Dosing more coagulant or polymer is the usual response to floc in the overflow, but if what is coming over is floc that has already formed, more chemical does not make it settle any better, and extra polymer can even make it lighter and fluffier. What actually lies behind it can be hydraulic overload, sludge floated by denitrification gas, sludge drawn off too late, light and fluffy floc from a polymer overdose, or poor coagulation, and often two or more at once.
Background
Brown floc slips over the overflow weirs around the clarifier in a steady line, and the water in the outfall channel is cloudy rather than clear. Some days lumps of sludge float here and there on the surface; other days there are no lumps, only small, light floc drifting over. The operator turns up the coagulant pump, but the next day the scene at the weir looks much the same.
Floc that carries over becomes suspended solids in the effluent and threatens the discharge limit, and if sand or membrane filtration follows, the load moves there and shortens the cleaning interval. In an activated sludge process, every bit of solids lost is lost biomass as well. When clarifier performance is reviewed, high effluent suspended solids fall into two broad cases: individual particles that will not settle are being discharged, or the sludge blanket at the bottom of the clarifier rises until it washes over the weir (Maine DEP, n.d.).
Whether a particle stays in a clarifier or leaves it is a contest between two speeds. The speed at which water rises towards the weirs is the incoming flow divided by the clarifier's surface area, the surface overflow rate, and any particle that settles more slowly than this is carried upwards and out (Tchobanoglous et al., 2014). So the causes of carryover come down to one of three things: the water rises too fast, the floc has become too light or too small, or sludge from the bottom has come up.
In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: line up the days and hours when floc carried over with flow, chemical dose and sludge withdrawal records, and compare them with the clarifier's design flow and the dosing range in the chemical's technical data sheet, the TDS.
Hypothesis 1: hydraulic overload
When carryover follows the flow, look at hydraulic load. That means heavy rain, times when production releases water all at once, periods when one clarifier is down for maintenance and the others take its flow, and moments when internal recycle flows such as return streams or filter backwash water come back together. On a rainy-season morning, inflow mixed with stormwater surges in at several times the usual rate, and the flow over the clarifier weirs visibly speeds up. Within an hour or so, floc starts going over evenly along the whole weir.
As flow rises, the surface overflow rate rises with it and detention time falls, so settling performance drops; peak industrial flows arriving all at once have the same effect (Moore, 2023). An activated sludge clarifier has one more problem. A clarifier both separates particles from the rising water and thickens sludge on the bottom, and when flow rises, the solids load coming in rises too, so the bottom's thickening capacity can hit its limit first (Ekama et al., 1997). Even when the sludge settles well, if too many solids are pushed in and not returned fast enough, the blanket rises and washes over the weir (Maine DEP, n.d.).
The first step is to overlay the carryover times on the flow record. If floc goes over only at high flow and stops when flow falls, this is the direction. Divide the flow at those times by the surface area of the clarifiers in service to get the surface overflow rate, and compare it with the design value. With several clarifiers, also check how much each one actually receives. Badly designed distribution structures, weirs that are not level, missing sections of weir and wrongly set influent gates all send water to one clarifier or one side of a weir (Moore, 2023).
If hydraulic load is the cause, put every available clarifier into service and move maintenance to seasons with lower peak flows. Shift internal recycle flows to other hours or send them elsewhere, and spread out water released all at once by production through an equalisation tank. Level the weirs and reset the distribution gates so each clarifier receives an even share. In activated sludge, the solids load entering the clarifier can also be cut for a while. Where the return system is not bringing solids back fast enough, raise the return rate and clean any clogged return line (Maine DEP, n.d.).
Hypothesis 2: denitrification gas
In activated sludge processes that nitrify well, especially in warm seasons, watch first for clumps rising to the surface. By afternoon, palm-sized clumps of sludge rise here and there on the clarifier surface, and up close small gas bubbles are lodged inside them. Clumps pushed towards the weirs break up and go over, while the water between them stays fairly clear.
Mixed liquor from a nitrifying process still contains nitrate. Sludge settled on the clarifier floor soon runs out of oxygen, and the bacteria in it breathe nitrate instead, turning it into nitrogen gas; this is denitrification. Nitrogen gas dissolves poorly in water, so it forms bubbles that cling to the floc, and sludge holding bubbles rises to the surface in clumps (Henze et al., 1993). A study of working plants found that denitrification in the clarifiers accounted for about 15 to 30% of the total denitrification in the process, and the authors judged that explaining it required modelling the sludge volume in the clarifier, which varied with the scraper interval (Siegrist et al., 1995). The longer sludge sits on the floor and the more nitrate is left, the more room there is for gas to form.
Scoop up a floating clump and press it to see whether bubbles burst, which tells it apart from the other hypotheses where even floc comes over rather than clumps. The easiest check is a settling test, letting mixed liquor from the end of the aeration tank settle in a 1 to 2 L cylinder (APHA, 2017), then leaving it for a few hours past the usual reading time. If sludge that settled well at first rises in clumps as time passes, it is denitrification. Also record nitrate nitrogen in the mixed liquor entering the clarifier and in the effluent, together with the return rate and blanket height.
If denitrification looks like the cause, cut both the time sludge spends on the floor and the nitrate entering the clarifier. Operating guidance notes that a slight increase in sludge wasting usually solves it, that the return rate sometimes needs raising, and that on-off aeration or an anoxic zone in the aeration tank lets denitrification happen in the aeration tank instead of the clarifier (Maine DEP, n.d.). Raising the return rate also raises the solids entering the clarifier, so check at the same time that the floor's thickening capacity is not exceeded. Confirm that the scrapers are running at their proper interval too.
Hypothesis 3: sludge drawn too late
Sludge builds up readily on the floor of clarifiers where the withdrawal pump runs only a few set times a day, where the withdrawal line often blocks, or where the scrapers stop and start. Sites that stop the withdrawal pump over holidays and restart it on Monday are the same. On the morning after a long weekend, a core sampler lowered to measure the blanket shows the sludge interface far higher than usual, and fine floc is mixed into the overflow near the weirs.
The sludge blanket on the floor sits at the bottom end of the path water takes on its way up and out. When withdrawal falls behind and the blanket thickens, its top comes closer to the weirs, and the rising flow easily lifts light floc from the top of the blanket. The blanket rising close to the surface and washing over the weirs is one of the two routes to high effluent suspended solids (Maine DEP, n.d.). Sludge that sits too long causes other problems too. For primary clarifiers, removing sludge more often or at a higher rate is listed as a remedy for floating sludge and septic conditions, and running collectors continuously is explained as a way to avoid overloading them with accumulated solids (Moore, 2023). In an activated sludge clarifier, sludge that lingers on the floor gives denitrification gas time to form.
Measuring blanket height directly is the core of the check. Measure it every day at the same spot and time with a clear core sampler or an interface detector, and record it, measuring before and after withdrawal as well. Look at the actual running time and flow of the withdrawal pump and the concentration of the withdrawn sludge, and make sure the line is not blocked so that the pump runs while no sludge comes out. Check scraper rotation and blade wear too. If the days the blanket rises match the days floc carries over, late withdrawal becomes the likely suspect.
If withdrawal has fallen behind, switch from a few long withdrawals to many short ones, and set a rule that withdrawal starts once the blanket passes a set height. Backflush lines that block on a regular schedule, and check that pump capacity and line velocity are enough to carry the sludge. Repair worn or broken scrapers, and set automatic operation so that withdrawal continues over holidays.
Hypothesis 4: polymer overdose
Where polymer dosing is set by hand, where the dose was not reset after influent quality changed, or where raw water turbidity fell but the dose stayed the same, check whether polymer is being overdosed. On an afternoon after the polymer pump was turned up a step or two because turbidity had risen, the floc in the flocculation tank grows visibly larger and swells like cotton wool. In the clarifier, though, this large floc does not go down to the floor; it drifts slowly at mid-depth and is carried to the weirs.
Polymer builds floc by linking particle to particle with its long chains, and floc linked this way has an open structure that becomes less dense and more porous as it grows (Hogg, 2013). Floc that has only grown in size and holds a lot of water settles poorly, whatever it looks like. Going above the right dose causes something else as well. Particle surfaces become covered with polymer so the chains have no free sites to attach to other particles, and with a charged polymer the particles' charge can be reversed so that they repel each other again, restabilisation, and flocculation gets worse rather than better (Bolto & Gregory, 2007). That is why polymer flocculation has a suitable dose range, above which more polymer does more harm.
Setting the dose record beside turbidity gives the first clue: if carryover began after the polymer dose went up, this is the direction. Confirm it with a beaker flocculation test, the jar test. On site raw water, keep the coagulant fixed and vary only the polymer over several steps to find the dose that gives the lowest overflow turbidity after settling. The jar test is the standard practice for determining the chemicals, doses and conditions for treatment (ASTM International, 2019). If the current dose sits above the best one and the overflow gets cloudier the higher it goes, it is an overdose.
If it proves to be an overdose, bring the dose down to the value found by jar test, and repeat the test to adjust the dose whenever raw water quality changes. Flow- or turbidity-paced dosing that makes the dose follow conditions overshoots less than hand setting. Mix fast and evenly where the polymer goes in, then stir slowly in the flocculation tank to grow floc, because once polymer attaches before it has spread evenly among the particles, further mixing cannot even it out and only breaks the floc (Hogg, 2013).
Hypothesis 5: poor coagulation
If the overflow is cloudy throughout and tiny pin-sized floc drifts scattered over the weirs, suspect the coagulation stage first. This appearance tends to come when water temperature falls in winter, when the pH or alkalinity of the raw water has changed, after the coagulant tank was switched to a new product, and when the actual output of the coagulant pump has dropped. A beaker dipped from the clarifier shows hardly any large floc, only fine particles throughout the water that do not settle after several minutes.
Most small particles in water carry a negative charge and repel each other, so on their own they do not clump. Aluminium and iron coagulants bring them together in two ways: positively charged hydrolysis products formed in the water neutralise the particles' negative charge, or an amorphous hydroxide precipitate forms and sweeps the particles into it, and which route dominates depends on pH and dose (Duan & Gregory, 2003). So when pH is outside the coagulant's working range or the dose falls short, particles stay under-neutralised and do not grow beyond small floc. Polymer's role is to link and enlarge the small floc formed first, so if coagulation upstream falls short, more polymer finds too little to link. This fits the explanation that destabilising particles with polymer alone takes an excessively high dose (Hogg, 2013).
Start by collecting the numbers for the coagulation stage. Measure pH right after coagulant addition, raw water alkalinity and temperature, and the coagulant pump's actual output, checking the pump by weighing what it delivers in a set time against its setting. If the coagulant product was changed, compare its active content with the TDS. In jar tests, fix the polymer and vary coagulant dose and pH. If adding coagulant or adjusting pH clearly clears the overflow, coagulation is short.
If coagulation fell short, fix the upstream stage before touching the polymer. Add acid or alkali to bring pH into the range found by jar test, and reset the coagulant dose for the raw water quality. Run jar tests more often in seasons when water temperature falls, and measure the coagulant pump's actual output on a schedule. When changing products, compare the two in jar tests on the same raw water before switching.
Finding the cause
The five hypotheses can be narrowed a long way with records and simple measurements. Flow and dosing records already exist, and blanket height and coagulation pH take minutes to measure. Settling tests and jar tests take hours, so they come next, and things that can only be seen with the clarifier drained, such as distribution structures or scrapers, are left for last.
The look of what is coming over is the biggest clue. First tell apart a whole blanket rising and washing over from individual particles escaping (Maine DEP, n.d.). Clumps holding gas bubbles rising to the surface point to denitrification gas, and a blanket risen near the weirs points to late withdrawal or hydraulic overload. Large, cotton-like floc drifting at mid-depth points to a polymer overdose, and pin floc with cloudy water to poor coagulation.
Timing points to the cause as well. Look first at hydraulic load if it coincides with high-flow hours, at denitrification if bubbly clumps increase in warm seasons, at withdrawal if it follows a holiday or a pump stoppage, at polymer if it comes right after a dose increase, and at coagulation if it follows a change in water temperature or raw water quality. These links only show if the carryover times are recorded, so log the time and appearance in the operating diary on every day it happens.
If that does not settle it, test. On the same day, run a settling test on mixed liquor to see whether the sludge settles well and whether it rises after a few hours, and run jar tests on raw water stepping coagulant and polymer separately to see which side of the best dose the current dose sits on. If the tests look good but carryover happens only in the plant, look at how the clarifier itself is run: flow, distribution and withdrawal. Change one operating setting at a time, and confirm the effect with effluent suspended solids or overflow turbidity.
Causes overlap easily. When hydraulic load overflows on a rainy day, solids are pushed in with it and the blanket rises, and in a nitrifying process the higher, lingering blanket can also make denitrification gas. Raising polymer because turbidity went up stacks an overdose on top of poor coagulation. In such cases, put the clarifier's physical conditions right first, flow distribution and sludge withdrawal, then reset coagulant and polymer doses in that order by jar test, because while water is overflowing and the blanket is high, the effect of changing chemicals cannot be compared fairly.
Limits and cautions
Suitable values for surface overflow rate, blanket height, return rate and chemical dose depend on the clarifier's type and size, the water being treated and the chemicals used, so numeric decisions follow the design data, the chemical TDS and the supplier's guidance. Biological causes such as poor activated sludge settleability or filamentous bulking are separate work needing microscopy and process diagnosis. Structural changes to the clarifier or its distribution are decided with a design engineer, and if a discharge limit may be exceeded, notify the authority as required.
Safety matters too. Handle coagulants and pH adjusters with protective equipment such as goggles and gloves, following the product's safety data sheet, the SDS. When measuring the blanket or cleaning weirs from above the clarifier, check the handrails and life-saving equipment and do not work alone. Gases such as hydrogen sulphide can build up in clarifiers with septic sludge and in covered channels, so follow confined space procedures and test the atmosphere before entering.
Sources
- American Public Health Association [APHA], American Water Works Association, & Water Environment Federation. (2017). Standard methods for the examination of water and wastewater (23rd ed.), Method 2710: Tests on sludges. APHA Press.
- ASTM International. (2019). ASTM D2035-19, Standard practice for coagulation-flocculation jar test of water. https://store.astm.org/d2035-19.html
- Bolto, B., & Gregory, J. (2007). Organic polyelectrolytes in water treatment. Water Research, 41(11), 2301–2324. https://doi.org/10.1016/j.watres.2007.03.012
- Duan, J., & Gregory, J. (2003). Coagulation by hydrolysing metal salts. Advances in Colloid and Interface Science, 100–102, 475–502. https://doi.org/10.1016/S0001-8686(02)00067-2
- Ekama, G. A., Barnard, J. L., Günthert, F. W., Krebs, P., McCorquodale, J. A., Parker, D. S., & Wahlberg, E. J. (1997). Secondary settling tanks: Theory, modelling, design and operation (IAWQ Scientific and Technical Report No. 6). International Association on Water Quality.
- Henze, M., Dupont, R., Grau, P., & De la Sota, A. (1993). Rising sludge in secondary settlers due to denitrification. Water Research, 27(2), 231–236. https://doi.org/10.1016/0043-1354(93)90080-2
- Hogg, R. (2013). Bridging flocculation by polymers. KONA Powder and Particle Journal, 30, 3–14. https://doi.org/10.14356/kona.2013005
- Maine Department of Environmental Protection. (n.d.). Troubleshooting activated sludge processes. Retrieved November 2026. https://www1.maine.gov/dep/water/wwtreatment/troubleshooting_guide.pdf
- Moore, L. W. (2023, August 24). Primary clarifiers [Slides]. EPA Operator Webinar Series, U.S. Environmental Protection Agency. https://www.epa.gov/system/files/documents/2023-09/230824_primary-clarification-for-operators_slides.pdf
- Siegrist, H., Krebs, P., Bühler, R., Purtschert, I., Rock, C., & Rufer, R. (1995). Denitrification in secondary clarifiers. Water Science and Technology, 31(2), 205–214. https://doi.org/10.1016/0273-1223(95)00193-Q
- Tchobanoglous, G., Stensel, H. D., Tsuchihashi, R., & Burton, F. (2014). Wastewater engineering: Treatment and resource recovery (5th ed.). McGraw-Hill Education.