BlogKaltec Voices
How general-purpose language models get chemistry questions wrong
- Type
- Kaltec Voices
- Published
- 24 November 2026
- Prepared by
- Byunghoon So
- Role
- ML / AI Engineer
General-purpose language models answer chemistry questions with confidence, giving numbers stripped of temperature and units, standards stripped of edition years, and equivalents and registrations that are on no list. The same model answers differently once source documents and equipment conditions go into the question, and the blanks that remain are filled by people who know the equipment.
Background
While reading past inquiries line by line to build an evaluation set, I stopped at one request-for-quote email. It came from an equipment engineer at a food plant, and one paragraph in the middle read differently from the rest. "As an equivalent to the screw compressor oil you currently use, we recommend the following product. Viscosity 46, H1 registered for food contact, excellent oxidation stability." It was a chatbot's answer pasted in as is. All three items are standard lines in compressor oil data sheets, so nothing looks wrong at first read. On a second read, the 46 had no temperature and no unit, and when I checked one registration body's public list, the recommended product was not on it.
I don't see this as a mistake models make now and then. General-purpose models get chemistry questions wrong in patterns. Conditions fall off numbers, editions are erased from standards, and names and registrations that are on no list get filled in plausibly. Knowing the patterns shows what to attach to a question, and which blanks stay empty even then.
Viscosity without temperature or units
A lubricant's viscosity grade goes by a single number, but that number carries conditions. ISO viscosity grade 46 for industrial lubricants means a kinematic viscosity at 40 °C between 41.4 and 50.6 mm²/s (ISO, 1992). Data sheets usually list kinematic viscosity at both 40 °C and 100 °C, and even a grade 46 mineral oil drops to a single-digit value at 100 °C. A 46 without its temperature cannot be compared. Units work the same way. Kinematic viscosity is dynamic viscosity divided by density, so the same 46 points to different oils in mPa·s and in mm²/s. For an oil with a density of 0.87, 46 mPa·s is about 53 mm²/s, outside the grade 46 range.
Models often drop these conditions for a reason. In the text they learned from, numbers and conditions often sit apart. In a data sheet table, temperature and unit appear once in the header and the values sit in the cells below, and on the plant floor people say "46 oil" with no conditions at all. So for a model, 46 stays a number often attached to compressors and hydraulic systems, and what was measured at what temperature does not stay with it. When an answer gives a viscosity, check first not the value but whether a temperature and unit sit next to it. The email's "excellent oxidation stability" is the same pattern. In a data sheet that spot holds a rotating pressure vessel oxidation test result in minutes; an "excellent" with no method and no value does not say what it was compared with.
Standards with the edition year erased
Standards and test methods get revised, and sometimes withdrawn. The year after an ASTM standard number is the year that edition was adopted or last revised. ASTM D2882, which assessed the wear characteriztics of hydraulic fluids with a vane pump, was withdrawn in 2003. ASTM named no replacement, and D7043, issued in 2004, took over the vane pump test under the same conditions. The current edition is from 2024. Yet the 2021 edition of D7043 still carried a passage pointing to the old D2882 (ASTM International, 2000, 2021, 2024). A withdrawal notice comes out once, but the data sheets, catalogs and papers that cited the method stay around for years. In the text a model has read, the withdrawn name can appear more often than the current one.
Edition years go missing for a reason in that text, too. Data sheets and catalogs often cite a standard by number alone, so for the model the number stays as the standard's name and the year does not. Asked about standards, a model often gets the number right and leaves out the year. In the evaluation set I built, most answers that cited a standard gave the number with no edition year. Training cutoff is a separate problem. Editions revised after it do not exist for the model, so even an answer with a year can be one edition behind. I have also seen chatbots with web search on cite an old catalog the search turned up instead of the current edition. A standard number without an edition year does not say which edition's limits it means, so it cannot be checked against the test reports you have on file.
Plausible equivalents and registrations that do not exist
The most dangerous pattern is names. The question "What is the equivalent of this product?" assumes an equivalent exists, and the model picks the most plausible name on that assumption. Product names mentioned together in similar texts come out, and the registration and approval fields that always appear in compressor oil data sheets get filled in too. The way models are trained and evaluated rewards a guess that might be right over saying "I don't know." One analysis finds that made-up answers are not a mysterious malfunction but classification errors that arise in training, and that this grading keeps them from going away (Kalai et al., 2025). In citations the pattern showed up in numbers. In an experiment that had models write short literature reviews, 55% of the citations from an earlier-generation model and 18% from the next generation pointed to works that do not exist (Walters and Wilder, 2023). Registration numbers and approval lists are, for a model, fields it can fill as plausibly as a citation. So an evaluation set should mix in questions built on false premises, such as whether a product passes a withdrawn test method, and count how often the model corrects the premise.
Tone cannot tell these errors apart. In a study that evaluated models on about 2,700 chemistry questions and compared part of them against chemists, the best model beat the best chemist in the study on average score, yet stalled on some basic tasks and made overconfident predictions (Mirza et al., 2025). A general-purpose model is like a passerby who gives directions with confidence. One who knows the way and one who doesn't sound exactly the same; the difference is whether they point to a signpost you can check. An H1 registration, for use where incidental food contact can occur, can be confirmed on the registration body's public list by product name and registration number (NSF International, n.d.). Still, missing from one list does not prove a product is unregistered. More than one body grants H1 registration, and the same oil appears on a list only once the seller registers it under its own name. An answer that cannot point to a signpost is not an answer yet.
In my work building answers from site records and chemistry documents, I have collected wrong answers and sorted them by pattern. Switching models cut how often they were wrong, but the patterns stayed the same. Attaching data sheets to the question noticeably cut errors in conditionless numbers and edition years. Even so, attaching a table-heavy PDF can split header temperatures and units from their values again. Errors in judging equivalence remained. They remain because equivalence is not settled by laying two data sheets side by side. It is settled by whether the oil leaves carbon and varnish at the discharge temperature of the equipment it goes into, and whether the company selling under the recommended name holds an H1 registration in its own name. So when we build an answer, we put the product data and that customer's site records in one place, and a technical specializt judges the blanks that remain.
Putting it to work
Here is an experiment you can run today with the chatbot you already use. First ask the usual way: "Tell me an equivalent for the oil in our plant's screw compressor." Save the answer, then rewrite the same question: "I am looking for candidates to replace the oil in the attached data sheet. Compare viscosity as kinematic viscosity at 40 °C in mm²/s, and give standards and test methods with their edition years. Give H1 registrations with registration numbers, and mark anything the attached documents do not confirm as unconfirmed. The equipment is an oil-injected screw compressor with a discharge temperature of ○○ °C." Run each question three times. Ask in a new chat every time, turn chat memory off and note which model you used.
Set the two answers side by side and count. How many numbers carry a temperature and unit, how many standard numbers carry an edition year, whether the recommended name stays the same across three runs, and how many fields say unconfirmed. In my runs, the second answer is shorter, its names change less and it has more unconfirmed fields. More unconfirmed fields does not make it a worse answer. It is the first answer that shows where the model does not know.
The fields still unconfirmed at the end are usually the two from earlier. The first lives in that equipment's operating records, the second in the registration number the seller provides, and neither is in the text the model read. So when you attach an AI-picked equivalent to a request for quote, the question is less whether the name is right than what fills these blanks. If the reply brings test reports with edition years, registration numbers and a test plan built on your equipment's conditions, the blanks are filled. If it brings just another name, they are still empty.
Conclusion
General-purpose language models are not ignorant of chemistry. What they don't know is your equipment's conditions, and where those conditions are missing they fill in the most plausible numbers and names. Numbers stripped of conditions, standards with erased editions and names on no list can largely be stopped by rewriting the question and attaching source documents. As models improve, errors in numbers and edition years will shrink, but judging equivalence will remain to the end, and its grounds lie not in the model but in equipment records and the seller's registrations.
The fields marked unconfirmed are the list of work to hand to a person.
Sources
- ASTM International. (2000). ASTM D2882-00, Standard test method for indicating the wear characteristics of petroleum and non-petroleum hydraulic fluids in constant volume vane pump. Withdrawn 2003. https://store.astm.org/d2882-00.html
- ASTM International. (2021). ASTM D7043-21, Standard test method for indicating wear characteristics of non-petroleum and petroleum hydraulic fluids in a constant volume vane pump. Superseded by the 2024 edition, D7043-24. https://store.astm.org/d7043-21.html
- ASTM International. (2024). ASTM D7043-24, Standard test method for indicating wear characteristics of non-petroleum and petroleum hydraulic fluids in a constant volume vane pump. https://store.astm.org/d7043-24.html
- International Organization for Standardization [ISO]. (1992). ISO 3448:1992, Industrial liquid lubricants: ISO viscosity classification. https://www.iso.org/standard/8774.html
- Kalai, A. T., Nachum, O., Vempala, S. S., Zhang, E. (2025). Why language models hallucinate. arXiv:2509.04664. https://arxiv.org/abs/2509.04664
- Mirza, A., Alampara, N., Kunchapu, S., et al. (2025). A framework for evaluating the chemical knowledge and reasoning abilities of large language models against the expertise of chemists. Nature Chemistry, 17, 1027–1034. https://doi.org/10.1038/s41557-025-01815-x
- NSF International. (n.d.). NSF nonfood compounds listings. https://info.nsf.org/USDA/Listings.asp
- Walters, W. H., Wilder, E. I. (2023). Fabrication and errors in the bibliographic citations generated by ChatGPT. Scientific Reports, 13, 14045. https://doi.org/10.1038/s41598-023-41032-5