KALTECKOREA

BlogApplication notes

Why does the spray washer overflow with foam?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Cleaning & Surface Prep

Pouring in defoamer is the usual response when a spray washer overflows with foam, but defoamers lose strength as they work, so unless the condition that makes the foam changes, it tends to rise again. What actually lies behind it can be a high-foaming cleaner, a bath below the cloud point, cutting fluid drag-in, over-concentration or air drawn in, and sometimes two or more at once.

Background

Not long after the spray washer starts, white foam pushes out through the door seals and the exhaust, spills over the tank lid and runs down to the floor. Production stops while the machine is shut down to clear it, cleaning solution leaves with the overflow, and the floor turns slippery. When foam reaches the pump, spray pressure surges, the liquid from the nozzles sputters, and cleaning itself turns uneven.

Foam is a mass of air bubbles separated by thin liquid films. Pure water cannot hold foam for long; a component that gathers at the film surfaces, such as a surfactant, is needed for the films to hold and the foam to last (Pugh, 1996). A spray washer is a demanding machine for such a liquid. The pump draws cleaning solution up and sprays it through the nozzles, liquid that strikes the parts falls back into the tank, and the cycle repeats without pause. Liquid that falls fast and strikes the surface drags air down with it (Biń, 1993), so with only a little extra foam-supporting material in the solution, foam builds quickly.

So foam control in spray cleaning depends jointly on the cleaner's make-up, the bath temperature, the concentration, incoming contamination and the paths by which air gets in. Defoamers break foam, but oil-based defoamers lose their strength in the course of breaking it (Denkov, 2004). That is why pouring in defoamer at each overflow does little to stop the next one.

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: compare the intended use, operating temperature and concentration in the cleaner's technical data sheet, the TDS, with the actual values on the washer, and log the time of each overflow with the bath temperature, liquid level and incoming parts at that moment.

Hypothesis 1: high-foaming cleaner

Look at this hypothesis first when a cleaner used in an immersion tank or for hand washing has been carried straight over to a spray washer, or just after a change of cleaner for price or supply reasons. The same goes for a changed product number from the same supplier, or a general-purpose cleaner newly mixed in. Take the day a new spray washer arrived and the cleaner from the immersion tank next to it was poured in as it was. Within minutes of starting the pump, the parts seen through the window disappear behind foam, and the foam stays even after the solution has warmed up.

How readily foam forms and how long it lasts depends heavily on the type of surfactant. When surfactant packs tightly at the film surface, and surfactant from around a stretched, thinning spot is pulled in to heal it, the film does not burst easily (Pugh, 1996). Nonionic surfactants made by adding ethylene oxide behave differently. They make almost no foam at high temperature, which has been explained by the solution splitting in two above the cloud point and the surfactant-rich droplets that form breaking the films like a defoamer (Bonfillon-Colin & Langevin, 1997). This is a property a cleaner can rely on to keep foam low where foam is unwelcome, as in spray cleaning, and immersion or hand-wash products may have been made without weighing these conditions at all.

Open the TDS first. See whether it says spray use and whether the recommended temperature matches the washer's, and if it is not a spray product, this hypothesis is strong. Next, half-fill a clear bottle with the bath solution, bring it to wash temperature, shake it, and compare foam height and collapse time with freshly made solution at the same concentration. The standard foaming-power test measures the foam volume made by letting the solution fall from a set height onto its own surface, which resembles sprayed liquid falling back into the tank and makes it useful for comparing cleaners (ISO, 1975).

If the cleaner is wrong, switching to a low-foam spray cleaner is the real fix. Use defoamer only to bridge the gap until the switch. When changing, drain everything, run water through the tank and pipework once, then refill, so that old cleaner left behind does not blur the foaming behaviour of the new one. Assign storage and top-up duties so that no other cleaner gets mixed in.

Hypothesis 2: below the cloud point

Suspect bath temperature when a cleaner that has always behaved well foams over only right after the morning start-up, in winter, during a heater fault, or after the set point was lowered to save energy. Spraying breaks the liquid into fine droplets that meet the air, so on a washer with a weak heater the bath can cool while it runs. Follow one shift through. With heater and pump switched on together at the start of work, foam covers the window for a while and squeezes out round the lid. As the solution warms, the foam shrinks, and by lunchtime all is quiet as if nothing had happened.

The key is the cloud point. An aqueous solution of a nonionic surfactant made with ethylene oxide splits into two liquid phases and turns cloudy at a certain temperature; that is the cloud point, and it rises with the amount of ethylene oxide attached (ISO, 1991). Below the cloud point the surfactant is dissolved and supports the films like any other surfactant. Above it, surfactant-rich droplets form separately and act as a defoamer that breaks the foam (Bonfillon-Colin & Langevin, 1997). An oil droplet bridging the two surfaces of a film and then tearing it is a typical way a defoamer breaks foam (Denkov, 2004). A cleaner that relies on the cloud point to hold foam down therefore loses that hold whenever the solution is colder than its cloud point.

Put foam and temperature in one table. Measure the bath temperature near the pump suction, and record both the temperature when foam overflowed and the temperature when it settled. The cleaner's cloud point or low-foam temperature range is in the TDS or available from the supplier. Warming a bottled sample slowly and noting when it turns cloudy gives a rough idea of the cloud point, and the formal methods are set out in a standard (ISO, 1991). If overflows cluster below that temperature, this hypothesis holds.

If temperature is the cause, change when spraying begins. Set the work order so the heater comes on first and the pump runs only once the solution reaches its set temperature, and where possible tie the pump start to a temperature condition. If the bath cools during running, look at heater capacity, lid and insulation, and exhaust rate together. If the washer must run cool, choose a spray cleaner with a cloud point below that temperature with the supplier.

Hypothesis 3: cutting fluid drag-in

Weigh this hypothesis on lines where parts machined with water-miscible cutting fluid go straight into the washer without being drained. Cells with a washer right behind the machine tool, recessed parts that hold fluid, and machining lines that changed cutting fluid are typical. Sometimes the cleaner and temperature are unchanged, yet foam piles high only on days when parts from one machine go in. The solution turns more milky by the day, and after a fresh fill it stays quiet for a few days before the foam climbs again.

Water-miscible cutting fluids contain emulsifiers and other surfactants to keep oil evenly dispersed in water, and that make-up changes in service (Brinksmeier et al., 2015). When fluid on the parts enters the wash tank, these emulsifiers build up in the cleaning solution, and since the cleaner's foaming behaviour was designed around its own ingredients, emulsifiers from outside are not part of that calculation. Emulsified oil droplets also affect foam. In a study of foams made from emulsions, oil droplets slowed the drainage of liquid from between the films and made the foam last longer, with the effect varying by oil type and droplet size (Koczo et al., 1992). Oil droplets that break through to the film surface can do the opposite and break foam, so which way incoming oil will act is hard to predict (Denkov, 2004).

The clue comes from matching the foam log against incoming parts. See whether foam coincides with a particular machine, part number or the date the cutting fluid changed, and whether the solution has turned milky or carries oil on the surface. The bottle test narrows it a long way. Shake used solution and freshly made solution at the same concentration and temperature; if the fresh one is quiet and only the used one foams high, suspect something carried in. Adding a little of that cutting fluid to fresh solution and shaking again makes it clearer still.

If cutting fluid is the cause, cut how much reaches the washer first. Tilt parts after machining so fluid drains off or blow them off with air, and change the loading orientation of recessed parts. Skim off incoming oil, and change the solution according to foam and contamination rather than by date. If a change of cutting fluid is planned, review it together with the washing process, and use the bottle test first to see how the new fluid behaves in the cleaning solution.

Hypothesis 4: over-concentration

This hypothesis fits washers where concentrate is poured in whenever cleaning seems weak, or where the level lost to evaporation is made up with solution instead of water. A failed metering pump that keeps feeding concentrate is another case. Picture an operator who hears from the previous shift that cleaning is falling short and pours in plenty of concentrate. When the next shift starts the pump, foam rises much faster than usual, and cleaning is no better for it.

Foam is held up by surfactant at the film surfaces, so the more surfactant dissolved in the liquid, the faster new surfaces are covered and the better the films hold. The effect continues up to a certain concentration range (Pugh, 1996). Running the cleaner strong increases the foam-supporting ingredients just as much. A heated tank loses water as vapour in use, and evaporation takes only water while the chemicals stay behind (European Commission, 2006). If that gap is filled with solution or concentrate, the concentration creeps up with every top-up. Cleaning power does not rise in step with concentration, so a strong solution mainly grows foam and carries more chemical into the rinse.

Measure the solution concentration by the TDS method. If the alkalinity titration or refractometer reading sits above range, over-concentration is a likely suspect, and tracing the top-up log backwards shows when it started rising. If there is a metering pump, measure its actual output against the setting, and ask operators whether water make-up is automatic or manual and what they fill with.

If concentration is high, add water to bring it back into range, and set the rule that level lost to evaporation is made up with water only. Add cleaner only to cover a measured shortfall, and log the amount and time. Revise the work standard so that complaints of poor cleaning trigger a concentration check before any concentrate goes in, and check the metering pump's output at regular intervals.

Hypothesis 5: air drawn in

When cleaner, temperature and concentration all check out but foam still forms, look for the way air gets in. That happens when the level drops, as near the end of a shift, when a clogged filter starves the pump, when a suction pipe joint works loose, or when returning liquid pours onto the surface from a height. Over a day, a tank filled in the morning stays quiet, then starts to foam in the afternoon once parts have carried solution out and the level has fallen. The pump sounds rough, and the spray from the nozzles stops and starts.

Flow into a pump should be even and free of swirl and air. If too little liquid covers the suction inlet, a vortex with an air core can form at the surface and be drawn into the pump, so suction inlets have a minimum submergence to keep (HI, 2018). Air that enters the pump is sprayed out with the liquid and returns to the tank. Air is also dragged into the liquid wherever returning liquid falls fast onto the surface, and the amount depends on conditions such as the speed and height of the falling liquid (Biń, 1993). Bubbles that get in this way are wrapped in the solution's surfactant and become raw material for foam. Even with a low-foam cleaner, too much incoming air can make foam form faster than it breaks.

Start with the level when foam appears. Record the level gauge reading in the foam log, and if the tank can be seen into, check for a vortex turning on the surface above the suction inlet. Inspect suction pipework, joints and the pump shaft seal for places where air could leak in, and see whether the pressure difference across the filter has grown. Look also for return lines or overflow weirs pouring liquid from high above the surface. If foam drops when the level is brought back up or the filter is changed, the air path has been found.

Once the air path is found, close it. Fit automatic top-up or a low-level alarm so the level never falls below the minimum submergence, and place a plate that breaks vortices at the suction inlet. Repair loose joints and worn seals, and change filters by pressure difference. Discharge returning liquid below the surface or reduce its drop, and re-aim nozzles so they do not strike the tank surface directly.

Finding the cause

Even with all five hypotheses in doubt, ruling out the easiest first narrows things quickly. Bath temperature and level read straight off the instruments, and concentration takes one titration. Whether the cleaner is meant for spray use shows on a single TDS. Cutting fluid contamination needs a bottle test and a records check, so it comes next, and air leaks come last because the machine must be stopped to inspect them.

When the foam appears is the biggest clue. If it overflows only right after the morning start and settles as the solution warms, look at temperature and the cloud point; if it starts in the afternoon as the level falls, look at air drawn in. Foam that worsens just after concentrate goes in points to concentration, and foam that worsens after certain parts arrive or as the solution ages points to cutting fluid. Overflow from the first day of a new cleaner, whatever the temperature, means the cleaner itself is unsuited.

The bottle test splits the paths. Shake used solution and fresh solution at the same concentration side by side at wash temperature: if both foam high, the cleaner or temperature is at fault; if only the used one does, something carried in is. If both are quiet in the bottle but the washer still foams, the machine is putting air in, not the liquid.

If that still does not settle it, run control trials that change one thing at a time. Start the pump only after warm-up, fill the level to normal, change to fresh solution, and each time record foam height through the window at a set time after the pump starts, in the same way. Keep defoamer out of these trials. It hides the cause by holding the foam down, and its effect fades in use, which unsettles the comparison (Denkov, 2004). While hunting the cause, change conditions rather than add chemicals, and if foam must be knocked down at once, there are mechanical methods besides chemicals (Garrett, 2015). The job is done only when the washer runs for several days without overflowing.

The hypotheses can overlap. Cutting fluid emulsifiers building up in a bath that is also cold let foam pile up all the more easily, and strong solution in a low-level washer turns drawn-in air straight into foam. In such cases, bring the conditions that can be set at once, temperature, level and concentration, into range first, then revisit contamination and the cleaner with the bottle test under those conditions, because while the basics are unsettled, the effect of changing anything else cannot be compared fairly.

Limits and cautions

Cloud point, recommended temperature and concentration range differ by cleaner, so numeric decisions follow the cleaner's TDS and the supplier's guidance, and suction submergence and pipework changes are settled with the washer supplier. Depending on type, a defoamer can affect rinsing or later painting and plating, so check with the cleaner supplier and the downstream process owner before using one. The bottle test is a quick check for narrowing the cause; a formal choice of cleaner should rest on the supplier's test data together with trial runs on the actual washer.

Safety matters too. Overflowing foam makes floors slippery, so clear it at once, and keep foam from alkaline cleaners off skin and eyes with the protective equipment set out in the product's safety data sheet, the SDS. Heated baths give off water vapour and alkaline fumes and may need extraction (European Commission, 2006). Before looking into the tank or working on the suction inlet or filter, stop and lock out the pump and make sure the solution has cooled.

Sources

  1. Biń, A. K. (1993). Gas entrainment by plunging liquid jets. Chemical Engineering Science, 48(21), 3585–3630. https://doi.org/10.1016/0009-2509(93)81019-R
  2. Bonfillon-Colin, A., & Langevin, D. (1997). Why do ethoxylated nonionic surfactants not foam at high temperature? Langmuir, 13(4), 599–601. https://doi.org/10.1021/la950439i
  3. Brinksmeier, E., Meyer, D., Huesmann-Cordes, A. G., & Herrmann, C. (2015). Metalworking fluids—Mechanisms and performance. CIRP Annals, 64(2), 605–628. https://doi.org/10.1016/j.cirp.2015.05.003
  4. Denkov, N. D. (2004). Mechanisms of foam destruction by oil-based antifoams. Langmuir, 20(22), 9463–9505. https://doi.org/10.1021/la049676o
  5. European Commission. (2006). Reference document on best available techniques for the surface treatment of metals and plastics. European IPPC Bureau. https://eippcb.jrc.ec.europa.eu/reference/surface-treatment-metals-and-plastics
  6. Garrett, P. R. (2015). Defoaming: Antifoams and mechanical methods. Current Opinion in Colloid & Interface Science, 20(2), 81–91. https://doi.org/10.1016/j.cocis.2015.03.007
  7. Hydraulic Institute [HI]. (2018). ANSI/HI 9.8-2018, Rotodynamic pumps for pump intake design. https://law.resource.org/pub/us/cfr/ibr/inc/ansi/ansi.hi.9.8.2018.pdf
  8. International Organization for Standardization [ISO]. (1975). ISO 696:1975, Surface active agents — Measurement of foaming power — Modified Ross-Miles method. https://www.iso.org/standard/4896.html
  9. International Organization for Standardization [ISO]. (1991). ISO 1065:1991, Non-ionic surface-active agents obtained from ethylene oxide and mixed non-ionic surface-active agents — Determination of cloud point. https://www.iso.org/standard/5558.html
  10. Koczo, K., Lobo, L. A., & Wasan, D. T. (1992). Effect of oil on foam stability: Aqueous foams stabilized by emulsions. Journal of Colloid and Interface Science, 150(2), 492–506. https://doi.org/10.1016/0021-9797(92)90218-B
  11. Pugh, R. J. (1996). Foaming, foam films, antifoaming and defoaming. Advances in Colloid and Interface Science, 64, 67–142. https://doi.org/10.1016/0001-8686(95)00280-4

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis