Raising or changing the coagulant dose is the usual response when COD will not come down, but coagulation mainly captures particles and colloids, so it does little against organics dissolved in the water. What actually keeps COD high can be dissolved organics such as surfactants and glycols, a fraction that coagulation cannot remove, inhibited biological treatment, swinging loads or chloride interfering with the measurement, and sometimes two or more at once.
Background
Even after changing the coagulant and raising its dose, effluent COD will not come down from near the limit. The treated water is clear and odourless, yet the figure on the analysis sheet has not moved for weeks. Exceeding the limit brings regulatory action and the cost of putting it right, and while an ineffective chemical keeps going in, chemical and sludge disposal costs build up. Water rich in organics consumes oxygen as it breaks down once it reaches a river, which puts fish and other aquatic life under strain.
COD, chemical oxygen demand, expresses the organic matter in water as the amount of oxygen needed to burn it with a strong oxidant. Wastewater COD can be split into a particulate part and a dissolved part, and each again into what microbes can break down and what they cannot. Each process takes a different share. Coagulation and settling mainly remove particles and colloids, biological treatment removes dissolved organics that microbes can break down, and the share that is both dissolved and hard to break down passes through both and stays in the effluent (Tchobanoglous et al., 2014).
So COD holds out for three broad reasons: the nature or amount of incoming organics does not match the treatment process, the process itself is underperforming, or the figure is measured higher than the organics actually present. If dissolved organics are behind either of the first two, changing coagulants barely moves the figure, and in the last case there may be nothing in the plant to fix at all.
In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: sample each treatment stage, measure COD on filtered and unfiltered portions side by side, measure chloride and BOD on the same samples, and compare the results with flow, chemical doses and production schedule on the high-COD days and with the treatment chemicals' technical data sheets, the TDS.
Hypothesis 1: dissolved organics
In plants with degreasing and washing, water-based cutting fluids or coolants, or antifreeze and heat transfer fluids, dissolved organics can make up a large share of COD. Typical times are when a wash or degreasing tank is emptied, when long-used water-based cutting fluid or glycol coolant is changed, and after a switch of cleaner, all moments when concentrated liquid enters the wastewater at once. Think of a plant that emptied and refilled a degreasing tank used for several weeks on a Friday afternoon. On Monday morning after the weekend, the holding tank water foams, the treated water is still clear, yet that week's COD results are unusually high.
The trouble is that these substances are dissolved, so they are not captured as solids. Surfactants, the main ingredient of cleaners, keep substances that do not mix with water, such as oil, dispersed in it. So in wastewater carrying soaps and detergents, even oil tends to stay in the water (EPA, 2000). Most surfactants are broken down by microbes where oxygen is present, but some persist where it is absent, and nonionic and cationic surfactants bind strongly to sludge and sediment (Ying, 2006). Glycols exert a large oxygen demand. In tests on aircraft deicers, products based on propylene glycol showed a larger five-day BOD than those based on ethylene glycol, and the ethylene glycol products broke down more slowly (Corsi et al., 2012). Coagulation barely removes such substances in concentrated liquid, and they pass on to biological treatment, so in plants with little or no biological treatment most of them remain as effluent COD.
Start by finding where it comes from. Sample each process discharge point and measure COD, and match the schedules for wash tank changes, cutting fluid changes and coolant drains against the high-COD days. Note foam, oily smell and colour changes in the holding tank as well. If COD of filtered and unfiltered samples is nearly the same, the organics are dissolved, and checking the safety data sheets, the SDS, of cleaners and cutting fluids for surfactants and glycols narrows down the suspects.
If concentrated waste liquid is the cause, the first step is to keep it out of the general wastewater. Collect concentrated liquids such as degreasing baths, cutting fluids and coolants separately, and bleed them in slowly to suit the plant's capacity, send them off-site, or give them their own pretreatment. On wash lines, cut the incoming amount itself by adding rinse stages or reducing the liquid carried out on parts. When changing cleaner, check biodegradability and the effect on the treatment plant with the supplier along with cleaning performance.
Hypothesis 2: non-coagulable COD
This hypothesis comes to the front at plants set up to lower COD by physicochemical treatment alone, such as coagulation and settling, or where a certain COD always remains even after biological treatment. It shows up when a process rich in organics is added to a plant built to remove heavy metals or suspended solids, and when COD is chased by switching coagulants one after another. Water leaving the clarifier is clear with low turbidity, yet whatever coagulant is used, COD stays at much the same value.
What coagulation captures is particles. Coagulants and polymers reduce the charge on small, negatively charged particles and bridge them so they clump and settle, and what chemical precipitation removes is metals, suspended solids, oil and some organic substances (EPA, 2000). Dissolved organics of molecular size are not particles to be clumped this way, so most stay in the water, and the dissolved share that microbes find hard to break down passes biological treatment as well and remains in the effluent (Tchobanoglous et al., 2014). Biological treatment adds a share of its own. The organics that microbes release into the water as they grow on their food or die and break down are called soluble microbial products; they made up most of the dissolved organics in biological treatment effluent, and their amount varied with operating conditions such as retention time, organic loading, sludge age and temperature (Barker & Stuckey, 1999).
Split samples from before and after coagulation into filtered and unfiltered portions and measure COD. If filtered COD after coagulation is almost the same as filtered COD before it, coagulation is not touching the dissolved share. Jar tests that vary coagulant type and dose without moving filtered COD confirm it. Then the ratio of BOD to COD in the same sample gives a sense of whether the remaining share can be broken down by microbes or is hard to break down.
Rather than switching coagulants again, choose a process that handles the dissolved share. If the share microbes can break down is large, add or enlarge biological treatment; if the hard-to-break-down share is large, consider processes such as activated carbon adsorption or advanced oxidation. Placing advanced oxidation ahead of biological treatment turns persistent substances into intermediates that break down more easily, so the biological stage after it can be used at lower cost (Oller et al., 2011). If the share left in biological effluent is the problem, adjust operating conditions such as sludge age and loading as well.
Hypothesis 3: inhibited biology
When a plant with biological treatment sees COD jump and the biological reactor itself starts to look different, check whether the microbes have stopped working. Typical cases are a new process using new chemicals or biocides, metals coming through after a problem in metal treatment, and a sudden inflow of strong acid, alkali or hot water. Picture the week a new chemical came into use in paint booth scrubber water. The colour of the foam on the aeration tank changes, sludge in the secondary clarifier no longer settles as usual, and the treated water gradually turns cloudy.
Biological treatment works by microbes eating dissolved organics and burning them with oxygen, so when their respiration is blocked the organics pass straight through. Inhibition is when pollutants in wastewater or sludge cause operational problems for biological treatment and impair its ability to remove pollutants such as BOD and suspended solids, and excessively hot wastewater can also inhibit biological activity. The concentration at which inhibition sets in depends on the process and its conditions, so literature values must be used with caution, and developing site-specific inhibition levels is encouraged (EPA, 2004). Several bioassays, respirometry among them, have been studied for assessing toxicity to activated sludge (Ren, 2004). Inhibited microbes not only eat less organic matter but also form clumps poorly, so they can send drifting fragments of biomass into the effluent along with dissolved COD.
Checking starts with measuring how well the microbes breathe. Take aeration tank sludge, measure how fast it uses oxygen, and compare with past records or sludge from a healthy plant. Mixing the suspect wastewater into sludge at several dilutions and measuring oxygen use shows from which concentration respiration falls, and this approach is standardised as the activated sludge respiration inhibition test. The same test can use a nitrification inhibitor to separate the effect on organic breakdown from the effect on nitrification (OECD, 2010). On the floor, also look at aeration tank pH, temperature, dissolved oxygen and sludge settleability, and check metals in the influent and the SDS of any new chemical coming in.
Once an inhibitor is identified, stop that flow ahead of biological treatment or treat it separately. Separate waste liquids containing biocides or toxic chemicals for off-site disposal or pretreatment, and if metal treatment has been unsettled, put that right first. Neutralise strong acid and alkali and cool hot water in a holding tank before sending them on. While the microbes recover, reduce the incoming load, and if needed bring in sludge from a healthy plant to rebuild the population.
Hypothesis 4: load swings
At some plants COD is not always high but spikes only on certain days or at certain hours. This fits plants that concentrate production on certain weekdays, sites that release batch process waste liquids all at once at set times, and sites whose holding tank is small or missing, so water is treated as it arrives. A week with production crammed into the end of the month looks like this. By day, wash water and waste liquids pour in and the holding tank level climbs fast; by night almost nothing comes and the plant runs as if empty.
Treatment processes are designed for set ranges of flow and concentration, so at moments well beyond those ranges they cannot keep up. In biological treatment, the amount of microbes does not grow quickly, so a sudden rush of organics is passed on before it is fully broken down, and in coagulation the chemical doses no longer fit the changed concentration. That is why an equalisation tank that evens out swings in flow and concentration improves the performance of the biological and chemical treatment that follows (Tchobanoglous et al., 2014). Discharges released at a flow or concentration high enough to disrupt treatment are prohibited under the US pretreatment rules for wastewater sent to public sewage works (EPA, 2004). The amount of soluble microbial products left in biological effluent also varied with organic loading (Barker & Stuckey, 1999).
Measuring influent COD and flow hour by hour over a day or more shows the shape of the swings. A single daily grab sample shows only that moment, so use an automatic sampler at fixed intervals or composite samples collected in proportion to flow. Overlay the times effluent COD was high on the times influent load peaked to see whether the first follows the second by the plant's retention time, and match batch discharge and production schedules as well.
For load swings, evening out what comes in has the biggest effect. Install or enlarge an equalisation tank to hold surges and send them on at a steady flow, mixing its contents to even out concentration too. Spread batch discharges over time or collect them in the equalisation tank to bleed in gradually. Agreeing discharge schedules with the treatment plant operator when planning production also helps.
Hypothesis 5: chloride interference
When COD is inexplicably high at a plant with hydrochloric acid pickling, or where ion exchange regeneration waste or brine mixes in, suspect the figure first. Signs are a high COD in a sample taken when there should be almost no organics, or very different results when the same sample goes to another laboratory. At a plant receiving pickling rinse and regeneration waste together, a sample taken on a day when the washing and painting lines were idle and only pickling ran shows much the same COD as usual.
COD analysis burns the sample with dichromate, a strong oxidant, and chloride is also oxidised by it, making COD read higher than the organics present. That is why mercuric sulphate is added in the analysis to bind chloride (EPA, 1993). This masking has limits. The standard small-scale sealed-tube method applies to samples with chloride at or below 1,000 mg/L, and samples with more chloride are to be diluted below that first (ISO, 2002). In one study, samples with high salinity and little organic matter measured by the standard method were off by 50 to 85%, while a method with adjusted mercuric sulphate ratio and oxidant concentration brought the error below 10% (Vyrides & Stuckey, 2009). The more chloride in the wastewater, and the less organic matter, the larger chloride's share of the measured value.
Measure chloride in the same sample first and see whether it is within the scope of the analytical method in use. If it is beyond it, analyse again at a different dilution, and if the dilution-corrected values differ widely, suspect chloride interference. To see the organic content another way, measure total organic carbon, TOC, on the same sample and compare whether its relation to COD matches the usual. Tell the laboratory the sample's chloride concentration and confirm which masking method was used.
Here the analysis needs putting right before the plant. Agree dilution and masking conditions suited to high-chloride samples with the laboratory, and check what the official test method used for the discharge limit allows. Managing how much of a high-chloride stream mixes with other wastewater can also keep samples within the measurement range. If the value is tied to a compliance decision, document the basis of the measurement and discuss it with the regulator.
Finding the cause
There is no need to investigate all five at once. Checking that the figure is right comes first, as it is cheapest and quickest. Measuring chloride in the sample and seeing whether it is within the method's scope is simple, and if that is the problem, there may be no need to touch the plant at all.
If the figure is right, set filtered and unfiltered COD side by side at each treatment stage. If filtered COD is unchanged across coagulation, the dissolved share is the problem, and the path divides on whether that share stays at a steady level or rises only on certain days. A steady level points to a fraction coagulation cannot remove or that is hard to break down; a rise on certain days points to dissolved organics coming in, as with a wash tank change, or to load swings. The ratio of BOD to COD also helps at this fork.
In a plant with biological treatment, the state of the biological reactor is the next clue. If sludge settles poorly, foam or colour has changed and oxygen use is slower than usual, the case leans towards inhibited microbes; if the microbes are healthy but effluent COD rises and falls with influent load, look at load swings. Overlaying influent load and effluent COD from time-series samples separates the two.
If more than one is still standing, move on to control trials that remove one factor at a time. Run for a few days with the suspect waste liquid kept out, or run jar tests and respiration inhibition tests side by side on the same wastewater, changing one thing at a time to see what made the difference. Afterwards, measure COD again with the same sampling and the same method and compare with before; only a result that holds over several days counts as a fix.
Some days bring several causes at once. On the day a wash tank is emptied, an inflow of dissolved organics and a load swing arrive together, and surfactants or biocidal ingredients in that liquid may also inhibit the microbes. In such cases separate concentrated waste liquids and even out the flow first, then look again at biological treatment and coagulation. Only once the incoming water is steady does the effect of changing a treatment process show in the figures.
Limits and cautions
Organic parameters, values and official test methods in discharge limits differ by country, region, industry and permit conditions, so decisions follow the applicable regulations, the permit and results from an accredited laboratory. Set coagulant and polymer doses from the treatment chemicals' TDS and jar tests on real wastewater. Equipment changes such as expanding biological treatment, activated carbon or advanced oxidation should be decided with a water treatment design specialist on the basis of trials with the wastewater to be treated.
Look after safety in the laboratory and on the floor as well. Mercuric sulphate used in COD analysis is flagged as a potentially highly toxic or hazardous chemical, so analysis waste is handled separately as mercury waste (EPA, 1993). Handle concentrated cleaners, cutting fluids, glycols and biocides with protective equipment as each product's safety data sheet, the SDS, directs, and store oxidants for advanced oxidation apart from other chemicals. Entering holding or treatment tanks follows confined space procedures.
Sources
- Barker, D. J., & Stuckey, D. C. (1999). A review of soluble microbial products (SMP) in wastewater treatment systems. Water Research, 33(14), 3063–3082. https://doi.org/10.1016/S0043-1354(99)00022-6
- Corsi, S. R., Mericas, D., & Bowman, G. T. (2012). Oxygen demand of aircraft and airfield pavement deicers and alternative freezing point depressants. Water, Air, & Soil Pollution, 223(5), 2447–2461. https://doi.org/10.1007/s11270-011-1036-x
- International Organization for Standardization [ISO]. (2002). ISO 15705:2002 Water quality — Determination of the chemical oxygen demand index (ST-COD) — Small-scale sealed-tube method. https://www.iso.org/standard/28778.html
- Oller, I., Malato, S., & Sánchez-Pérez, J. A. (2011). Combination of Advanced Oxidation Processes and biological treatments for wastewater decontamination—A review. Science of the Total Environment, 409(20), 4141–4166. https://doi.org/10.1016/j.scitotenv.2010.08.061
- Organisation for Economic Co-operation and Development [OECD]. (2010). Test No. 209: Activated sludge, respiration inhibition test (carbon and ammonium oxidation). OECD Guidelines for the Testing of Chemicals, Section 2. OECD Publishing. https://doi.org/10.1787/9789264070080-en
- Ren, S. (2004). Assessing wastewater toxicity to activated sludge: Recent research and developments. Environment International, 30(8), 1151–1164. https://doi.org/10.1016/j.envint.2004.06.003
- Tchobanoglous, G., Stensel, H. D., Tsuchihashi, R., & Burton, F. (2014). Wastewater engineering: Treatment and resource recovery (5th ed.). McGraw-Hill Education.
- U.S. Environmental Protection Agency [EPA]. (1993). Method 410.4: Determination of chemical oxygen demand by semi-automated colorimetry (Revision 2.0). https://www.epa.gov/sites/default/files/2015-08/documents/method_410-4_1993.pdf
- U.S. Environmental Protection Agency [EPA]. (2000). Wastewater technology fact sheet: Chemical precipitation (EPA 832-F-00-018). Office of Water.
- U.S. Environmental Protection Agency [EPA]. (2004). Local limits development guidance (EPA 833-R-04-002A). Office of Wastewater Management. https://www.epa.gov/npdes/npdes-pretreatment-local-limits-additional-information
- Vyrides, I., & Stuckey, D. C. (2009). A modified method for the determination of chemical oxygen demand (COD) for samples with high salinity and low organics. Bioresource Technology, 100(2), 979–982. https://doi.org/10.1016/j.biortech.2008.06.038
- Ying, G.-G. (2006). Fate, behavior and effects of surfactants and their degradation products in the environment. Environment International, 32(3), 417–431. https://doi.org/10.1016/j.envint.2005.07.004