Why do bubble tests show leaks that are not there?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Detection & Utilities

Retightening the joint or replacing the part is the usual response when bubbles appear, but bubbles can come from the fluid itself or the conditions around it with no gas escaping at all. What actually produces them can be foam applied along with the fluid, air trapped in gaps and rough surfaces, vibration and wind, a change in temperature or too much fluid, and sometimes two or more at once.

Background

With pressure on an assembled valve block, leak detection fluid goes on and bubbles form at a threaded joint. The operator calls it a leak, undoes the joint, reseals it, tightens it and tests again, and bubbles show again. Only after the part has been replaced does the thought arise that the first one may have been sound. A false leak call costs the time to rework and retest, scraps good parts, and damages threads and sealing faces through undoing and retightening, and when such calls repeat, the bubble test itself becomes hard to trust.

A bubble test creates a pressure difference across a wall so that gas from the high side passes through any leak path and inflates the liquid film on the low side. It is used to find where leaks are and give a pass or fail, not to measure how much leaks (ASTM International, 2022b). The criterion is not whether a bubble appears but whether bubbles keep growing at the same spot: ASME treats continuous bubble growth on the surface as the sign of a leak (ASME, 2004). A test fluid should bubble only in response to leakage, but a contaminated fluid or one that foams as it goes on can produce bubbles on the surface that have nothing to do with a leak (LANL, 2018).

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: mark the spot where bubbles appeared, and compare the pressure, hold time, surface temperature and application method in the fluid's technical data sheet, the TDS, and in the procedure with what was actually done at the time.

Hypothesis 1: application foam

Foam made during application can be mistaken for leak bubbles when fluid is sprayed hard, when the bottle is shaken before use, when it is scrubbed on with a brush, or when the fluid is cleaning detergent mixed with water. At the first test of the morning, an operator shakes a spray bottle that has stood overnight a few times, holds it right up to the joint and sprays hard. The joint is covered white with fine froth, and here and there a few large bubbles swell and burst.

Foam forms when air is mixed into a surfactant solution, and the surfactant supports the foam films so they last for a while (Pugh, 1996). Spraying, shaking and scrubbing all mix air into the fluid, so bubbles unrelated to any leak sit on the surface from the start. Among them, bubbles made by escaping gas are hard to pick out. ASME requires the bubbles in the solution to be kept to a minimum so that existing bubbles and leak bubbles can be told apart (ASME, 2004), and one public laboratory's procedure rejects household detergent and water as a test fluid because foam masks leaks and lowers sensitivity (LANL, 2018).

Watch how the bubbles behave just after application. Foam from application forms all at once and stays the same size or shrinks and bursts where it sits, while a leak bubble forms anew at the same point and grows. Spraying the same way onto an identical part without pressure, or onto a smooth plate, shows straight away how much foam the method of application makes by itself.

Change the method of application first. The procedure allows the solution to be flowed, sprayed or brushed on (LANL, 2018), so pick whichever makes less foam. Do not shake the bottle, spray gently from a distance, and lay the fluid on with the brush rather than scrubbing. Use a fluid made for leak testing instead of detergent soapy water, and look at the same spot again once the first foam has settled.

Hypothesis 2: trapped air

If bubbles appear where air has plenty of places to hide, such as threaded joints, around the sleeve of a compression fitting, the ripples of a weld bead, the rough skin of a casting, lifted rust or paint, or the edge of a gasket, look here first. Brush fluid onto a threaded plug in a rough cast valve body, for instance, and for the first few seconds a line of small bubbles rises along the threads. On the smoothly machined faces of the same body, no such bubbles appear.

Dry gaps and the hollows of a rough surface hold air. When fluid covers them and soaks in, the air is pushed out and forms bubbles. A review of bubble formation from gas pockets concludes that the bubbles seen in a liquid holding more dissolved gas than it can keep generally start from gas pockets already present in cracks and pits in the wall, and that without such pockets bubbles need a very high degree of supersaturation to form (Jones et al., 1999). According to the same review, while the liquid stays supersaturated a bubble can form, grow and detach over and over at one such point. Bubbles coming one after another from a single point look much like a leak. Surface contaminants can also make bubbles of their own and suggest a leak that is not there (LANL, 2018).

Timing is the clue. See whether bubbles come only just after application and then stop, or keep growing at the same point as time passes. If they stopped, wipe the spot and wet it again. The trapped air has already escaped, so the second time there may be far fewer bubbles, while a leak grows bubbles again at the same point. Compare too how bubbles behave on rough and smooth surfaces. Looking at the point where the bubbles come from with a magnifier shows whether it is a place where air could hide, such as a thread root or a small pore in a cast surface.

The remedy lies in preparation. Clean and dry the surfaces inside and out before the test to remove debris and moisture, and apply pressure before the fluid goes on (NASA, 2023). Remove rust, lifted paint and weld slag, and after application wait for the first bubbles to stop, then judge by whether bubbles keep growing at the same point.

Hypothesis 3: vibration and wind

Suspect vibration and wind if the test was done on outdoor piping, near a draughty doorway, in front of a ventilation duct or cooling fan, beside a running compressor or pump, or in an aisle with forklift traffic. On a windy afternoon, fluid goes onto a flange on the rooftop cooling water line, and the froth is pushed to the downwind edge and gathers there, where bubbles burst and form again in quick succession. Each time the cooling fan next to it runs, the pipe trembles slightly.

Wind dries the liquid film quickly. In soap film experiments, films burst when thinning by evaporation became comparable to thinning by drainage, and films lasted longer at higher humidity (Champougny et al., 2018). In a drying wind, films burst and new ones form over and over, and that movement can look like bubbles forming continuously. Wind also pushes surface froth to one side, so the edge where it gathers looks like the place of a leak. Vibration shakes the liquid and mixes air into it, making fresh foam. ASME requires the solution to form a film that does not break away from the test area, with bubbles that do not burst quickly from drying in air (ASME, 2004).

Put up a windbreak or hold a portable screen in place, stop the nearby source of vibration for a moment, and look at the same spot again. Bubbles that vanish or wander about once screened were made by vibration and wind. If one point keeps swelling even behind the screen, suspect a leak. Record as well whether the place where bubbles gather shifts with the wind direction, and whether it changes when the vibration source runs and stops.

When wind and vibration turn out to be the cause, cut off their effect at least while the call is being made. Outdoors, set up a windbreak or test when the wind has dropped, and near a vibration source agree with operations whether the equipment can be stopped during the check. If the fluid dries quickly, apply a fresh thin coat just before judging, and where the wind is always strong, ask the supplier whether a fluid made for longer-lasting films is available.

Hypothesis 4: temperature shift

Stray bubbles can appear when the part, the fluid and the surroundings are at different temperatures, as with outdoor piping in sunshine, a part just welded or straight from the process, or fluid fresh from a cool store. A nozzle on an outdoor tank has been baking in the midsummer sun when fluid fresh from a cool store is applied to it. Fine bubbles start to rise not only at the joint but all over the smooth surface.

Water holds a little dissolved air, and the amount it can hold falls as temperature rises (Sander, 2015). When cold fluid warms up on a hot surface, the dissolved air exceeds what the fluid can hold, and the excess escapes as bubbles through gas pockets in small cracks and hollows in the surface (Jones et al., 1999). Air trapped in gaps also expands as it warms and is pushed out. ASME requires the surface temperature to stay between 5 °C and 50 °C throughout the examination, and the solution to suit the temperature of the test conditions (ASME, 2004).

Measure the temperatures of the part surface, the fluid and the surroundings. Bubbles that rise evenly over a wide area, smooth surfaces included, and dwindle with time point to temperature, while bubbles that grow steadily at one point only point to a leak. Once temperatures have evened out, wipe the spot, apply again and compare with the first result. Check too whether bubbles behave differently on the shaded and sunlit sides. Where a pressure gauge is also read, the gas inside the part changes in volume and pressure with temperature, so changes in ambient temperature must be allowed for in the calculation (NASA, 2023).

The first remedy is time: let the part and the fluid reach the same temperature. Shade the part from direct sun or test when the sun is weaker, and bring the fluid to workshop temperature before use. If the surface temperature is outside the procedure's range, judge only once it is back within it.

Hypothesis 5: too much fluid

Consider this hypothesis when fluid is sprayed over the same spot several times, when a whole joint is drenched, or when fluid runs down to hang in drops and pool on the underside. Wanting to be sure, an operator sprays round a flange again and again. The fluid forms a thick coat, then runs down to hang in drops under the bolt heads, and bubbles keep showing in those drops and in the fluid pooled below.

A thick layer of fluid drains under its own weight and thins (Champougny et al., 2018). The draining fluid drags froth down from above and leaves it at the lower edges and in the drops. Each extra pass mixes in more air and thickens the froth, and in thick froth it is hard to find where a bubble started. The amount applied has a standard too. The NASA standard requires foam-type fluid to cover the test area with a blanket of foam 3 to 7 mm thick, and liquid fluid to be applied evenly (NASA, 2023).

Telling this apart is simple. Wipe the wet area, apply one thin, even coat, and look at the same spot. If bubbles showed only in drops and pooled fluid and are gone after the thin recoat, the amount was the problem. A point that grows bubbles again even under the thin coat stays on the list as a possible leak. Check as well whether the bubbles sat low down, where running fluid collects.

Write the amount to apply into the procedure. Cover in one thin, even coat, wipe off before any second pass, and wipe away hanging drops before judging. Inspect undersides with a lamp and a hinged mirror instead of applying more fluid (NASA, 2023).

Finding the cause

The surest separator is pressure. A bubble test pushes gas out by means of a pressure difference across the wall (ASTM International, 2022b), so bubbles that still form at the same spot with the pressure fully released do not come from a leak. Releasing the pressure, wiping the area and applying fluid the same way is easy to do and is the first step in picking out false bubbles.

Next is how the bubbles look. Leak bubbles form anew at the same point and grow. Fine froth that appears all over the surface the moment the fluid goes on is application foam, and bubbles that come out along gaps and threads just after application and then stop are trapped air. Bubbles that crowd to the downwind edge or shake in time with vibration point to vibration and wind, bubbles that rise widely, smooth surfaces included, and dwindle over time to a temperature difference, and bubbles seen only in drops and pooled fluid to too much fluid. Reading these patterns needs good light. One public laboratory's procedure sets the light at the surface being judged at no less than 100 fc, about 1,076 lux, so it is better to set up lighting first than to strain up close in a dim spot (LANL, 2018).

If it is still unclear, run a comparison. Set an identical part without pressure alongside and apply the same fluid in the same way at the same place. If both parts show the same bubbles, the conditions made them; if a point keeps growing on the pressurised part only, it is a leak. Change only one condition at a time, or there is no telling which one made the false bubbles.

Where the calls disagree, confirm once more by another method. Leak testing methods are meant to be chosen by weighing sensitivity, cost and reliability (ASTM International, 2022a), so adding a method that does not rely on bubbles, such as a pressure hold test, means the decision no longer rests on a single bubble. Record the result together with the marked spot.

The hypotheses can overlap. Spraying repeatedly outdoors in sun and wind brings temperature, wind, application foam and amount into play together. In such cases, calm the conditions first with shade and a windbreak, bring part and fluid to the same temperature, then apply one thin coat and judge. If bubbles still keep growing at the same point once the conditions are settled, treat it as a leak.

Limits and cautions

Steps to cut false bubbles must not let a real leak slip through. The normal sensitivity limit of a bubble test is about 1×10⁻⁵ std cm³/s (ASTM International, 2022b), so parts that must be screened for smaller leaks need another method. Values such as pressure, hold time, surface temperature and amount applied follow the fluid's TDS, the governing standard and the procedure. Writing into the procedure a single check with the pressure released before any joint is retightened or part replaced on a leak call cuts the number of good parts thrown away.

Safety matters too. The UK Health and Safety Executive regards close observation of a pressurised assembly as a significant risk even when the test pressure has been reduced well beforehand, calls for the need for close inspection to be removed wherever possible, and requires the pressure to be reduced significantly before any close observation (HSE, 2012). Retighten or undo a joint that showed bubbles only after releasing the pressure, handle the test fluid according to its safety data sheet, the SDS, and rinse it off once the test is over.

Sources

  1. American Society of Mechanical Engineers [ASME]. (2004). ASME boiler and pressure vessel code, Section V: Nondestructive examination, Article 10, Leak testing. ASME.
  2. ASTM International. (2022a). ASTM E432-91(2022), Standard guide for selection of a leak testing method. https://store.astm.org/e0432-91r22.html
  3. ASTM International. (2022b). ASTM E515-11(2022), Standard practice for leaks using bubble emission techniques. https://store.astm.org/e0515-11r22.html
  4. Champougny, L., Miguet, J., Henaff, R., Restagno, F., Boulogne, F., & Rio, E. (2018). Influence of evaporation on soap film rupture. Langmuir, 34(10), 3221–3227. https://doi.org/10.1021/acs.langmuir.7b04235
  5. Health and Safety Executive [HSE]. (2012). GS4, Safety requirements for pressure testing (4th ed.). https://www.hse.gov.uk/pubns/gs4.pdf
  6. Jones, S. F., Evans, G. M., & Galvin, K. P. (1999). Bubble nucleation from gas cavities: A review. Advances in Colloid and Interface Science, 80(1), 27–50. https://doi.org/10.1016/S0001-8686(98)00074-8
  7. Los Alamos National Laboratory [LANL]. (2018). ITM-1306-NDE-LT-101, Bubble leak testing: Direct pressure & vacuum box (Rev. 0). LANL Engineering Standards Manual STD-342-100. https://engstandards.lanl.gov/esm/welding/vol6/ITM-1306-NDE-LT-101-R0.pdf
  8. National Aeronautics and Space Administration [NASA]. (2023). NASA-STD-7012A, Leak test requirements. https://standards.nasa.gov/sites/default/files/standards/NASA/A/0/2023-02-22-NASA-STD-7012A-Approved.pdf
  9. Pugh, R. J. (1996). Foaming, foam films, antifoaming and defoaming. Advances in Colloid and Interface Science, 64, 67–142. https://doi.org/10.1016/0001-8686(95)00280-4
  10. Sander, R. (2015). Compilation of Henry's law constants (version 4.0) for water as solvent. Atmospheric Chemistry and Physics, 15(8), 4399–4981. https://doi.org/10.5194/acp-15-4399-2015

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.