KALTECKOREA

BlogKaltec Voices

What to check in the first three months after delivery

Type
Kaltec Voices
Published
24 November 2026
Prepared by
Jaemin Seo
Role
Technical Staff

Whether a water-based cleaner delivered to an automotive parts washing line really fits shows in the second and third months, when building oil, leftover old cleaner and the turning season step in one after another. A supply that reads the line's log together at weeks 1, 4, 8 and 12 after delivery and adds tests on those days is what catches the changes of those three months.

Background

Eight weeks after we changed the water-based cleaner, I went to an automotive parts washing line for a check. At the rinse tank, the foam on the surface stood higher than at delivery, and a smell rose that had not been there before. Paging through the log the line keeps each week, I saw the wash tank's concentration and pH had stayed evenly within the range set at delivery. What had changed was the rinse tank. Its conductivity and foam height had risen every week from week 6, and conductivity was well above the value noted at delivery. The next process had not yet reported stains on washed transmission shafts. The wash tank held fresh fluid, but the rinse tank had not been emptied on changeover day. Yet new cleaner also builds up in a rinse tank over eight weeks, so rising conductivity alone could not say whether leftover old cleaner was to blame.

Whether a delivered cleaner fits a line does not all show in the first month. In the first month the fresh bath's reserve hides problems. From the second month the oil parts carry in and old cleaner left in corners of the equipment step in, and in the third month the turning season. An application succeeds or fails as much on what you measure again, and in which week, over the next three months as on the product chosen on delivery day.

Why the first month is quiet

A freshly filled wash tank starts in its best state. Concentration is set by titration on delivery day, the corrosion inhibitor and defoamer are intact, and there is almost no oil in the bath. A cleaner's life is taken to end when the soil the bath holds passes what it can hold, or when it can no longer keep removed soil from redepositing on parts (NEWMOA, 2003). The first month is the furthest point from that limit. Quiet first weeks may mean the product fits, or only that this reserve is still there. First-month records alone cannot tell the two apart.

How fast the reserve shrinks differs by washer, because the cutting oil parts bring from the previous process, the number of parts washed a day and the time the skimmer really runs all differ. With a cleaner that emulsifies oil and holds it, the skimmer removes only the floating oil, and the emulsified oil stays in the bath (NEWMOA, 2003). As that oil grows, cleaning power drops a little at a time over several weeks. Emulsified oil splits when cooled or made acidic (EPA, 1994). So I add acid to a sample to break the emulsion and read the separated oil in a graduated cylinder. Fresh fluid broken with acid also floats a surfactant layer, so the week 1 reading of broken fresh fluid is the zero. Even with steady first-month concentration, I look first at the washer where that amount grows each week.

Concentration also moves differently after the first month. In a heated washer, water evaporates, and cleaner leaves with the fluid carried out on parts. Some components volatilize at high temperature, and one source notes that losing them means restoring the cleaner's chemical balance (EPA, 1994). Where an automatic fill valve keeps the level and people add the cleaner, a run of busy weeks adds only water and concentration falls. The corrosion inhibitor thins with it, so washed parts rust more easily while they wait for rust-preventive oil in the next process.

Where old cleaner stays behind

On changeover day, the places that get less attention are outside the wash tank. Parts leave washing with a thin film of cleaning fluid and move on to rinsing (NEWMOA, 2003), so the rinse tank is where cleaner slowly builds up anyway. Overflow or scheduled changes keep that buildup in check, but if the rinse tank is not emptied on changeover day, the count starts from the old cleaner. Old cleaner stays in it, and new cleaner carried over mixes in. Piping to the spray nozzles, filter housings, heater surfaces and the overflow trough between wash and rinse tanks also hold old fluid easily.

Mixing matters because every cleaner has its own build of surfactants and defoamers. Spray washers use cleaners made with low-foaming detergents (NEWMOA, 2003), and where there is agitation, low-foaming nonionic surfactants are used (EPA, 1994). Low-foam nonionics foam little only in fluid warmer than their cloud point, so carried into a cooler rinse tank they can foam. A balance tuned within one product may break when mixed with another. Switch from an emulsifying alkaline cleaner to a neutral one that does not emulsify oil (NEWMOA, 2003), and oil held in the old fluid can split and float up where the two meet. So before a changeover I first ask the old cleaner's type and whether it emulsifies. If the pair is a worry, I empty the rinse tank the same day and fit new filters.

The season that turns within three months

Three months is about the length of one season. So on delivery day I first count on the calendar which season week 12 falls in. Change in July or August, and the first-month reserve is shorter from the start, because the bath runs hot.

Deliver in April or May, and within three months you meet the rainy season and early summer. How long washed parts take to air-dry depends on temperature and humidity, and parts that cannot dry fast can corrode (EPA, 1994). The same source notes that some ferrous materials show rust soon after contact with water and advises testing first. In the rainy season this shows first on washed parts stacked on racks waiting for assembly, and the same concentration gives different results in April and July. This is also when neutral baths run at low temperature warm up, bacteria grow and a smell begins.

Deliver in autumn, and you meet the first cold. Water-based cleaning works better the hotter it is (EPA, 1994), and in an unheated plant the heater takes longer to warm the bath, so first-shift parts are washed in fluid not yet up to temperature. On a bath cooled overnight floats an oil layer that summer never showed. Parts washed and dried, stored in an unheated warehouse, then moved into a warm assembly hall can collect condensation and rust.

Putting it to work

Concentration and pH, wash tank temperature, oil layer, foam height and rinse water conductivity are measured weekly by the line and written in each washer's log. What I set are four days to read that log together and add tests that are hard to run on site: weeks 1, 4, 8 and 12 after delivery. When you compare suppliers, get these dates, and what each will add, before delivery. Whether a supplier will come back on those days to read the log, you can tell before the contract by whether the dates are in the proposal.

Week 1 sets the baseline. For each washer, record titrated concentration and pH, rinse water conductivity and oil amount, along with the places that could not be emptied at changeover and who did the changeover that day. Also get from the next process's quality lead how they judge stains, rust and remaining oil on washed parts. At the end of the week the customer holds each washer's baseline and a list of places where old fluid may remain.

Week 4 looks at oil and top-ups. Add the oil read after breaking the emulsion with acid to the weekly oil layer records, to separate what the skimmer removes from what builds up in the bath. Set the cleaner addition records beside the method agreed at delivery and correct any gap here. Only then can changes at the next check be read as the product's share.

Week 8 is the second-month check. If a log steady through week 4 began to diverge in weeks 6 and 7, open first the old-fluid places noted in week 1. To tell old fluid from buildup of new fluid, refill the rinse tank and watch whether conductivity and foam climb again at the same slope. How far rinse water conductivity has risen from baseline shows the carryover from the wash tank, and a wash or rinse tank that smells gets culture slides for bacteria. Washed parts sit on the rack for the real waiting time, then are judged by the next process's standard. The customer receives each washer's oil and conductivity trends.

Week 12 is past the change of season. When comparing with the week 1 baseline, record that day's fluid temperature and workshop temperature and humidity, and hand the three months of logs over to the customer's checklist. This is also when to set when to change the cleaning fluid, from how cleaning power declined over the three months (IDEM, 2026).

Conclusion

An application can be called finished only after three months. Records steady in week 4 that diverge later cannot all be foreseen, however carefully you choose on delivery day. So choosing the product and measuring again over the three months after delivery belong together in one supply.

Days 7, 28, 56 and 84 after delivery: four checks.

Sources

  • Northeast Waste Management Officials' Association [NEWMOA]. (2003). Pollution prevention technology profile: Closed-loop aqueous cleaning. https://www.newmoa.org/wp-content/uploads/2022/07/Closed-Loop-Aqueous-Cleaning-2003.pdf Accessed November 2026.
  • U.S. Environmental Protection Agency [EPA]. (1994). Guide to cleaner technologies: Alternatives to chlorinated solvents for cleaning and degreasing, EPA/625/R-93/016. Office of Research and Development.
  • Indiana Department of Environmental Management [IDEM]. (2026). Pollution prevention and parts washers information sheet, Indiana Pollution Prevention Toolkit. https://www.in.gov/idem/prevention/files/p2_toolkit_parts_washer_info_sheet.pdf Accessed November 2026.

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.