, one by one, the ones the engineer in charge had changed before sending out. Twelve had been fixed. What caught my eye more than the number was where the fixes were. Recommendations like how many more cans of rust preventive spray to bring in, or when to take the next oil sample, went out almost untouched. The fixes were bunched in recommendations that changed an oil family or would mix one oil with another, and a few of those had been passed as-is by the first reviewer and caught by a different engineer at the next step.
AI recommendations are entering the technical support of suppliers and equipment vendors. That twelve recommendations needed fixing and where those twelve were bunched are two different pieces of information, and it is the second that tells you where to place the check. Not every recommendation needs a check of the same depth. Working on both field application and AI, this is the rule I hold to. An AI recommendation should get its depth of check, and the person who checks it, set by what it costs when it is wrong. When that cost is high, the check must not be thinned just because the tool has become more accurate.
Errors that surface late and are hard to undo
Get the top-up quantity for rust preventive spray wrong, and it shows on the stores shelf next week. If short, order once more. If over, skip the next order. The buyer who watches the shelf notices right away, and the cost of undoing it is a few cans of spray.
Refrigeration oil in a refrigeration compressor is another matter. Inside the compressor it dissolves in the refrigerant, travels the whole system and returns to the compressor, so the oil is chosen as a pair with the refrigerant. With the move to chlorine-free HFC refrigerants, mineral oil, which does not dissolve well in the new refrigerants, was pushed out and polar synthetic oils took its place. Most stationary refrigeration equipment in plants and buildings uses polyol ester, or POE, and most automotive air conditioning uses polyalkylene glycol, or PAG. Both oils readily absorb moisture, so they take a lot of care to handle (Canter, 2009). Even on the same HFC refrigerant, R-134a, the belt-driven open compressor in a vehicle air conditioner and the semi-hermetic compressor in a plant chiller use different oils.
One of the twelve I counted was at this very spot. It was choosing the oil for a semi-hermetic compressor in a process cooling chiller at an electronic components plant. The recommendation pulled in records from a vehicle air conditioning compressor on the same refrigerant as the closest case and came out with a PAG oil. In semi-hermetic and hermetic compressors, the motor sits inside the housing where refrigerant gas and oil circulate, so the oil's electrical insulating properties have to be weighed too. Automotive sources show well how much this matters when the motor sits in the oil. Electric compressors in hybrid vehicles use POE, and the service literature says that even 1% of ordinary PAG mixed in lowers its insulating properties and can damage the system, and that contamination means replacing much of the air conditioning hardware (I-CAR, 2015).
An error like this does not show on the day the oil goes in. It surfaces when oil return worsens or motor insulation drops and the compressor stops, and by then changing just the oil does not undo it. While the refrigerant is recovered and the system flushed, the process tied to that chiller stops too. On screen it is one line, just like the rust preventive spray recommendation. But weigh whether the error shows late, whether it can be undone once it shows and whether it reaches the customer's equipment, and the two recommendations sit at opposite ends. In the terms of failure mode and effects analysis, or FMEA, the tool's accuracy lowers only occurrence, and the depth of check is set by severity and detection.
Checks thin out as accuracy rises
I am often asked whether human checks can be cut once recommendations get more accurate. If the recommendations needing a fix drop from twelve to one, checking the other ninety-nine looks like waste. I do the sum differently. Against the checks you cut, you have to count how far the damage spreads if that one slips through. For refrigeration oil, that is one compressor and the process tied to the chiller.
People's tendency to lean on a machine's output is a long-studied topic in human factors. Parasuraman and Manzey reviewed the research in this field together. When an aid is imperfect, people miss what the aid missed and follow what it wrongly advised. They concluded that this automation bias shows in novices and experts alike, cannot be prevented by training or instructions alone, and is a matter of attention, not only judgment (Parasuraman & Manzey, 2010). The EU's Artificial Intelligence Act also writes this tendency into its human oversight article. High-risk AI must be built so the people overseeing it can stay aware of automation bias, the tendency to rely automatically or too much on its output, especially for systems that give recommendations people use to make decisions (European Union, 2024).
In checks on the floor, this tendency shows quietly. After a few weeks of correct recommendations, the checker stops opening the basis and just reads the conclusion line and moves on. In the hundred I counted too, the ones the first checker missed were recommendations whose conclusion line looked plausible, so the error showed only once you opened the basis. The more accurate the tool, the less people look, and a rare error that gets past the spot where people look less goes all the way into the compressor.
What keeps a check from becoming a formality
So I keep the depth of check apart from accuracy. Even as accuracy rises, I do not cut the check on recommendations involving a family change or mixing. Recommendations like top-up quantities no longer go through a person's hands each time. But a check step on paper does not make a check happen.
What keeps a check from stopping at formality is a hand that traces the basis back, and a place to stop. What caught the chiller case was not the tool's accuracy but an engineer who opened the record cited as the source and compared it, starting with the compressor type. That the basis record came from an open compressor in a vehicle air conditioner took a minute to see. So refrigeration oil recommendations that change the family are set to wait for an engineer's approval at the step before any customer document goes out.
The cost of one wrong recommendation cannot be fully priced at my desk. Even the same refrigeration oil recommendation costs differently on a line with a standby chiller and on a line where process cooling water stops when one unit goes down. That cost has to be priced by the maintenance staff who know that plant's equipment and production schedule. My part, as a supplier engineer, goes as far as laying out the facts on oil and refrigerant with their basis and stopping recommendations whose basis does not match the equipment's conditions.
Putting it to work
The first thing a plant starting to receive AI recommendations should do is sort the recommendations coming in by the cost of being wrong, and set the depth of check and who checks for each tier. I use three tiers.
The light tier is recommendations whose errors show at the next order or next round and cost a few consumables to undo. Rust preventive spray top-up quantities and the date of the next sample within a set interval belong here. They are not checked one by one. Once a month the buyer picks a few and compares them with actual usage and sampling records.
The middle tier is recommendations that show at the next scheduled inspection and can be undone but touch the equipment. Matching the viscosity grade of top-up oil within the same family and shortening the oil change interval belong here. One supplier engineer opens the basis, confirms the equipment in the basis record is the same type and approves. A recommendation to lengthen the change interval on critical equipment moves up a tier, since its error shows late, as wear.
The heavy tier is recommendations that surface late and need the system opened to undo. Changing a refrigeration oil family, changing the oil along with the refrigerant, and topping up with oil of another family so the two mix belong here. This tier needs no new procedure. It rides the plant's change management procedure. The supplier engineer and the maintenance staff responsible for that equipment look at it together, and for a chiller under a maker service contract, the maker's check is obtained too. What to look at is the current refrigerant and oil family, whether the compressor is open or semi-hermetic, and the oil list the compressor maker has approved. If the family changes, also decide how much of the old oil to drain, sealing and moisture control for the new oil, and replacing the filter drier and the first acid number check after the change.
Sort recommendations into tiers and it becomes clear that the accuracy figure sets the depth of check for no tier. The question left is who looks into the heavy-tier recommendations. If it is checked by an engineer who can trace the cited record back to compressor type and oil family, sitting with that plant's maintenance staff, it is a recommendation worth accepting.
Conclusion
The light tier is what changes. As the tool gets more accurate, many more recommendations like top-up quantities and sampling dates will go out without passing through a person's hands, and engineers' time will gather that much more on the heavy tier. Some things do not change. When one line on refrigeration oil is wrong, the system has to be opened, and the person who can price that cost stands in front of that equipment.
Even as making recommendations passes to machines, pricing the cost of being wrong and stopping a recommendation in front of it will stay with the people who know the equipment.
Sources
- Canter, N. (2009). Refrigeration lubricants: Transitioning to new refrigerants. Tribology & Lubrication Technology, 65(12), 30-39.
- European Union. (2024). Regulation (EU) 2024/1689 of the European Parliament and of the Council of 13 June 2024 laying down harmonised rules on artificial intelligence (Artificial Intelligence Act), Article 14. Official Journal of the European Union, L series.
- I-CAR. (2015, June 25). A/C on hybrid vehicles: What you need to know. I-CAR Repairability Technical Support. https://rts.i-car.com/crn-219.html
- Parasuraman, R., & Manzey, D. H. (2010). Complacency and bias in human use of automation: An attentional integration. Human Factors, 52(3), 381-410. https://doi.org/10.1177/0018720810376055