Why did sludge volume jump after changing coagulant?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Water & Waste Treatment

Blaming the new product is the usual response when sludge rises after a coagulant change, but sludge is the solids removed from the wastewater plus the solids the chemicals themselves form, plus the water held with them, so simply switching products again tends to leave the cause in place. What actually drives it can be more metal hydroxide, overdosing, pH chemicals such as lime, higher alkalinity use, or a polymer pairing that no longer fits, and sometimes two or more at once.

Background

A few weeks after the coagulant was changed for price or supply reasons, the sludge withdrawal pump runs longer and the dewatering unit has to run more often. Effluent quality is unchanged, but the weight of sludge sent out each month and the cost of disposing of it have risen noticeably. A rise in sludge cost can outweigh the saving on chemicals. When sludge builds up quickly in the clarifier, the risk also grows that sludge not withdrawn in time spills over into the treated water.

Coagulation sludge mainly contains the solids removed from the wastewater and the metal hydroxides the coagulant forms. So the amount produced depends on plant flow, the dose of coagulant and other chemicals, and the suspended solids in the wastewater, and its character varies with the type and dose of coagulant. Drinking water plant data show that sludge from aluminium and iron coagulants compacts poorly, at only about 0.5 to 2% solids, and is correspondingly hard to dewater (EPA, 2011).

Here it matters to separate volume from weight. Sludge volume is the weight of dry solids in it divided by its solids concentration, so volume rises in one of two ways: the solids made by chemicals increase and the dry weight itself grows, or the solids stay the same but the sludge holds more water and becomes thinner. A drop in solids concentration from 2% to 1% alone doubles the volume taken up by the same weight of sludge.

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: work out the dry solids weight from daily sludge volume and solids concentration before and after the change, and set plant flow and the doses of coagulant, alkali and polymer for the same periods beside the active content stated in the two products' technical data sheets, the TDS.

Hypothesis 1: more metal hydroxide

Check whether dry solids have risen when the plant moved from a high-basicity polyaluminium chloride to aluminium sulphate or an iron salt, or when it switched to a product with a different active content and matched the dose by litres alone. The amount of metal needed for the same job differs by product, and nearly all the metal added turns into hydroxide and leaves as sludge. Think of a plant that, after a change of supplier, still doses the new coagulant at the same litres as before. Sludge brought up from the clarifier floor stretches more like jelly than before, and the truck that takes away dewatered cake comes more often.

When an aluminium or iron coagulant goes into water, the metal ions react with the water in hydrolysis, producing positively charged species and an insoluble amorphous hydroxide precipitate. The higher the dose, the more this precipitate sweeps particles up and enmeshes them, and which mechanism dominates depends on pH and dose (Duan & Gregory, 2003). The sludge from chemical precipitation is estimated by working out from the reaction equations how much precipitate the added chemicals form and adding the solids removed from the wastewater (Tchobanoglous et al., 2014). So a product that needs more metal for the same treatment result produces more dry solids. Hydroxide precipitation is known to produce large volumes of low-density sludge that burden dewatering and disposal (Fu & Wang, 2011), so even a small rise in dry weight can bring a larger rise in volume.

Find the aluminium or iron content of both products in their TDS, multiply by the daily dose, and compare the metal added per day before and after the change. If the litres are the same but more metal went in, this hypothesis is likely. Check also whether dry solids weight moved in step with the rise in metal dose. If the aluminium or iron content of the sludge can be measured, comparing it with sludge from before the change shows directly whether the metal hydroxide share has grown.

Once a higher metal dose is confirmed, reset the dose on a metal basis rather than by litres. Run jar tests with the new product to find the lowest metal dose that meets the treatment target, and set the chemical pumps to that. If a product achieves the same result with less metal, compare products on total cost including sludge disposal, not on chemical price alone.

Hypothesis 2: overdosing

Overdosing tends to grow out of operating habits meant to protect the effluent: setting the dose generously after the change to make sure the effluent is clear, leaving the dose fixed at commissioning unchanged after the wastewater has changed, or adding a little more coagulant each time the effluent looks cloudy. Picture a plant that, on bringing in a new coagulant, turned the pump stroke well up to avoid any risk of breaching the effluent limit. Large floc forms quickly in the reaction tank and the effluent is clear, but pH after coagulation reads lower than before and the sludge holding tank fills faster by the day.

Coagulant is not a chemical where more is better. Competing reactions and conditions such as alkalinity make it hard to calculate the right dose, so frequent jar tests are needed to confirm it, and overdosing can reduce treatment effectiveness (EPA, 2000). Overdosing, like underdosing, can lower solids removal efficiency, and raising the dose of metal salt can depress pH further and increase the metal dissolved in the water (EPA Ireland, 2002). Coagulant beyond what treatment needs adds little to removal; it turns into hydroxide itself and piles up as sludge. That is why clear effluent alone does not show whether the dose is right.

Jar tests give the surest check. Divide real wastewater into several jars, dose coagulant in steps below and above the current dose with the current dose in the middle, and under the plant's mixing and settling conditions look at supernatant turbidity, the treatment target parameters and the volume of settled sludge together (ASTM International, 2019). If jars dosed below the current level still meet the target, the difference is overdose. On the floor, measure pH after coagulation and the actual output of the chemical pumps to confirm that the amount going in matches the setting.

Bring the dose down to the lowest level that met the target in the jar tests, and watch effluent quality and sludge quantity together for several days. Repeat jar tests whenever the wastewater changes, and instead of raising the dose each time the effluent clouds briefly, look for the cause first. If the dose is controlled automatically from influent quality, confirm that the control settings have been reset for the new product.

Hypothesis 3: lime and pH chemicals

At plants that set pH with hydrated lime or quicklime, lime use after the coagulant change is an important clue. This matters most when the new coagulant pulls pH down further so more lime is needed, when both the neutralisation of acidic wastewater and the coagulation step rely on lime, and when uneven lime quality leaves many undissolved grains. At a plant using lime slurry, there comes a month when the lime storage tank has to be refilled noticeably more often. The sludge is paler than before, and rubbing it between the fingers reveals white grains.

Lime does not simply change pH and disappear. In water it forms calcium carbonate, which acts as a coagulant in its own right, but used alone it must be added in large quantities and it generates more sludge than other coagulants. Adding treatment chemicals, especially lime, can increase the volume of waste sludge by up to 50% (EPA, 2000). Treatment design likewise raises the suspended solids entering the clarifier to account for the lime solids added and the precipitates formed, and assumes a little more lime than the amount that reacts with acidity and metals (EPA, 1983). Calcium carbonate sludge from lime softening at drinking water plants compacts better and dewaters more easily than coagulation sludge, but when magnesium hydroxide forms with it, it becomes harder to handle (EPA, 2011). If more lime went in after the coagulant change, much of the difference can add to dry solids.

Compare daily lime use from purchase or dosing records before and after the change. Measuring calcium in the dried sludge gives a sense of the calcium carbonate share, and seeing whether it fizzes when dilute acid is dropped on it shows at once whether calcium carbonate is present. Check the lime slurry concentration and the purity of the lime as well, to see whether some lime goes straight into the sludge undissolved.

If lime is swelling the sludge, choose the pH chemical again. Caustic soda and sodium carbonate dissolve without leaving solids, so they are worth comparing on chemical price plus sludge disposal cost. If lime stays, manage slurry concentration and mixing to cut undissolved grains, and look at the same time for a coagulant product or dosing conditions that pull pH down less.

Hypothesis 4: higher alkalinity use

Where the water being treated has low alkalinity, its capacity to take up and neutralise acid, pH in the coagulation tank can drop after a coagulant change. It shows up readily after a move from a high-basicity product to a low-basicity one, at plants using industrial water close to soft water, and in wet spells when rain dilutes the influent. From the day after the coagulant change, the coagulation tank pH logs a little lower and the alkali dosing pump starts running more often. The floc in the coagulation tank is small and light and settles slowly.

When a metal salt such as aluminium sulphate hydrolyses, it forms acid, sulphuric acid in this case, along with the hydroxide, and the water's alkalinity neutralises that acid. If the water lacks alkalinity, it has to be made up with lime or sodium carbonate, and acid left in the water pushes pH out of the range suited to coagulation (EPA Ireland, 2002). Polyaluminium chloride has high basicity, so it releases less acid on hydrolysis than aluminium sulphate and needs less alkali adjustment, generally works at lower doses and is effective over a wider pH range (NHMRC, n.d.). So switching from a high-basicity product to a low-basicity one means more alkali for the same metal, and if that alkali is lime it adds to the sludge. If alkalinity is not made up and pH stays low, the floc can become small and light and settle holding a lot of water, and if operators try to make up for it with more coagulant, hydroxide grows again.

Measure alkalinity and pH in the influent and after coagulation before and after the change to see how much more alkalinity the coagulant uses. Compare basicity in the two products' TDS, and set daily use of the alkali make-up chemical for the same periods side by side. In jar tests, keeping the coagulant the same and varying only the alkali make-up shows whether floc grows and settled sludge volume shrinks once pH is put right.

Here the first thing to settle is how alkalinity is made up. Make it up with sodium carbonate or caustic soda, which leave no solids, and fix the pH suited to coagulation by jar test and hold it there. If a high-basicity product works out better once sludge and chemical costs are added together, revisit the coagulant choice, and at plants where influent alkalinity changes with the season, reset the make-up amount each time it does.

Hypothesis 5: polymer mismatch

A coagulant change also calls for a fresh look at whether the polymer used with it still pairs well. This applies when the coagulant was changed but the polymer was left as it was, when, the other way round, the polymer was cut back or dropped to get by on inorganic coagulant alone, or when the polymer's dosing point or dilution has changed. Say a plant switched to a new inorganic coagulant but left the anionic polymer it had used for years untouched. The floc swells like cotton wool and settles slowly, and a thicker sludge layer than before builds up on the clarifier floor.

A polymer is a long, charged chain molecule that links the small floc made by a metal coagulant into larger, tougher floc. Polymers are used to improve the settling of floc produced by aluminium or iron coagulants, adding density and toughness to it. In special cases a polymer is used as the primary coagulant to replace inorganic coagulant wholly or partly, and the mass of sludge for disposal then falls (EPA Ireland, 2002). Which water and particles a polymer suits depends on the type and strength of its charge and on its molecular size (Bolto & Gregory, 2007), so when a coagulant change alters the surface charge of the floc, the old polymer may no longer fit well. With an ill-fitting polymer, floc clumps loosely and holds a lot of water, and that sludge takes up more volume for the same dry weight. Polymers are also used as conditioners before sludge dewatering (EPA, 2000), so the polymer at the dewatering stage faces the same question.

In jar tests, hold the new coagulant at the same dose and vary only the polymer type and dose. Set the current polymer, a polymer of different charge and no polymer side by side, and compare floc size, settling speed and the volume of sludge settled on the bottom after a set time (ASTM International, 2019). On the floor, compare the solids concentration of clarifier sludge and dewatered cake with figures from before the change, and check the polymer solution's concentration and make-up date and the mixing at the dosing point.

If the polymer turns out to be the misfit, choose a polymer to pair with the new coagulant again by jar test with the supplier. Test at the same time whether a well-matched polymer allows some of the inorganic coagulant to be cut, looking for a way to lower sludge mass and volume together. Retune the type and dose of the dewatering polymer on the new sludge as well, and write the changed conditions into the operating procedure.

Finding the cause

The dry solids weight worked out in the background is the first fork. If dry weight rose after the change, the chemicals are making more solids, so look at how much chemical went in: metal dose, overdosing and lime. If dry weight is unchanged and only volume rose, the sludge is holding more water, so look at what governs floc quality: pH, alkalinity and polymer.

Next come the chemical records. If the litres are unchanged but metal dose has risen, look at hydroxide; if jar tests meet the target at a lower dose, look at overdosing. If lime use has risen too, lime is adding to the sludge directly, and if the reason is a drop in pH after coagulation, higher alkalinity use lies behind it. If pH and alkalinity after coagulation are the same as before and only the polymer is unchanged, suspect the polymer first.

When the records alone do not decide it, control jar tests will. Set out jars with the old and new coagulants at the same metal dose, jars that vary only the alkali make-up, and jars that vary only the polymer, and compare settled sludge volume after a set time and supernatant quality. Change only one thing at a time, or there is no telling what reduced the sludge.

The five can feed one another. Switching to a low-basicity product uses more alkalinity, making up the shortfall with lime adds lime solids, and making up for poorer floc with more coagulant increases overdose and hydroxide together. In such cases first reset the coagulant dose on a metal basis, next settle the alkali make-up chemical and pH, and finally choose the polymer again. Done the other way round, pH shifts after the polymer has been matched, and it has to be matched again.

After the fix, record dry sludge weight per cubic metre treated and sludge solids concentration for several weeks, by the same method as before the change. Close the matter once both are back at their earlier levels while effluent quality still meets the limit.

Limits and cautions

Suitable types and doses of coagulant, alkali and polymer differ with wastewater character, treatment targets and equipment, so set the figures from each product's TDS and jar tests on real wastewater. Changing coagulant can affect residual metal in the effluent, discharge limits and sludge disposal criteria, so check the applicable regulations and permit conditions, and tell the disposal contractor and the regulator before changing how sludge is disposed of. If the problem is a shortage of dewatering or clarifier capacity, review it with a water treatment design specialist.

Bring chemical handling rules into line with the new products as well. Iron coagulant solutions are aggressive, corrosive acidic liquids, lime must be handled so that dust does not rise, and polymer powder dropped on a wet floor turns into a tough, slippery jelly that is easy to fall on (EPA Ireland, 2002). Acidic coagulants, lime and caustic soda can react with heat when mixed, so store them apart and wear protective equipment according to each product's safety data sheet, the SDS. Entering sludge holding tanks and clarifiers follows confined space procedures.

Sources

  1. ASTM International. (2019). ASTM D2035-19, Standard practice for coagulation-flocculation jar test of water. https://store.astm.org/d2035-19.html
  2. Bolto, B., & Gregory, J. (2007). Organic polyelectrolytes in water treatment. Water Research, 41(11), 2301–2324. https://doi.org/10.1016/j.watres.2007.03.012
  3. Duan, J., & Gregory, J. (2003). Coagulation by hydrolysing metal salts. Advances in Colloid and Interface Science, 100–102, 475–502. https://doi.org/10.1016/S0001-8686(02)00067-2
  4. Environmental Protection Agency Ireland [EPA]. (2002). Water treatment manuals: Coagulation, flocculation & clarification. https://www.epa.ie/publications/compliance--enforcement/drinking-water/advice--guidance/water-treatment-manuals---coagulation-flocculation--clarification.php
  5. Fu, F., & Wang, Q. (2011). Removal of heavy metal ions from wastewaters: A review. Journal of Environmental Management, 92(3), 407–418. https://doi.org/10.1016/j.jenvman.2010.11.011
  6. National Health and Medical Research Council [NHMRC]. (n.d.). Polyaluminium chloride. Australian drinking water guidelines, Part 5: Treatment chemicals. Retrieved November 2026. https://guidelines.nhmrc.gov.au/australian-drinking-water-guidelines/part-5/treatment-chemicals/polyaluminium-chloride
  7. Tchobanoglous, G., Stensel, H. D., Tsuchihashi, R., & Burton, F. (2014). Wastewater engineering: Treatment and resource recovery (5th ed.). McGraw-Hill Education.
  8. U.S. Environmental Protection Agency [EPA]. (1983). Development document for effluent limitations guidelines and new source performance standards for the metal finishing point source category. Office of Water Regulations and Standards. https://www.epa.gov/sites/default/files/2015-10/documents/metal-finishing_dd_1983.pdf
  9. U.S. Environmental Protection Agency [EPA]. (2000). Wastewater technology fact sheet: Chemical precipitation (EPA 832-F-00-018). Office of Water.
  10. U.S. Environmental Protection Agency [EPA]. (2011). Drinking water treatment plant residuals management technical report: Summary of residuals generation, treatment, and disposal at large community water systems (EPA 820-R-11-003).

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.