Applying another coat of the same product is the usual response when water repellency weakens, but if whatever wiped out the effect is still at work, the new layer tends to go the same way. What actually lies behind it can be abrasion from wiping and rubbing, contamination covering the surface, an unfinished cure, ultraviolet light or alkaline cleaners, and sometimes two or more at once.

Background

In the first week after application, water beads up and rolls off the glass or metal panel; a few weeks later it spreads into a thin film, runs off and leaves water spots where it dries. Inspection windows cloud over again, cladding panels and sensor windows need cleaning as often as before, and recoating costs material and labour once more. Where soiling blocks light and cuts output, as on solar module cover glass, losing a repellent surface to which dirt adhered poorly translates directly into cleaning costs and lost output (Lisco et al., 2020).

Whether water beads or spreads is decided by what is exposed at the very outermost surface. A water-repellent coating lowers surface energy by presenting groups that do not mix with water, such as fluorinated or alkyl chains, and silane treatments may tie those chains to the surface as a film a single molecule thick (Ulman, 1996). Roughness amplifies the effect. It makes a surface that already repelled water repel it more strongly (Wenzel, 1936), and when air is trapped in fine gaps beneath a drop, the drop rests on solid and air together and rolls off more easily (Cassie & Baxter, 1944). In other words, repellency hangs on a very thin outer layer and the fine texture beneath it, and once that layer is worn, covered or altered, the effect goes with it.

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: set areas that have lost the effect beside areas where it remains, such as edges out of reach or spots under a cover, compare drop shape and contact angle, then check the results against the initial values in the product's TDS and against the temperature, humidity and cure time recorded at application.

Hypothesis 1: abrasion

If the lost area follows the path of wiping, look at abrasion first. Windows swept by wipers, inspection windows and touch panels wiped daily with cloths or sponges, vehicle bodies passed by car-wash brushes and cladding struck by wind-blown sand are typical, and wear is faster when a dusty surface is rubbed with a dry cloth. Take one inspection window. Water spreads widely across the centre, where operators have wiped in circles out of habit, while the four corners their hands rarely reach still hold crisp beads.

Rubbing takes away both things that create repellency. The outer layer tied on one molecule thick is so thin that friction and scratching readily strip it, and the fine texture that trapped air is flattened from the peaks down. Because superhydrophobic surfaces rely on fine roughness, their mechanical weakness has long been a problem for the field (Verho et al., 2011), and a review of wear durability concludes that most superhydrophobic surfaces have very limited abrasion resistance and long-term durability, treating adhesion to the substrate, abrasion sliding across the surface and impact as distinct kinds of damage (Milionis et al., 2016). In repellent coatings for solar cover glass, loss of the nanoparticles that made up the roughness has also been observed (Lisco et al., 2020). A dusty cloth wears more for the same number of wipes, because the dust acts as an abrasive.

Begin by overlaying the wiping path on a map of where the effect is gone. Spray water, photograph the boundary where drop shape changes, and if a contact angle meter is available, measure on the wiping path and in the corners, following the standard practice for advancing contact angle, measured while the drop is grown (ASTM International, 2022). Ask operators what tool they wipe with, how hard, how often and whether the surface is dry. To compare candidate coatings for abrasion resistance, rub specimens a set number of cycles on the standard rotary abrasion tester (ASTM International, 2019) and compare the contact angle before and after.

If abrasion is the cause, change how the surface is cleaned first. Instead of dry wiping, rinse dust off with water and then wipe lightly with a soft cloth, and check wiper blade condition and pressure. Where wiping cannot be avoided, switch to a coating with abrasion test data, or measure how long the effect lasts and schedule reapplication before that point.

Hypothesis 2: surface contamination

When water spreads over a coating that has not worn, the question is what has covered the outer layer. Typical places are beside machining lines with oil mist, panels touched often by hand, surfaces washed with detergent and not rinsed enough, surfaces also treated with wax or silicone polish, and cladding where exhaust soot settles. If the surface was not clean before application, the coating may never have bonded properly in the first place. A partition window beside a press line shows the pattern. The coating is fairly new, yet a fingertip drawn across it feels a slick film, and sprayed water breaks into blotches as it runs down.

A drop sees not the coating but whatever sits at the very surface. Oil has a far lower surface tension than water, so it spreads readily into a film even on a surface that repels water (Tuteja et al., 2007). Surfactants in detergents adsorb with their water-hating tails against a water-hating surface and their water-loving heads facing out, so if rinsing falls short, a repellent surface turns into one that wets easily (Rosen & Kunjappu, 2012). Silane treatments must bond to hydroxyl groups on the substrate, and if oil or dust occupies those sites before application, the molecules cannot anchor or form an even film (Ulman, 1996).

The quickest check is to clean one small spot. Wipe part of the affected area with a neutral cleaner or solvent the TDS permits, rinse thoroughly with clean water, dry it, and see whether drops bead again. If only the cleaned spot recovers, the coating is still there and something was covering it; if it does not, the coating has worn or never bonded. Note nearby oil mist, hand contact, the detergent used and how it is rinsed, and any polish applied alongside.

When contamination is covering the coating, reduce its source and rinse more after cleaning. Fit shields or improve extraction where oil mist reaches, flush detergent away with plenty of clean water so no surfactant residue stays, and do not layer other polishes over the repellent coating. When reapplying, remove oil and dust as the TDS pretreatment directs, and confirm that water spreads evenly over the clean surface before coating.

Hypothesis 3: incomplete cure

If the effect dropped noticeably within days of application, suspect the cure. It happens when the weather is cold, when humidity is outside the TDS range, when the surface meets rain or washing before the set time has passed, when a thick coat was applied and the excess not wiped off, and when a heat-cure product was baked at a lower oven temperature or for less time. Picture a crew finishing exterior glazing outdoors on a late-autumn evening. Dew falls overnight, the routine wash runs as usual the next morning, and from the first week drops lie flat on that face alone.

Silane water repellents build a network through hydrolysis, in which alkoxy groups meet water and become silanols, and condensation, in which silanols join into siloxane bonds and release water. How fast this goes depends on the amount of water, the catalyst and the temperature, and condensation continues while the film dries and is heated (Brinker & Scherer, 1990). Bonding to the substrate forms through the same condensation, so molecules whose reaction is unfinished stay loosely tied to the substrate and to each other and are easily washed off at the first cleaning (Ulman, 1996). In a study of repellent coatings for solar cover glass, retained solvent moved through the film, blistering the surface and causing coating loss; the authors attributed it to insufficient curing and wrote that it can be avoided by carrying out specified curing conditions (Lisco et al., 2020).

The application records answer first. Check surface temperature and humidity at application, the time until first water contact or washing, and for heat-cure products the temperature and time the part actually reached, not the oven set point, against the TDS. If the same product was applied on another day under other conditions, compare the effect on that surface. Look under a magnifier for small blisters or lifted spots, and check the edges of the coated area for tacky residue.

When the cure looks to have fallen short, the next application starts by getting the conditions right. Apply within the TDS temperature and humidity range, keep the surface away from water and washing for the full cure time, and wipe off excess at the time the TDS specifies. For heat-cure products, fix a thermocouple to the part surface to confirm the actual temperature and time. An under-cured film is better stripped by the TDS method and reapplied than coated over, since the result is then easier to judge.

Hypothesis 4: UV degradation

Ultraviolet damage shows up as outdoor surfaces losing the effect from the side that gets the most sun. Where sunlight falls for long hours, such as south-facing glazing, solar module cover glass, vehicle sensor windows and outdoor instrument covers, the effect declines slowly with the hours of sun rather than dropping on particular days such as wash days. Compare glazing on one building coated on the same day by the same crew: on the north face, shaded by the eaves, drops still roll off, while on the south face, taking the full midday sun, water spreads and runs.

Ultraviolet light in sunlight breaks bonds in organic chains and lets them react with oxygen, detaching the groups that repelled water from the surface. In a study that exposed repellent coatings for solar cover glass to UV and damp heat in the laboratory, loss of surface fluorine emerged as a major issue, coatings tested outdoors had degraded surprisingly quickly, and the laboratory symptoms matched the outdoor results well (Lisco et al., 2020). Another study using xenon-arc accelerated weathering found the fluorine fraction in the coating falling as the contact angle fell. In the same study, the coating on borosilicate glass dropped below 90° after 2,000 hours and below 50° after 2,500 hours, while the same coating on hard-coated polycarbonate stayed above 100° even after 3,000 hours, which the authors read as degradation at the interface between coating and substrate (Lu et al., 2024).

Measuring sunlit and shaded surfaces on the same day by the same method reveals the share due to UV. Record contact angle or drop shape by orientation, remeasure every few months, and see whether the rate of decline tracks the amount of sun. If only the sunlit side declines, slowly, with no link to the wiping path or the detergent, UV is the likely cause. To compare products, put specimens coated on the same substrate into accelerated weathering and measure the contact angle at set intervals.

If UV is to blame, start by choosing a product with weathering data on a sunlit substrate. Because the same coating lasted very differently depending on the substrate and the layer beneath it, check that the test data come from the same substrate as the real one. Set a shorter reapplication interval for sun-exposed faces than for shaded ones, and refine it with the values measured in the first year.

Hypothesis 5: alkaline cleaners

An effect that falls in steps following the cleaning schedule points to the cleaner. Plant degreased with strong alkaline cleaners, food plant cladding foamed with alkaline cleaner every night and car washes using strong pre-wash detergent are typical, and attack is faster when the cleaner is mixed strong, left on longer or used hot. Stainless covers in a food plant carry a repellent coating, and from the night an alkaline foam cleaner comes into use, the drops grow a step flatter after every wash.

Silane coatings are linked to each other by siloxane bonds and attached to the substrate by bonds of the same kind, and these bonds can be broken by water, especially under alkaline conditions. A study comparing siloxane and phosphonate monolayers on a titanium alloy found the siloxane bonds hydrolysed readily in water and concluded that phosphonates are preferable where the surface meets even slightly alkaline water (Silverman et al., 2005). Silica itself dissolves much faster as pH rises (Iler, 1979), so silica-based coating layers, and the glass surface beneath a coating, are also eaten away by strong alkali. Repellent groups that have lost their anchor to the substrate are carried away at the next rinse.

Gather the cleaner's data sheet and conditions of use first. Record dilution, pH, temperature, contact time on the surface and rinsing method, and match the dates the effect dropped against the cleaning log. Compare surfaces the cleaner reaches with those it does not, and if spare coated specimens exist, soak them in the working dilution for a set time, rinse, and measure contact angle before and after to isolate the cleaner's share.

If alkali is responsible, move the cleaning conditions into the range the coating can stand. Switch to a cleaner within the pH range the TDS recommends; where the process truly needs strong alkali, lower concentration, temperature and contact time, then rinse thoroughly with clean water. For plant whose cleaning cannot change, ask the supplier for a coating with test data under those alkaline conditions.

Finding the cause

Much of the sorting among five hypotheses needs no equipment. A water spray bottle is enough to draw the boundary of the lost effect, and application and cleaning records are already in hand. Cleaning a small test spot takes a few minutes, so do these three first and leave contact angle measurement and specimen tests for afterwards.

The pattern of loss is the first clue. Loss along the wiping path or the sweep of a wiper points to abrasion, a slow decline that follows sun exposure points to UV, and step-wise drops matching the cleaning dates point to alkaline cleaners. If the whole coated area weakened evenly within the first few days, look at the cure; if water spreads in blotches and a film can be felt with a fingertip, look at contamination.

The cleaning test is the next fork. If the effect returns where the spot was cleaned, the coating is still there and covered, so pursue contamination and detergent residue; if it does not, the coating has gone or changed, so look at abrasion, cure, UV and alkali. If that still does not settle it, run control trials that change one thing at a time: change the cleaner on one face only, or the wiping method, or fit a shield, and after a few weeks measure both sides the same way.

The final check is how the recoated surface holds up. After fixing the cause and reapplying, measure contact angle right after application and at set intervals, and see whether the effect now declines more slowly than before. Judging from the initial value alone does not show whether the cause has been fixed.

The hypotheses can overlap. An outer layer weakened by UV comes off more easily when wiped, an under-cured film is also more vulnerable to alkaline cleaning, and scrubbing hard or using strong detergent to remove contamination adds abrasion and alkali at once. In such cases, put right first what can be changed by hand, such as application conditions and cleaning method, and then treat any remaining loss as a question of UV or product choice, because while cleaning and application are unsettled, differences between products cannot be compared fairly.

Limits and cautions

The chemistry of a repellent, its proper cure conditions, the pH range it tolerates and suitable cleaning differ by product and substrate, so numeric decisions follow the product's TDS and the supplier's test data. Compare contact angles only between readings taken with the same instrument and method, and use drop shape judged by eye only to see trends. On regulated surfaces, such as food-contact surfaces, medical devices or vehicle safety sensors, confirm with the applicable rules and the quality engineer before changing coating or cleaner.

For repellents, cleaners and solvents, follow each product's safety data sheet, the SDS, for protective equipment and ventilation. Avoid breathing the mist from spray-applied repellents, protect eyes and skin from strong alkaline cleaners, and never mix them with acidic products. Before testing glazing or panels at height, put fall protection in place first.

Sources

  1. ASTM International. (2019). ASTM D4060-19, Standard test method for abrasion resistance of organic coatings by the Taber abraser. https://store.astm.org/d4060-19.html
  2. ASTM International. (2022). ASTM D7334-08(2022), Standard practice for surface wettability of coatings, substrates and pigments by advancing contact angle measurement. https://store.astm.org/d7334-08r22.html
  3. Brinker, C. J., & Scherer, G. W. (1990). Sol-gel science: The physics and chemistry of sol-gel processing. Academic Press. https://doi.org/10.1016/C2009-0-22386-5
  4. Cassie, A. B. D., & Baxter, S. (1944). Wettability of porous surfaces. Transactions of the Faraday Society, 40, 546–551. https://doi.org/10.1039/tf9444000546
  5. Iler, R. K. (1979). The chemistry of silica: Solubility, polymerization, colloid and surface properties, and biochemistry. Wiley.
  6. Lisco, F., Bukhari, F., Uličná, S., Isbilir, K., Barth, K. L., Taylor, A., & Walls, J. M. (2020). Degradation of hydrophobic, anti-soiling coatings for solar module cover glass. Energies, 13(15), 3811. https://doi.org/10.3390/en13153811
  7. Lu, S., Zhao, Y., & Hellerman, E. A. P. (2024). UV-durable self-cleaning coatings for autonomous driving. Scientific Reports, 14, 8066. https://doi.org/10.1038/s41598-024-58549-y
  8. Milionis, A., Loth, E., & Bayer, I. S. (2016). Recent advances in the mechanical durability of superhydrophobic materials. Advances in Colloid and Interface Science, 229, 57–79. https://doi.org/10.1016/j.cis.2015.12.007
  9. Rosen, M. J., & Kunjappu, J. T. (2012). Surfactants and interfacial phenomena (4th ed.). Wiley. https://doi.org/10.1002/9781118228920
  10. Silverman, B. M., Wieghaus, K. A., & Schwartz, J. (2005). Comparative properties of siloxane vs phosphonate monolayers on a key titanium alloy. Langmuir, 21(1), 225–228. https://doi.org/10.1021/la048227l
  11. Tuteja, A., Choi, W., Ma, M., Mabry, J. M., Mazzella, S. A., Rutledge, G. C., McKinley, G. H., & Cohen, R. E. (2007). Designing superoleophobic surfaces. Science, 318(5856), 1618–1622. https://doi.org/10.1126/science.1148326
  12. Ulman, A. (1996). Formation and structure of self-assembled monolayers. Chemical Reviews, 96(4), 1533–1554. https://doi.org/10.1021/cr9502357
  13. Verho, T., Bower, C., Andrew, P., Franssila, S., Ikkala, O., & Ras, R. H. A. (2011). Mechanically durable superhydrophobic surfaces. Advanced Materials, 23(5), 673–678. https://doi.org/10.1002/adma.201003129
  14. Wenzel, R. N. (1936). Resistance of solid surfaces to wetting by water. Industrial & Engineering Chemistry, 28(8), 988–994. https://doi.org/10.1021/ie50320a024

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.