KALTECKOREA

BlogApplication notes

Why can workers not stay long when cleaning with solvent in confined spaces?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Cleaning & Surface Prep

Rotating workers more often or looking for a milder-smelling product is the usual response when solvent odour becomes unbearable in a confined space, but the strength of a smell is a poor guide to vapour concentration, and the conditions that create the vapour stay the same. What actually lies behind it can be a volatile solvent containing aromatics, too little ventilation, liquid broken into fine spray droplets, too much solvent used, or heavy vapour pooling low, and sometimes two or more at once.

Background

Climb into a tank or the pit under a machine and start wiping off grease with solvent, and within minutes the smell thickens and the head feels heavy. The worker climbs out of the manhole for air and the next one goes in, and with that rotation a quick job drags on and on. When complaints about the smell keep coming, the cleaning itself tends to get postponed.

Time is not all that is lost. Breathing in a lot of organic solvent over a short time can impair manual dexterity, reaction speed and balance, and at higher concentrations it can depress the central nervous system to the point of unconsciousness (NIOSH, 1987). In an enclosed place such as a tank, even a solvent of low toxicity can have anaesthetic or asphyxiating effects if enough is used, and most serious incidents at solvent cleaning tanks have happened while the tanks were being cleaned out or the solvent replaced or topped up (HSE, 2015). Dizziness on a ladder or in a tight gap can lead to falls and entrapment, and since most hydrocarbon solvents burn, a build-up of vapour raises the fire risk as well.

A confined space has limited openings for entry and exit, unfavourable natural ventilation, and is not designed for continuous occupancy (NIOSH, 1979). Vapour concentration in such a place is set by the balance between how much solvent evaporates into it and how much leaves as the air is replaced. Models of inhalation exposure use the same frame, breaking exposure into factors such as how readily a substance gets into the air, the emission an activity creates, dilution and local extraction, and where the worker is and how they work (Tielemans et al., 2008).

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: check the composition, vapour pressure, flash point and exposure limits in the cleaner's safety data sheet, the SDS, then write down the size and openings of the space, the ventilation equipment, how much is used at a time and how it is applied, and how long the work lasts, and compare the two.

Hypothesis 1: volatile aromatics

Look at this hypothesis first where cleaners or thinners containing aromatic hydrocarbons such as toluene or xylene are used because they cut grease well, where general-purpose cleaners are bought without knowing their make-up, and where a fast-drying cleaner has been chosen deliberately. It shows more at higher temperatures, in summer or inside warm equipment. Take a shutdown day when a worker goes into a gearbox casing with the usual fast-drying cleaner. Before a few wipes with the wet rag are done, a sweetish smell fills the casing, and the worker pushes their head outside, saying their eyes sting.

How fast and how thick the vapour builds is first set by vapour pressure. Vapour pressure is a liquid's drive to escape into the air, and vapour pressure divided by atmospheric pressure gives the highest concentration that solvent can reach in air, its saturation concentration. The larger the vapour hazard ratio, the saturation concentration divided by the exposure limit, the easier it is to exceed the limit under the same conditions (Popendorf, 1984). Toluene has a vapour pressure of 21 mmHg and a recommended exposure limit of 100 ppm as an 8-hour average, and it can cause eye and nose irritation, dizziness, headache and confusion (NIOSH, n.d.). Since 21 mmHg is about 3% of atmospheric pressure, trapped air approaching saturation could in principle reach hundreds of times that limit. The faster a solvent evaporates, the sooner the air moves towards saturation during wiping, and the worker feels it first as smell and irritation.

The first check is on paper. In the SDS composition table, look for aromatics such as toluene, xylene and ethylbenzene, or naphtha containing aromatics, and note the vapour pressure, boiling range and exposure limits. Comparing vapour pressure divided by exposure limit against other candidates for the same job shows in numbers which choice weighs heavier in vapour terms. During the work, measure concentration at the worker's breathing height with a direct-reading gas meter and record how it compares with the exposure limit.

If the cause narrows to a volatile aromatic solvent, substitution is the surest route. With the cleaner supplier, pick a candidate that removes the same soil with lower vapour pressure and a higher exposure limit, a smaller vapour hazard ratio, and test whether a water-based cleaner will do. A lower vapour pressure solvent takes longer to dry, though, so agree the time before the next job as well. If substitution cannot happen at once, put the ventilation and quantity measures below in place first.

Hypothesis 2: poor ventilation

Suspect ventilation in a tank with only one manhole open, when a blower has been brought in but its duct ends near the entrance, when the blower draws in surrounding air that already carries vapour, and when exhaust drifts from the manhole back inside. Sketch the scene: a blower stands at the manhole with a short duct hung inside, but almost no air reaches the far corner where the worker is wiping. It is cool in front of the duct, and a few steps further in the smell is unchanged.

Ventilation's job is to bring in fresh air that dilutes the vapour the work creates and carries it out. That air must be drawn from an uncontaminated point, and the method chosen with the layout of the space, the position of openings and the properties of the contaminant in mind, so that air actually circulates (HSE, 2014). Where the work itself creates a harmful atmosphere, as with painting or the evaporation of residual chemicals, continuous ventilation must be kept up and contaminated air prevented from recirculating (NIOSH, 1979). The air needed for dilution rises with the rate at which vapour is released and falls with the concentration allowed, and more is needed the less evenly the air mixes (ACGIH, 2019). When incoming air cannot keep pace with the vapour released, concentration only climbs for as long as the work goes on.

Follow the path of the air. Check that the blower intake draws clean air, that the duct reaches the work position, that it is not kinked or crushed, and where the exhaust goes. A smoke tube or a light ribbon at the work position shows by eye whether the air actually moves. Measuring concentration in turn at the duct mouth, at the work position and in the far corner shows in numbers where the air does not reach.

If air is short or circulating in the wrong place, rework the ventilation layout. Bring the duct to the work position, take fresh air from an uncontaminated point and send exhaust where it cannot re-enter. Combine supply and extraction so that air sweeps across the space, and move the duct whenever the worker moves. Work out the required airflow with whoever looks after ventilation, based on the solvent and quantity in use.

Hypothesis 3: spray atomisation

Look at the application method where cleaner is sprayed with a sprayer or compressed-air gun to cover large surfaces quickly, where solvent is put through a pressure washer, and where aerosol cans wet places hands cannot reach. All the more so if complaints rose right after rag wiping was switched to spraying. In front of a worker wetting grease on a pit wall with a sprayer and scrubbing it with a brush, each burst raises a faint mist that hangs for a moment and then vanishes. The closer to the face it is sprayed, the more the smell arrives all at once.

What sets spraying apart is surface area. Breaking liquid into fine droplets greatly enlarges the liquid surface exposed to air, and this airborne evaporating area is usually far larger than the surface being cleaned. With a high vapour pressure solvent, the whole spray cone can be taken as saturated with vapour as it leaves the nozzle, and inhaling the droplets themselves adds to exposure (Fraunhofer ITEM, 2018). The same happens on the fire side. Heating or spraying solvent increases the risk significantly, and even a high-flashpoint solvent sprayed under high pressure can ignite far more readily than it does in bulk (HSE, 2015). Vapour that came off slowly from a rag is released in a short burst by spraying.

Whether spraying is the cause shows when the same job is done both ways. Clean the same area once by spraying and once with a wet rag, logging concentration at breathing height with a direct-reading meter, and compare the peaks and averages. Note also whether visible mist forms during spraying, how close the nozzle comes to the worker's face, and what spray pressure is used.

If the spray readings are clearly higher, change how the cleaner is applied. Apply solvent with a rag or brush, and see whether pre-moistened wipes or a paintbrush can take over. If spraying is a must, lower the pressure, use a nozzle that gives coarser droplets and set the working posture so the spray never points towards the face. Avoid high-pressure spraying of flammable solvent inside a confined space, and where it is truly needed, do it only with suitable equipment and explosion-protected conditions in place.

Hypothesis 4: too much solvent

Quantity may be the problem where cleaner is carried in by the bucket or open drum, where sodden rags are piled on the floor, and where leftover solvent stays inside in its container while workers come out for a break. The same applies when a large area is wetted all at once and then wiped section by section. Sloshing solvent across a wide tank floor a scoop at a time and working it with a squeegee is one such job. While the whole floor glistens, an open drum and a heap of wet rags sit beside the worker.

Evaporation happens wherever liquid is exposed to air, so the wetted area and the amount of open solvent are the very source of vapour. That is why models of inhalation exposure treat the emission an activity creates and surface contamination as separate, independent factors in exposure (Tielemans et al., 2008). In a confined space this supply simply accumulates. In places like tanks, even a solvent of low toxicity can have anaesthetic or asphyxiating effects if enough of it is used (HSE, 2015). For the same airflow, doubling the rate at which vapour is released raises the diluted concentration by the same proportion, so using less solvent works just like adding ventilation (ACGIH, 2019).

Two numbers do the checking. Measure how much cleaner one job used, as the difference between what went in and what came out, and set it against the area cleaned. Photograph the open containers, wet rags and pooled solvent left inside during the work as well. Then clean the same area again using only a measured portion and compare how concentration changes on the meter.

If quantity is the cause, keep the solvent inside the space to a minimum. Take in only what is needed in small lidded containers, close lids between uses, and put spent rags straight into a lidded metal bin and take them out. Wet large areas section by section and wipe each straight away rather than wetting everything at once. Pre-moistened wipes can be a practical way to use less, and if large quantities are still needed, another cleaning method is likely the better choice (HSE, 2015).

Hypothesis 5: vapour pooling low

Ask whether vapour is pooling when the work is in low places where air lingers: tanks with a manhole only at the top, dished pits and sumps, compartments split by baffles, deep troughs under machines. A telling remark is that the air seems fine higher up but the smell rises sharply the moment someone kneels or crouches. A worker cleaning around the drain in a machine pit starts standing, then kneels to reach a corner and says the smell suddenly got much stronger. The supervisor standing above the pit notices little.

Toluene vapour is about 3.1 times heavier than air (NCBI, n.d.). Vapours heavier than air stay in depressions and flow to low points where they are hard to remove, and inside tanks or underground structures they can linger for hours or even days after opening (NIOSH, 1979). Once vapour is well mixed and diluted with air the weight difference shrinks, but close to a floor with almost no air movement, dense vapour just above an evaporating liquid surface can flow downhill and collect before it disperses. Air quality inside a space can therefore differ from place to place, and remote or low-lying compartments and isolated pockets need separate thought when choosing ventilation (HSE, 2014).

The key to checking is measuring at several heights. Hang a direct-reading meter on a long hose or line and measure in turn at standing height, knee height and just above the floor, then in corners, at drains and beyond baffles. Clearly higher readings near the floor mean vapour is pooling. Record too whether symptoms worsen when workers get low and whether the work position coincides with the lowest point of the pit.

If vapour pools low, move the extraction low. For a small tank with only a top manhole, extracting from the bottom with a duct while make-up air enters through the manhole may be enough, and in every case the duct should reach the bottom so heavy vapour is removed (HSE, 2014). Clear pooled solvent from drains and sumps first, and where workers must lie low for long, place an extraction duct right in front of them. Lay the duct so it never blocks the way in or out.

Finding the cause

There is no need to investigate all five hypotheses at once. Rule them out starting with the easiest to check. The composition and vapour pressure in the SDS, the quantity used at a time and the method of application are known straight away from paperwork and watching the work. The airflow path and concentrations at different heights need a meter carried inside, so they come next.

The way symptoms appear points the direction. Strong smell and irritation right after entry point first to the solvent's volatility and composition. Symptoms that worsen steadily over time mean the airflow cannot keep up with the vapour; a smell that surges with every burst of spray points to spraying; and trouble only when a large area is wet points to the quantity used. Symptoms only when getting low or in corners point to vapour pooling near the floor.

If that still does not settle it, run control trials. In the same space on the same area, change one thing at a time: spray to rag, open drum to small lidded container, a duct hung at the entrance to one brought to the work position and down to the floor. Each time, measure concentration at breathing height and floor level in the same way. Change two things together and there is no telling which one worked.

Confirm last of all with measurements, not smell. After the changes, measure concentration over the work period with personal sampling or a direct-reading meter, compare it with the exposure limit, and see whether workers can complete the planned time without breaks. Smell alone cannot decide it. A study comparing odour thresholds with exposure limits for 214 industrial chemicals found some that can be smelt far below their limit and others that only become noticeable close to it (Amoore & Hautala, 1983). Continued exposure to the same smell also brings adaptation, a fall in perceived intensity (Dalton, 2000), so a report that the smell is weaker may not mean the concentration has dropped.

The hypotheses often overlap. If a volatile solvent is sprayed in quantity while the duct hangs only at the entrance, fixing any one of them alone will not bring the concentration down enough. In such cases, cut back the side that creates vapour first, meaning the choice of solvent, the quantity and the method of application, then deal with what remains by ventilation. Only when less vapour is released does the airflow needed come down to a practical size.

Limits and cautions

Exposure limits, required airflow and instrument settings differ with the solvent's make-up and the shape of the space, so numbers follow the cleaner's SDS and an industrial hygienist's assessment. Confined space work falls under legal procedures. Before entry, test the atmosphere for oxygen, then flammable gases and vapours, then toxic substances, and follow the procedure for permits, an attendant and a rescue plan (OSHA, n.d.). Never skip these steps because the smell seems bearable, and leave the required measurement and assessment to qualified people.

Watch fire risk and protective equipment too. Toluene has a flash point of about 4°C and can ignite at 1.1% in air (NIOSH, n.d.), so in a confined space where aromatic solvents are in use, keep out flames, static and electrical equipment that is not explosion-protected. Respiratory protection is the last resort, covering what ventilation and substitution cannot, and where oxygen may be short or the concentration is unknown, supplied-air equipment may be needed. Anyone who feels dizzy or gets a headache should come out at once, and no one should go in without protection to rescue a collapsed worker.

Sources

  1. American Conference of Governmental Industrial Hygienists [ACGIH]. (2019). Industrial ventilation: A manual of recommended practice for design (30th ed.). ACGIH.
  2. Amoore, J. E., & Hautala, E. (1983). Odor as an aid to chemical safety: Odor thresholds compared with threshold limit values and volatilities for 214 industrial chemicals in air and water dilution. Journal of Applied Toxicology, 3(6), 272–290. https://doi.org/10.1002/jat.2550030603
  3. Dalton, P. (2000). Psychophysical and behavioral characteristics of olfactory adaptation. Chemical Senses, 25(4), 487–492. https://doi.org/10.1093/chemse/25.4.487
  4. Fraunhofer ITEM. (2018). Experimental assessment of inhalation and dermal exposure to industrial spraying products during industrial and professional spraying activities (PROC 7 and PROC 11). Cefic. https://www.esig.org/wp-content/uploads/2018/08/Cefic_ESIG_Spray_Report_June-2018.pdf
  5. Health and Safety Executive [HSE]. (2014). Safe work in confined spaces: Confined Spaces Regulations 1997, Approved Code of Practice and guidance (L101, 3rd ed.). HSE Books. https://www.hse.gov.uk/pubns/books/l101.htm
  6. Health and Safety Executive [HSE]. (2015). Immersion and cold cleaning of engineering components (Engineering Information Sheet No. 21, rev. 1). https://www.hse.gov.uk/pubns/eis21.pdf
  7. National Center for Biotechnology Information [NCBI]. (n.d.). PubChem compound summary for CID 1140, toluene. Retrieved November 2026. https://pubchem.ncbi.nlm.nih.gov/compound/1140
  8. National Institute for Occupational Safety and Health [NIOSH]. (1979). Criteria for a recommended standard: Working in confined spaces (DHHS (NIOSH) Publication No. 80-106). https://www.cdc.gov/niosh/docs/80-106/
  9. National Institute for Occupational Safety and Health [NIOSH]. (1987). Current Intelligence Bulletin 48: Organic solvent neurotoxicity (DHHS (NIOSH) Publication No. 87-104). https://www.cdc.gov/niosh/docs/87-104/
  10. National Institute for Occupational Safety and Health [NIOSH]. (n.d.). NIOSH pocket guide to chemical hazards: Toluene. Retrieved November 2026. https://www.cdc.gov/niosh/npg/npgd0619.html
  11. Occupational Safety and Health Administration [OSHA]. (n.d.). 1910.146, Permit-required confined spaces. U.S. Department of Labor. Retrieved November 2026. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.146
  12. Popendorf, W. (1984). Vapor pressure and solvent vapor hazards. American Industrial Hygiene Association Journal, 45(10), 719–726. https://doi.org/10.1080/15298668491400494
  13. Tielemans, E., Schneider, T., Goede, H., Tischer, M., Warren, N., Kromhout, H., Van Tongeren, M., Van Hemmen, J., & Cherrie, J. W. (2008). Conceptual model for assessment of inhalation exposure: Defining modifying factors. Annals of Occupational Hygiene, 52(7), 577–586. https://doi.org/10.1093/annhyg/men059

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.