Adding extinguishers or switching to an oil with a higher flash point is the usual response to fires on machines running neat cutting oil, but a fire needs fuel and an ignition source in the same place, so fixing only one side tends to let it return. What actually lies behind it can be a low flash point oil, mist filling the machine, dull or broken tools, fluid that misses the cut, sparks reaching oil built up in the extraction, or detection that comes late during unattended running, and sometimes two or more at once.

Background

A dull thud sounds inside an enclosed machine tool, flames escape through the door gap, and the machine fills with smoke. Most such events stay as small local fires that are quickly brought under control, but in severe cases operators are burned and the damage to property can be heavy (DGUV, 2020). Even after the fire is out the machine stands idle, and while burnt wiring, hydraulic hoses, windows and sensors are replaced, its work has to be moved elsewhere.

Neat cutting oil, oil used as supplied rather than diluted with water, is a combustible liquid. During machining it turns into vapour and fog-like mist that fills the machine, and when an ignition source meets this oil-air mixture, a low-pressure explosion, a flash, can occur and lead on to fire. Such events start mainly from tool breakage, faulty control movements or tools running dry, with glowing chips and hot surfaces acting as ignition sources (DGUV, 2020). A German machine tool industry survey of about 150 fires in metalworking likewise traced them to tool breakage, insufficient coolant supply, faulty movements, jammed workpieces, cable faults and sparks from electrostatic oil mist separators, among others (DGUV, 2012).

So the routes to a fire come down to two: more of the oil and mist that burn, or an ignition source that reaches them. Whether the fire grows is a further question that depends on how fast it is noticed and put out. Where the first flame was seen and what the machine was doing at the time are the clues that narrow the cause.

In such cases the technical team sets up the six hypotheses below and rules them out one by one. The start is always the same: secure the part program, tool number, spindle load and alarm log at the time of the fire, take a sample of the cutting oil in use, and compare its flash point and viscosity with the product's technical data sheet, the TDS, and safety data sheet, the SDS.

Hypothesis 1: low flash point oil

Processes where oil must get into narrow gaps, such as deep-hole drilling, grinding and honing, often run low-viscosity oils, and low-viscosity oils sit towards the low end of flash point. Pouring cleaners or kerosene into the tank, or topping up with oil from another machine, tips things the same way. Kerosene used for washing parts has been trickling into a honing machine's tank that is never emptied, and over a few months the cutting oil has come to smell sharper than it used to.

Flash point is the lowest temperature at which vapour from heated oil briefly catches fire when a flame is applied, and for high flash point oils such as neat cutting oils it can be measured by the Cleveland open cup method (ISO, 2017). A table in the German statutory accident insurance guidance shows flash point falling and evaporation loss at 250 °C rising as viscosity grade goes down, with the thinnest grade given as a flash point above 120 °C and an evaporation loss below 85%. The same guidance advises choosing the oil with the lowest evaporation loss and the highest flash point and viscosity the process allows, and notes that liquid fires are easier to contain the higher the viscosity and flash point (DGUV, 2012). A high flash point is not a guarantee, though. Mists can burn below the flash point, and a review found flash point to be no useful measure of the temperature at which a spray ignites on a hot surface (Gant, 2013).

Measuring the flash point of in-use oil and fresh oil by the same method shows in numbers whether something has got in. If the in-use oil's flash point is clearly lower than the fresh oil's, volatile material has entered; check whether viscosity has dropped with it. Go through the top-up records for what went into the tank and when, and ask whether anyone pours cleaners or other oils into it. In Korea, oils with a flash point from 70 °C to below 200 °C are classed as third petroleum products and those from 200 °C to below 250 °C as fourth petroleum products (MOLEG, n.d.), so check the flash point and class on the SDS as well.

If flash point is part of the cause, correct two things. One is stopping what gets mixed in. Never pour cleaners or volatile liquids into the cutting oil tank (DGUV, 2020), and replace oil that is already contaminated. The other is oil selection. Trial a move to the highest viscosity grade the process can tolerate and a base oil with low evaporation loss with the supplier, but since higher viscosity can reduce filterability and delivery, look at filter and pump conditions at the same time.

Hypothesis 2: mist in the machine

The inside of a machine turns hazy with high-speed machining at raised spindle speeds, deep-hole drilling with high-pressure coolant, high oil temperature as in summer, and a weakened mist extraction unit. Every time the door opens at the end of a cycle, white fog rolls out, oil beads and runs down the inside of the window, and the floor around the machine is always slippery.

Mist forms in two ways. Sprays break up into fine droplets, and oil evaporates at the hot cutting zone and condenses as it cools. In a study that measured mist in turning, spindle speed had the dominant effect on mist mass concentration and particle size (Michalek et al., 2003), and a review of machining mist studies noted that mist concentrations while cutting were 14 to 400 times higher than without cutting, pointing to evaporation and condensation as the main source (Gant, 2013). German statutory accident insurance guidance cites findings that a 10 °C rise in coolant temperature doubles mist generation and gives the lower explosion limit of coolant mist as 25 to 60 grams per cubic metre (DGUV, 2021).

Checking starts at the extraction unit. Confirm from an airflow meter or pressure switch records that it delivers the minimum extraction flow set by the maker, and inspect for clogged filters and damaged ducts. Measure oil temperature in the tank and at the nozzle exit, and record how far it rises with season and running time. Photograph whether fog comes out when the door opens and whether oil beads on the window, to compare before and after any fix.

If mist is heavy, make less and remove more. Review a move to oil with anti-mist additive, or to oil based on low-evaporation mineral oil or synthetic ester, and lower the temperature with an oil cooler. Place the extraction inlet far from the cutting zone and fit a baffle plate or pre-separator in front of it so chips and large droplets stay out of the duct (DGUV, 2021). Interlock the extraction so the machine stops when airflow drops below the set value.

Hypothesis 3: dull or broken tools

Watch for this on days when tools run past their life, on days the material is changed to a harder one, right after a switch to a new tool supplier, and on shifts where tool records have fallen behind. On a night shift with a drill nearing the end of its life, chips from one hole turn from silver to dark blue, spindle load creeps up, and the drill snaps with a sharp crack. Moments later a small flame flickers up around the cutting zone.

A dull edge needs more force to do the same work, and that work turns into heat. The German statutory accident insurance guidance regards an overheated tool or tool breakage as the most common cause of machine tool fires and explains that a worn drill can raise the temperature at the cutting zone sharply enough to act as an ignition source (DGUV, 2012). At the moment of breakage, the edge scrapes the workpiece and throws glowing chips and strong sparks, and a spindle that keeps turning without its tool runs dry and creates hot surfaces. The same body's summary that most fires begin at the cutting zone with a glowing chip, a grinding spark or an overheated tool fits this picture (DGUV, 2021).

The records say the most. Compare the hours and part count on the tool involved with its life limit, and look at the spindle load trend over the minutes before the fire. A load that crept up and then spiked suggests breakage after wear; a sudden spike suggests a crash or jam. Check also whether parts from the same tool number showed changed chip colour or rougher surfaces.

For a tool problem, put two things in place: life management and monitoring. Replace tools when the maker's stated life has run out, and install process monitoring that watches spindle power or the structure-borne sound of cutting and stops the machine when it detects wear or breakage (DGUV, 2012). Set the monitoring limits from load records of normal cutting, and interlock the alarm to retract the tool and stop the spindle.

Hypothesis 4: fluid misses the cut

Oil that flows but never reaches the cutting zone neither cools it nor smothers sparks. This happens when nozzles are knocked during a setup change, when tool length changes but nozzle aim stays the same, when a clogged filter or low tank level makes the pump draw air, and when the passage carrying oil through the tool is blocked. One afternoon after a switch to a longer drill, the nozzle jet still runs strong, but it hits the side of the holder rather than the drill tip.

Insufficient coolant supply was named alongside tool breakage among the causes found in the German industry fire survey (DGUV, 2012). The cutting zone has to be covered with ample oil for heat to leave the chip and edge and for sparks to go out, and the same body explains that flooding close to the tool with large volumes at low pressure, 2 to 4 bar, works best, with jet pressure, nozzle shape and aim setting both cooling and how much mist forms (DGUV, 2021). When the nozzle misses, the cutting zone heats up dry, and a jet striking the wrong place only adds mist.

After every setup, check by eye that the nozzles aim at the tool tip, and for processes where tool length varies widely, record nozzle positions per tool. Measure pressure, flow and pump motor current at the pump outlet against normal values, and look at filter differential pressure and tank level as well. If the process that caught fire feeds oil through the tool, confirm that the tool passage is not blocked.

On the supply side, the core fix is monitoring. Watch coolant supply with pressure switches, flow monitors or pump motor current, and when supply fails have the control retract the tool from the workpiece and stop the spindle (DGUV, 2012). Re-aim the nozzles to flood the cutting zone close to the tool, and on machines where nozzle aim can be set per tool in the program, put that value into the tool data. Set limits for tank level and filter change intervals too.

Hypothesis 5: sparks reach oily ducts

Grinding throws sparks as the wheel tears off countless small chips, and over time oil and grinding sludge build up inside the ducts and mist collectors that draw away that air. The risk grows when collector cleaning has fallen behind, when a sagging duct has low spots where oil pools, and when the electrodes of an electrostatic collector are dirty. Black oil seeps from duct joints running above the grinder, and opening the collector reveals a thick, sticky residue on the filters and walls.

Grinding sparks are a typical ignition source at the cutting zone, and the German statutory accident insurance body gives the example of quenching them with extra oil at their point of origin, the lower nozzle in grinding (DGUV, 2021). Sparks or hot chips that are not put out and get drawn into the extraction duct find fresh fuel in the oil built up in the ducts and collector. German guidance holds that if an ignition source can pass through the extraction duct into the collector, the collector must be included in the extinguishing concept, and sparks from electrostatic collectors appeared among the causes in the fire survey (DGUV, 2012). Fire tests also showed that without countermeasures, flames must be expected to pass into the extraction system (DGUV, 2020).

Look inside the ducts and collector. Open the inspection ports, check how thick the oil and sludge layer is inside the duct, and mark sagging or dipped sections. Compare cleaning records for collector filters and electrostatic electrodes with the maker's recommended intervals, and check the operating log for frequent spark-over at the electrodes. Oil-air mixtures can be ignited by electrical sparks of less than 10 joules (IFA, n.d.), so frequent spark-over is a warning in itself. Watch through the window during a cycle whether grinding sparks fly towards the extraction inlet.

Set and keep cleaning intervals so that built-up oil is never left waiting for a spark. Make ducts of non-combustible, earthed material, slope them so oil cannot pool, and fit inspection ports. Put a baffle plate or pre-separator in front of the inlet to catch sparks and chips, and consider fast-closing shut-off dampers and flame arresters so fire cannot spread along the duct (DGUV, 2021). Decide with the equipment supplier whether to add fire detection and an extinguishing nozzle inside the collector as well.

Hypothesis 6: unattended, seen late

Creating a spark and letting a fire grow are separate problems. On machines run unattended at night or over weekends, in cells where one person minds several machines, and on machines with no fire detection or only manually triggered extinguishing, a fire cannot be put out while it is small. The morning after unattended running was left on overnight on a Friday, one machine's window is blackened and the chip bin and oil tray have burned too.

The higher the risk, the more detection and extinguishing need to be automatic. German guidance allows manual extinguishing only where the risk is low and unattended running is not possible, and describes an automatic system as fire detectors in the work area and at places such as the extraction and chip conveyor, a control unit for alarm and machine shutdown, and a manual release (DGUV, 2012). The international standard sets out how to assess a machine's fire risk and choose protective measures such as detection and extinguishing (ISO, 2019), and the German statutory accident insurance body advises that the machine should start only when extraction is running, the door is locked and the extinguishing system is ready (DGUV, 2021). Brim-full oil trays, large gratings, pools of oil and oily rags become routes for fire to spread beyond the machine.

There are three things to check: whether each machine has fire detection, whether the detection signal leads to alarm, spindle stop, extraction shutdown and extinguishing release, and whether there is a record of that chain actually being tested. Confirm from records who receives the alarm during unattended hours and how many minutes it takes them to reach the machine. Walk around the machine to see how oil trays, chip bins, cardboard and rags are placed.

To keep running unattended, the fire has to be put out with no one there. Fit automatic detection and extinguishing first to the machines that run unattended, and test their operation regularly. Empty chip bins and oil trays at set intervals, and keep oily rags in closed, non-combustible bins. Carbon dioxide extinguishing harms health from 5% concentration and endangers life above 8% (DGUV, 2021), so always lock out the extinguishing system before entering the machine.

Finding the cause

Rather than six separate investigations, start with the records of the moment the fire broke out. The part program, tool number, spindle load and coolant supply alarms are stored in the control, and a laboratory can return the flash point and viscosity of an oil sample within days. The inside of ducts and collectors can only be seen with the machine stopped, so they come next.

The first clue is where the flame was first seen. A fire that began at the cutting zone points first to tool condition and whether the fluid was reaching the cut; one that began in a duct or collector points to built-up oil and sparks carried into it. A flash at the moment the door opened or at the end of a cycle shifts the weight towards mist in the machine and the oil's flash point. A fire that started small and spread beyond the machine was detected and fought too late.

Next are the records just before. A spindle load that crept up and spiked points to tool wear and breakage; a fall in coolant pressure beforehand points to supply and nozzles. If smoke and fog on the same machine grew with season or running time, look at oil temperature and extraction; if something was added to the tank just before, suspect the oil's composition.

If that still does not settle it, change one thing at a time. Lower only the oil temperature with a cooler and see whether the fog lessens; re-aim only the nozzles and see whether chip colour and tool life change. Only one change at a time shows which one worked. Afterwards, count alarms, smoke and small flames on the same basis as before the change.

The hypotheses can overlap. A nozzle that misses lets the cutting zone run hot and dry so the tool wears faster, a worn tool runs hotter and makes more mist, and that mist builds up as oil in the ducts. In such cases, put right coolant supply and tool management, which cut down the ignition sources, first, and then look at the oil and extraction, because while sparks keep forming, the effect of changing the oil cannot be compared fairly. Detection and extinguishing, though, come first even while the cause is still being sought.

Limits and cautions

Suitable flash point, viscosity, evaporation loss, coolant pressure and flow, extraction airflow, and type and quantity of extinguishing agent differ by machine, process and material, so numeric decisions follow the oil's TDS and SDS and the guidance of the machine tool and fire system makers. Metals such as magnesium and titanium can themselves burn as metal fires that ordinary extinguishing agents cannot put out (DGUV, 2021), so they need separate expert judgement. Storage and handling of combustible liquids follow local dangerous goods rules.

Safety matters too. Do not open the door of a machine that is on fire, do not restart a machine straight after a fire, and do not work in oil-soaked clothing (DGUV, 2020). Flammability is an important consideration for neat cutting oils, and such systems may need fire protection (OSHA, n.d.). Mist is a health issue as well as a fire issue, and the U.S. National Institute for Occupational Safety and Health set a recommended exposure limit for metalworking fluid aerosols of 0.4 milligrams per cubic metre as thoracic particulate mass (NIOSH, 1998).

Sources

  1. Deutsche Gesetzliche Unfallversicherung [DGUV]. (2012). Brand- und Explosionsschutz an Werkzeugmaschinen, DGUV Information 209-026, formerly BGI/GUV-I 719. April 2009, updated March 2012. https://publikationen.dguv.de/widgets/pdf/download/article/807
  2. Deutsche Gesetzliche Unfallversicherung [DGUV]. (2020). Brand an Werkzeugmaschinen: Was ist zu beachten?, Fachbereich AKTUELL FBHM-043. https://publikationen.dguv.de/widgets/pdf/download/article/3878
  3. Deutsche Gesetzliche Unfallversicherung [DGUV]. (2021). Brand- und Explosionsschutz an WZM, Fachbereich AKTUELL FBHM-032. https://publikationen.dguv.de/widgets/pdf/download/article/4330
  4. Gant, S. (2013). Generation of flammable mists from high flashpoint fluids: Literature review (Research Report RR980). Health and Safety Executive.
  5. Institut für Arbeitsschutz der DGUV [IFA]. (n.d.). Brand- und Explosionsgefahren, IFA-Praxishilfen Kühlschmierstoffe. Retrieved November 2026. https://dguv.de/ifa/praxishilfen/kuehlschmierstoffe/gefaehrdungsbeurteilung/brand-und-explosionsgefahren/index.jsp
  6. International Organization for Standardization [ISO]. (2017). ISO 2592:2017, Petroleum and related products: Determination of flash and fire points, Cleveland open cup method.
  7. International Organization for Standardization [ISO]. (2019). ISO 19353:2019, Safety of machinery: Fire prevention and fire protection. https://www.iso.org/standard/76473.html
  8. Korea Ministry of Government Legislation [MOLEG]. (n.d.). Enforcement Decree of the Safety Control of Dangerous Substances Act, Annex 1, Dangerous substances and designated quantities. National Law Information Center. Retrieved November 2026. https://www.law.go.kr
  9. Michalek, D. J., Hii, W. W.-S., Sun, J., Gunter, K. L., & Sutherland, J. W. (2003). Experimental and analytical efforts to characterize cutting fluid mist formation and behavior in machining. Applied Occupational and Environmental Hygiene, 18(11), 842–854. https://doi.org/10.1080/10473220390237368
  10. National Institute for Occupational Safety and Health [NIOSH]. (1998). Criteria for a recommended standard: Occupational exposure to metalworking fluids (DHHS (NIOSH) Publication No. 98-102).
  11. Occupational Safety and Health Administration [OSHA]. (n.d.). Metalworking fluids: Safety and health best practices manual. U.S. Department of Labor. Retrieved November 2026. https://www.osha.gov/metalworking-fluids/manual

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.