Why does gas engine oil lose its base number so quickly?
- Type
- Application notes
- Published
- 23 November 2026
- Prepared by
- Jonghwan Moon
- Product group
- Equipment/Service Lubricants
Switching to a higher base number oil is the usual response when base number falls fast, but unless the source of the acid eating it is found, the new oil goes the same way, and the extra ash can bring other trouble to valves and combustion chambers. What actually drives it can be sulphur and halogens in the fuel gas, faster oxidation and nitration, too little make-up oil, high oil temperature or an ash level that does not suit the fuel, and sometimes two or more at once.
Background
Every time an oil analysis report arrives, the base number figure has dropped well below the last one. The oil reaches the engine maker's change limit sooner each time, so oil that would once have had plenty of life left has to be drained early. On gas engines that run around the clock, such as combined heat and power or biogas plants, more frequent changes mean more oil cost, more waste oil disposal and more downtime for changes. Nor can the changes simply be put off, because acids may attack engine metal and deposits may build up.
Base number expresses the amount of basic material in an oil by titrating it with acid, and it is also used as an indicator of in-service degradation. There are two test methods for used oil base number; the one using a stronger acid also counts weak bases that do not protect the oil from acids, so the two methods' values are not interchangeable, and the standard says condemning limits must be set empirically (ASTM International, 2026). Metal additives such as calcium, which do the work of neutralising acid, do not burn, so they remain as ash once the oil has burnt (Sutton, 2022).
Base number falls either because acid has come in and used up that much base, or because less fresh oil is coming in to top it up. The acid may come from impurities in the fuel gas burning, or from the oil itself oxidising and nitrating. A study of stationary gas engine oils likewise found that oxidation set oil life in some engines, nitration in others and base number depletion in others (Girshick, 2023).
In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: lay out base number, acid number, oxidation, nitration, viscosity and wear metals from the last several oil analyses against running hours on one sheet, attach fuel gas analyses and make-up records from the same period, and compare them with the oil's technical data sheet, the TDS, and the engine maker's limits.
Hypothesis 1: acidic fuel gas
On engines burning landfill gas, sewage sludge digester gas or farm biogas instead of natural gas, this hypothesis comes to mind first. The trace components of biogas differ from site to site: a study comparing landfill, sewage works and farm biogas found sulphur compounds mainly in landfill and farm gas and organic silicon compounds in landfill and sewage gas (Rasi et al., 2007). A study of seven UK landfill sites judged total chlorine from organochlorine compounds at three of them to be at a level that could damage gas engines used for power generation (Allen et al., 1997). Look at this hypothesis especially when the adsorbent in the gas treatment unit is overdue for change or gas has started coming from a new landfill cell.
In the month the activated carbon in the gas treatment unit was changed late, the oil sample taken then shows base number dropping more steeply than usual and copper noticeably up. At that month's service, deposits in the combustion chamber and around the valves are thicker than usual.
Halogen-bearing hydrocarbons form corrosive products in combustion that can badly damage engines and pipework (Muñoz et al., 2015). Part of the acid gases from combustion is carried into the crankcase in blow-by gas past the piston rings, and base number falls by however much the detergent base in the oil neutralises. In a study that analysed the oil of an engine running on filtered biogas at set running-hour intervals, hydrogen sulphide affected oil performance and engine wear, and copper exceeded the recommended maximum (Bertinatto et al., 2017). In deposits from landfill gas engines, sulphur and silicon were found in every sample and sulphur was detected in the oil as well, and the same study notes that hydrogen sulphide can give off sulphur dioxide and corrode metal parts (Konkol et al., 2022).
Fuel gas analysis is the starting point. Measure hydrogen sulphide, total chlorine and fluorine, and siloxanes before and after the treatment unit, and do it periodically rather than once, because gas composition varies by site and over time. On the oil side, see whether the slope of base number loss coincides with periods of worse gas, whether acid number rises with it, and whether wear metals such as copper and iron have increased. Put the treatment unit's adsorbent change records on the same sheet.
If the fuel gas is the cause, the root fix is to cut the acid before it enters the engine. Reset change intervals for hydrogen sulphide removal and adsorbents such as activated carbon to suit the gas analysis, and hold the treated gas to the engine maker's fuel gas specification. For the acid that remains, choose an oil with more base reserve from those the engine maker allows for that fuel, and set change intervals from the oil analysis trend rather than fixed hours.
Hypothesis 2: oxidation, nitration
If base number falls fast even on a clean fuel such as natural gas, check whether the oil is making acid itself. Typical cases are after a change to the air/fuel ratio setting, during long running at or above rated load, after ignition timing adjustment, and when ring wear has increased blow-by. The combustion type matters too: in the stationary gas engine oil study cited earlier, nitration was a common reason for oil changes in engines running near stoichiometric air/fuel ratio and oxidation in lean-burn engines (Girshick, 2023).
Take oil sampled after an engine was kept near rated load through a summer demand peak. In the infrared analysis the nitration value has jumped above earlier samples, viscosity is up, and the oil filter's differential pressure is climbing faster than before.
When nitrogen oxides formed in combustion enter the crankcase with blow-by gas and react with the oil, a range of nitration products builds up, and these can raise the oil's viscosity, acidity and insolubles, leading to ring sticking and filter plugging (ASTM International, 2022). The rate of nitration is linked to operating conditions such as air/fuel ratio, engine load and oil temperature; it rises with load, and when poor ring sealing increases blow-by, more nitration products accumulate in the crankcase (Exxon Mobil Corporation, 2009). Oxidation is a separate branch of degradation in which oil reacts with oxygen, and oxidised oil has shown acid number and viscosity rising together (Iwase et al., 2024). Both branches build acid in the oil, so base number falls as it is neutralised.
There is a standard method for measuring oxidation and nitration by infrared spectroscopy against new oil, so measuring each sample the same way reveals the trend (ASTM International, 2023a). Where to look depends on whether oxidation or nitration is rising. If nitration rises, look at air/fuel ratio and exhaust oxygen, ignition timing, load records and blow-by; if oxidation rises, move on to oil temperature and the cooling system. Check at the same time that the crankcase ventilation system is not blocked.
The first fix for nitration is returning air/fuel ratio and ignition timing to the engine maker's settings, along with cutting excessive load running and restoring crankcase ventilation. If blow-by has increased, add rings and liners to the maintenance plan. If oxidation is the cause, see whether it is still fast after temperature is corrected, and consider an oil with better oxidation stability from the engine maker's approved list.
Hypothesis 3: little make-up oil
Gas engines are often built to use little oil, which also means little fresh oil goes in during operation. If oil consumption has dropped sharply after an overhaul, the automatic make-up unit has failed and topping up is done by hand, or the engine has been replaced by a model with less oil for the same output, look at make-up first.
The overhauled engine now uses far less oil than before, which pleases the operators. Yet in the samples taken since, with the same fuel and the same oil, base number reaches the change limit sooner than before the overhaul.
In an engine that consumes oil, fresh oil goes in to replace what is lost, diluting the used oil and adding new base and additives all the time. Make-up does not itself stop nitration, but since new oil mixes in and degraded oil leaves, the higher the make-up rate in a given engine, the slower the oil deteriorates (Exxon Mobil Corporation, 2009). Conversely, with little make-up the oil has to hold out on its own against the same acid, so base number reaches the limit sooner. Oil volume works the same way: a diesel engine study found the drain interval proportional to sump volume for the same stress on the oil (Prasad & Lakshminarayanan, 2012). So an engine that now uses less oil can, in effect, show base number falling faster.
The check is turning make-up into numbers. Log the oil added over set running hours to get make-up per unit output and per hour, and work out what fraction that is of the total oil volume in the sump and any external tank. On the same sheet, see how this figure changed before and after an overhaul or equipment fault, and whether the base number slope changed with it. If there is an automatic make-up unit, confirm that the amount actually added matches its setting.
If make-up has fallen, the answer is not to make the engine burn more oil. Repair a faulty automatic make-up unit and reset change intervals from the oil analysis trend. Where the engine maker allows it, an external oil tank can raise the total oil volume, and when changing oil, choose one from the approved list that holds its base number longer.
Hypothesis 4: oil runs too hot
When the cooling system falls short, the oil runs hotter and oxidises faster for it. Consider this hypothesis when the oil cooler or radiator is fouled, when a thermostatic valve has failed, when the engine room is poorly ventilated in midsummer, or when coolant temperature has been set high to recover more heat.
Since work on the heat recovery system, the engine outlet coolant has been running hotter than before. In the oil analyses since then, the oxidation value has started rising ahead of nitration, and viscosity is climbing with it.
Oil oxidation is a chemical reaction that speeds up as temperature rises. As oxidation proceeds, acid builds up in the oil, raising acid number and viscosity (Iwase et al., 2024), and base number falls as that acid is neutralised. Temperature also shifts the balance between oxidation and nitration. Organic nitrates, the nitration products in oil, decompose rapidly above 300 °F, about 149 °C, so in small high-speed four-stroke gas engines where cylinder wall temperature exceeds 320 °F, about 160 °C, oxidation is described as the main cause of oil deterioration (Exxon Mobil Corporation, 2009). The stationary gas engine oil study also counts temperature among the operating conditions that affect oil performance (Girshick, 2023).
Temperature can be measured directly. Take oil temperature and coolant temperature either side of the oil cooler and engine outlet coolant temperature from the operating records, compare them with the engine maker's ranges, and line them up with when oxidation and viscosity rose in the oil analyses. A shrinking temperature difference across the cooler points to fouling; temperatures that swing about point to the thermostatic valve.
If temperatures are out of range, bring them back first by cleaning the cooler, replacing the thermostatic valve and improving engine room ventilation. If coolant has to run hot for heat recovery, confirm that the temperature is within the engine maker's allowance, and choose an oil with high oxidation stability from the approved list. Once temperature is corrected, watch whether the oxidation slope flattens over the next few samples.
Hypothesis 5: wrong ash level
Gas engine oils range from almost ashless through low ash to medium ash, chosen by engine type and fuel. Typical cases are a low-ash oil chosen for natural gas used unchanged in a landfill gas or biogas engine, several engines sharing one oil tank, and a fuel change with no oil change.
Picture a plant where several natural gas engines and one biogas engine draw oil from the same tank. Set the reports side by side by engine, and only the biogas engine's base number falls unusually steeply.
Ash and base number share a root. The sulphated ash test is used to indicate the concentration of metal-bearing additives in new oil, with metals such as calcium and magnesium left as sulphates (ASTM International, 2023b). Calcium does the work of neutralising acid, and because the metal does not burn, it stays behind as ash once the oil has burnt. Too little ash lets valve faces and seats wear so that valves recede; too much lets ash built up in the valve gap break away, so that hot gas leaks past and can burn the valve face (Sutton, 2022). In deposits from landfill gas engines, too, calcium and zinc from oil additives were found alongside fuel impurities (Konkol et al., 2022). So a low-ash oil on an acid-rich fuel has little spare base to neutralise with and its base number runs down fast, while a high-ash oil on a clean fuel may keep its base number yet cause deposit trouble.
Check the sulphated ash and new-oil base number of the current oil in the TDS against the oil classes the engine maker allows for that fuel. Set base number slopes side by side for engines on the same oil and see whether only the engine on a different fuel drops fast. At overhauls, record valve recession and deposits in the combustion chamber and around the valves to judge whether ash is falling short or running over.
The answer is an oil of the right ash class for that fuel, chosen from the engine maker's approved list. If engines on different fuels share one tank, consider splitting the oil supply. Moving up to a higher-ash oil on base number alone can increase valve and combustion chamber deposits, so after the change, watch valve condition as well as base number.
Finding the cause
Start with what can be ruled out from oil analysis and operating records alone. Make-up, oil temperature and air/fuel settings are already on record, and fuel gas and infrared analyses need only a sample sent off. Leave valve and deposit checks that need the engine opened until an overhaul. First, confirm that base number was always measured by the same method, because values from the two methods are not interchangeable (ASTM International, 2026).
Next, see what moved with base number. If base number falls when gas quality worsened, with wear metals such as copper rising, look at sulphur and halogens in the fuel gas. If nitration rises in the infrared analysis, look at air/fuel ratio, load and blow-by; if oxidation and viscosity rise, look at oil temperature and the cooling system. If oxidation, nitration and fuel are all unchanged yet the slope has steepened, suspect a change in make-up or oil volume.
Comparing engines on the same oil helps too. If only the engine on a different fuel drops fast, look at the match between fuel and ash level; if one engine on the same fuel drops fast, look at that engine's temperature, air/fuel ratio, blow-by and make-up.
If that still does not settle it, change one thing at a time: fresh adsorbent in the treatment unit, then a cleaned cooler, then the air/fuel ratio back to setting, watching the base number slope over two or three samples after each. The job is done when the slope is back to its old level and acid number and wear metals are steady.
Hypotheses can overlap. An acid-rich fuel, a low-ash oil and low oil consumption together mean much acid coming in and little base going in. Hot oil speeds oxidation, and increased blow-by carries both fuel-borne acid and nitrogen oxides into the crankcase. In such cases, correct the acid sources such as fuel treatment and temperature first, then reset the oil's ash class and change interval, because the effect of an oil change cannot be compared fairly while the acid load is unsettled.
Limits and cautions
Base number and acid number change limits, allowable oil classes and ash levels, fuel gas specifications, and air/fuel ratio and coolant temperature ranges differ by engine type, maker and fuel, so numeric decisions follow the engine maker's limits and the oil's TDS. The standard's position is that base number condemning limits must be set empirically (ASTM International, 2026), so judge by a trend measured with one method rather than a single value. Fuel gas analysis, air/fuel adjustment and engine teardown findings are done together with a specialist laboratory and the engine maker or a service company.
Landfill gas and biogas can contain toxic hydrogen sulphide and the gas itself is explosive, so when sampling gas or opening treatment units, use gas detectors and ventilation and follow the site's permit-to-work procedure. Around a running engine, take care with the hot exhaust system and rotating parts. When handling oil and adsorbents, wear protective equipment as the product's safety data sheet, the SDS, requires, and dispose of used oil and spent adsorbent according to local regulations.
Sources
- Allen, M. R., Braithwaite, A., & Hills, C. C. (1997). Trace organic compounds in landfill gas at seven UK waste disposal sites. Environmental Science & Technology, 31(4), 1054–1061. https://doi.org/10.1021/es9605634
- ASTM International. (2022). ASTM D7624-22, Standard test method for condition monitoring of nitration in in-service petroleum and hydrocarbon-based lubricants by trend analysis using Fourier transform infrared (FT-IR) spectrometry. https://store.astm.org/d7624-22.html
- ASTM International. (2023a). ASTM E2412-23a, Standard practice for condition monitoring of in-service lubricants by trend analysis using Fourier transform infrared (FT-IR) spectrometry. https://store.astm.org/e2412-23a.html
- ASTM International. (2023b). ASTM D874-23, Standard test method for sulfated ash from lubricating oils and additives. https://store.astm.org/d0874-23.html
- ASTM International. (2026). ASTM D4739-26, Standard test method for base number determination by potentiometric hydrochloric acid titration. https://store.astm.org/d4739-26.html
- Bertinatto, R., Friedrich, L., Bariccatti, R. A., Souza, S. N. M., Gurgacz, F., & Pazuch, F. A. (2017). Analysis of lubricant oil contamination and degradation and wear of a biogas-fed Otto cycle engine. Acta Scientiarum. Technology, 39(4), 409–416. https://doi.org/10.4025/actascitechnol.v39i4.29458
- Exxon Mobil Corporation. (2009). Nitration of lubricating oil in natural gas engines [Technical topic]. https://www.mobil.com/lubricants/-/media/project/wep/mobil/mobil-row-us-1/new-pdf/tt-nitration-in-natural-gas-engines.pdf
- Girshick, F. (2023, July 4). Modelling gas engine oil life. Infineum Insight. https://www.infineuminsight.com/en-gb/articles/modelling-gas-engine-oil-life/
- Iwase, S., Maruyama, T., Momozono, S., Maegawa, S., & Itoigawa, F. (2024). Studies on dielectric spectroscopy of oxidatively degraded poly(α-olefin). Frontiers in Mechanical Engineering, 10, 1504347. https://doi.org/10.3389/fmech.2024.1504347
- Konkol, I., Cebula, J., Świerczek, L., Piechaczek-Wereszczyńska, M., & Cenian, A. (2022). Biogas pollution and mineral deposits formed on the elements of landfill gas engines. Materials, 15(7), 2408. https://doi.org/10.3390/ma15072408
- Muñoz, R., Meier, L., Diaz, I., & Jeison, D. (2015). A review on the state-of-the-art of physical/chemical and biological technologies for biogas upgrading. Reviews in Environmental Science and Bio/Technology, 14(4), 727–759. https://doi.org/10.1007/s11157-015-9379-1
- Prasad, M., & Lakshminarayanan, P. (2012). Estimation of oil drain life of engine oils in new generation diesel engines in tropical conditions. SAE International Journal of Fuels and Lubricants, 5(2), 576–592. https://doi.org/10.4271/2011-01-2405
- Rasi, S., Veijanen, A., & Rintala, J. (2007). Trace compounds of biogas from different biogas production plants. Energy, 32(8), 1375–1380. https://doi.org/10.1016/j.energy.2006.10.018
- Sutton, Z. (2022, June 23). Ash in stationary natural gas engines. Chevron Lubricants. https://www.chevronlubricants.com/en_us/home/learning/from-chevron/industrial-machinery/ash-in-stationary-natural-gas-engines.html