Jonghwan Moon
Product group
Equipment/Service Lubricants

Opening up the machine or changing the oil straight away is the usual response when wear metals jump in an oil analysis, but the figures on the report carry not only wear but also how the sample was taken and the other elements in the oil, so one number alone rarely identifies the cause. What actually lies behind the jump can be real wear progressing, a changed sampling point or time, additive elements read as wear, dust ingress or another oil mixed in, and sometimes two or more at once.

Background

The routine oil analysis report arrives, and the iron figure has jumped to several times the last result and is flagged in warning colour. The machine is running as usual, with no change in sound or temperature. Today, someone has to decide whether to stop and open it up, change the oil first, or wait for the next sample.

Missing real wear lets bearings or gears deteriorate further, leading to major failure and a long stoppage. Misreading the figures, on the other hand, means a sound machine is stripped down at a cost in maintenance and production time, and the next warning is trusted less. Hard contaminant particles increase wear of bearings, gears and seals and can lead to outright failure, so telling whether the figure is wear or contamination matters in its own right (Nikas, 2010).

Elemental analysis in oil analysis measures the metals and certain other elements in the oil element by element, reporting additive elements, wear metals and contaminants in one go (ASTM International, 2018). These figures are concentrations in the oil, so they depend not only on how much metal wear produced but also on how much oil was consumed and how much new oil was added in the meantime (Macián et al., 2003). That is why the trend of samples taken under the same conditions, rather than a single figure, is the basis for judgement, and a standard guide sets out how to derive alarm limits statistically from the distribution of a machine's own data (ASTM International, 2021).

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: check against the records whether this sample and the last were taken at the same point in the same way, how long the oil had been in service and how much had been topped up on the sampling day, and compare the results with an analysis of the same oil new, or with its technical data sheet, the TDS.

Hypothesis 1: real wear increase

After a rise in load or speed, when shaft alignment has drifted or vibration has grown, after a period when the oil ran low or was the wrong viscosity, or as bearings and gears near the end of their life, the figure may be telling the truth about wear. Take a single conveyor drive gearbox. The sample was taken from the same valve by the same person as always and the oil is unchanged, yet iron has risen sharply on this report and the vibration reading for the same month is also slightly up.

When contacting surfaces wear, metal fragments break off into the oil, and elemental analysis measures that metal as a concentration per element. But the analysis is calibrated with oil-soluble metals and does not capture large particles in full. Results by inductively coupled plasma analysis depend on particle size and come out low for particles larger than a few micrometres, and rotating disc electrode analysis detects particles up to about 10 micrometres (ASTM International, 2017, 2018). So once wear starts to shed larger fragments, the figure may rise by less than the wear itself. Large particles are examined separately by ferrography, which collects wear particles magnetically onto a glass slide for viewing under a microscope (Seifert & Westcott, 1972).

First take one more sample at the same point by the same method and see whether the figure repeats. If it does, match the combination of metals that rose together with the materials of the machine's parts to narrow down where they came from, and ask the laboratory for particle counting and ferrography as well. Viewing a ferrography slide under the microscope separates ferrous from non-ferrous particles, and the baseline picture of normal wear has to be set for each type of machine (ASTM International, 2024b). Put vibration, bearing temperature and noise records for the same period alongside.

If the second sample is also high and the particles look different from the normal baseline, shorten the sampling interval to follow the trend closely and look for the condition that drove the wear, such as alignment, load or lubrication. If vibration or temperature is rising with it, bring the inspection forward with maintenance, and when the parts are opened, record the damage alongside the analysis results as a reference for future decisions.

Hypothesis 2: changed sampling

If the sample that jumped was taken by someone else, at another point or at another time, suspect the sample first. This covers machines with no sampling valve, where oil is taken from the drain plug or the top of the tank, samples taken after a long standstill, and samples taken right after an oil change or a top-up. Suppose a sample normally drawn from a valve on the circulating line of a running gearbox was, in a week when the usual person was on leave, taken by someone else from the drain plug of the stopped machine. A thin layer of dark sediment lies at the bottom of that bottle.

A sample means something only if it represents the oil in the machine. In an operating system, samples are to be drawn from a sampler on a main line where the oil flows turbulently (ISO, 1992). Particles and sludge settle to the bottom of a stopped machine, so a sample from the drain tends to show more metal than usual. Guidance on sampling turbine lubricants likewise calls for representative, repeatable samples, and notes that taking samples at several points can help when the condition of individual components is wanted (ASTM International, 2024a). Timing shifts the figures too. Wear metal concentration is affected by oil consumption and fresh oil additions, so a sample right after a top-up can read low, and one taken after a long run without topping up can read high (Macián et al., 2003).

Lay out the sampling records and compare this sample with the last one line by line: who took it, at which point, whether the machine was running, how long after stopping if it was not, whether the standing oil in the sampling valve was flushed out first, and how many hours the oil had run and how much had been topped up by then. If anything differs, take a fresh sample the usual way and compare the two results.

When the sample turns out to be the cause, put the sampling procedure on a single sheet. Sample at the same point, in the same running state and in the same order, flush the standing oil from the valve and fill a clean new bottle, and tag each point so that whoever samples uses the same place. Record oil hours and top-up volume on the report, and trend a wear rate corrected with these maintenance records rather than the absolute concentration. In engine samples from an urban transport fleet, such a corrected wear rate reflected wear condition better than absolute concentrations (Tormos et al., 2004).

Hypothesis 3: additive read as wear

When the baseline shifts, as with the first analysis after a change to new oil, an oil sold under the same name but reformulated, or the first report from a new laboratory, look first at how the figures are being read. The same applies when there is a habit of reading every element on the report as wear. Think of the first report after switching to a new grade of oil. Zinc, phosphorus, calcium and silicon all show much larger figures than last time, and the person reviewing it marks this as a jump in wear metals across the board.

Additives are compounds containing metals, phosphorus or silicon, so in elemental analysis they appear as element-by-element figures just like wear metals. Calcium, barium, zinc, phosphorus and potassium are named among the common additive elements, and their concentrations can show how fast an additive is being used up or even a change in the top-up oil (Perkins et al., 1957). Silicone used as an antifoam also reads as silicon, typically at around 1 to 10 ppm (Noria Corporation, n.d.). Elemental analysis measures the amount of each element but does not say whether it came from wear particles or from additives, so when elements that were in the new oil all along go up, a change of oil is easily mistaken for wear.

Checking whether the elements that rose are also in the new oil sorts this out. Send a new-oil sample of the oil now in use to the same laboratory for a baseline, and set each element of the in-service sample against it. If only elements already abundant in the new oil have risen while the metals that make up the machine's parts are unchanged, the oil has changed, not the wear. Match the dates of any change of oil grade, supplier or batch with the report dates as well.

If the reading was the problem, send a new-oil baseline sample first whenever the oil changes, reset the baseline and mark that point on the trend chart. Agree with the laboratory that the report separates additive elements, wear metals and contaminants, and set alarm limits on wear metals and contaminants only. Elements such as silicon, which can come from both additives and contamination, are looked at together with the next hypothesis.

Hypothesis 4: dust ingress

Equipment near cement works, mines, foundries and building sites, breathers with no filter or a blocked one, shafts with damaged seals, and a habit of topping up with the cap off or from open containers are all routes for dust. In a windy spring, a gearbox beside a cement silo has a filler cap that no longer closes properly. On this report silicon and aluminium have risen sharply, and iron has followed them up.

Dust is mostly silica and alumina, so when it gets in, silicon and aluminium rise together. In practice, the two moving in step at a ratio of roughly 3.4 to 1 is taken as the signature of dirt, and when silicon rises alone, other sources are suspected: antifoam, silicone sealants, casting sand from new parts or coolant (Noria Corporation, n.d.). Hard particles that get in become trapped between contacting surfaces and cause abrasion, dents, flaking and in severe cases scuffing, increasing wear (Nikas, 2010). So when dust is the cause, the metals of those surfaces tend to follow silicon upwards.

Begin by checking whether silicon and aluminium rose together. If they did, go round the breather filter, the filler cap, grime and dust around the shaft seals, and the cleanliness of the top-up containers and funnels one by one. If only silicon rose, look in the records for new silicone sealant, newly fitted parts or a change of oil. Adding a particle count to the analysis lets the amount of dust entering be followed as a trend.

Once the route for dust is found, close it first. Fit filtered breathers, replace damaged seals, top up from dedicated closed containers and, where possible, through a filter. Reduce particles already inside by filtering or changing the oil, then analyse again to see whether silicon and the wear metals come down together. The effect of air and lubricant filtration on machine life has long been a subject of research (Nikas, 2010).

Hypothesis 5: another oil mixed in

Set up this hypothesis when the top-up oil ran out and another oil nearby was used, when the supplier changed, when a lot of old oil was left behind at an oil change, or when funnels and top-up cans are shared across several oils. Say that on a night shift the gear oil for topping up ran out and a can of hydraulic oil from the next machine was poured in, and the event never made it into the log. On the next analysis several element figures suddenly look different, and viscosity is outside its usual range too.

Each oil has its own additive formulation, so when another oil gets in, the make-up of additive elements shifts all at once. It has long been reported that additive element concentrations can reveal a change in the brand of top-up oil (Perkins et al., 1957). If the oil mixed in was itself used oil, the wear metals and contaminant particles already in it come along too, and even a fresh oil addition changes the concentrations (Macián et al., 2003). And if the oil that got in lacks the viscosity or additives the machine needs, the result may go beyond a misleading figure and turn into real wear.

Comparing the pattern of additive elements is the key. Set the new-oil baselines of the current oil and the suspect oil side by side, and see whether elements such as zinc, phosphorus and calcium in the in-service sample have shifted towards a point between the two. Measure viscosity to see whether it has left its grade, and check the top-up records and drum labels and ask the shift crew what went in. Whether used oil got in can be narrowed down by where the top-up can came from.

If another oil appears to have got in, confirm with the supplier whether the two can be used together, and change the oil if the amount mixed is large or the oils are incompatible. After the change, take a new baseline sample and restart the trend. Keep separate top-up containers and funnels for each oil, marked by label or colour, and have every top-up logged with date, quantity and oil name.

Finding the cause

Faced with a sudden jump, the first thing to do is take one more sample by the same method. Sampling records, oil and top-up records and the new-oil baseline are already to hand, so sampling, reading of elements and mixed oil can be ruled out first, from the office, without stopping the machine. Routes for dust take one walk round the machine. Real wear is examined in depth once these are cleared.

Next, see which elements moved together. If only elements that are abundant in the new oil went up, the cause lies with additives read as wear or with another oil mixed in, and if viscosity changed as well, give more weight to mixed oil. Silicon and aluminium rising together with wear metals following point to dust; a figure that falls on resampling points to how the sample was taken. If repeat sampling by the same method still shows only the metals of the machine's parts high, the cause lies with real wear.

If that still does not settle it, compare by changing one thing at a time. On the same day, take a sample from the valve while running and one from the drain after stopping, analyse a new-oil baseline at the same laboratory alongside, and after fitting a filtered breather follow the silicon trend for one cycle. Only by changing one thing at a time is it clear which change moved the figure. Revisit the alarm limits statistically as the machine's own data builds up (ASTM International, 2021).

The final check is whether the figures and the machine's condition tell the same story. Do not conclude from elemental analysis alone; put particle counts, ferrography, vibration and temperature alongside. A review of lubricant condition monitoring research likewise treats sampling and testing as the starting point of interpretation, and brings together methods that judge several kinds of data jointly with statistics and models (Wakiru et al., 2019).

The hypotheses can overlap. Dust raises silicon and brings real wear with it, and a mixed oil changes the elements and can at the same time worsen lubrication and increase wear. In such cases, close the entry routes first, dust and wrong oil, put sampling right, and then look at the wear trend again, because while what enters the oil keeps changing, the wear metal trend cannot be relied on for judgement.

Limits and cautions

Element alarm limits and suitable sampling intervals differ by machine type, component materials, oil and operating conditions, so numeric decisions follow the equipment maker's guidance, the oil's TDS and the laboratory's criteria. Statistically derived limits do not replace limits set and validated by the equipment maker either (ASTM International, 2021). Where analysis alone cannot justify stripping a machine or stopping it, decide together with the maintenance lead, using other diagnostics such as vibration and thermography.

Safety matters too. When sampling a running machine, use only sampling valves well away from moving parts, take care with hot oil and pressurised lines, and wear eye protection and gloves. Sample from drains or tanks only with the machine stopped and locked out. Handle the oil according to the product's safety data sheet, the SDS, and collect leftover samples and rags in the designated container.

Sources

  1. ASTM International. (2017). ASTM D6595-17, Standard test method for determination of wear metals and contaminants in used lubricating oils or used hydraulic fluids by rotating disc electrode atomic emission spectrometry. https://store.astm.org/d6595-17.html
  2. ASTM International. (2018). ASTM D5185-18, Standard test method for multielement determination of used and unused lubricating oils and base oils by inductively coupled plasma atomic emission spectrometry (ICP-AES). https://store.astm.org/d5185-18.html
  3. ASTM International. (2021). ASTM D7720-21, Standard guide for statistically evaluating measurand alarm limits when using oil analysis to monitor equipment and oil for fitness and contamination. https://store.astm.org/d7720-21.html
  4. ASTM International. (2024a). ASTM D8112-24, Standard guide for obtaining in-service samples of turbine operation related lubricating fluid. https://store.astm.org/d8112-24.html
  5. ASTM International. (2024b). ASTM D7690-24, Standard practice for microscopic characterization of particles from in-service lubricants by analytical ferrography. https://store.astm.org/d7690-24.html
  6. International Organization for Standardization [ISO]. (1992). ISO 4021:1992, Hydraulic fluid power: Particulate contamination analysis: Extraction of fluid samples from lines of an operating system. https://www.iso.org/standard/9706.html
  7. Macián, V., Tormos, B., Olmeda, P., & Montoro, L. (2003). Analytical approach to wear rate determination for internal combustion engine condition monitoring based on oil analysis. Tribology International, 36(10), 771–776. https://doi.org/10.1016/S0301-679X(03)00060-4
  8. Nikas, G. K. (2010). A state-of-the-art review on the effects of particulate contamination and related topics in machine-element contacts. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 224(5), 453–479. https://doi.org/10.1243/13506501JET752
  9. Noria Corporation. (n.d.). Sources of silicon in oil. Machinery Lubrication. Retrieved November 2026. https://www.machinerylubrication.com/Articles/Print/28673?id=28673
  10. Perkins, W. D., Miller, J. R., & Moser, J. H. (1957). The evaluation of a direct emission spectrographic method for the analysis of used lubricating oils (STP46907S, pp. 132–139). ASTM International. https://doi.org/10.1520/STP46907S
  11. Seifert, W. W., & Westcott, V. C. (1972). A method for the study of wear particles in lubricating oil. Wear, 21(1), 27–42. https://doi.org/10.1016/0043-1648(72)90247-5
  12. Tormos, B., Macián, V., Olmeda, P., & Montoro, L. (2004). Wear rate determination for IC engine condition monitoring: Results obtained in an urban transport fleet (SAE Technical Paper 2004-01-1963). SAE International. https://doi.org/10.4271/2004-01-1963
  13. Wakiru, J. M., Pintelon, L., Muchiri, P. N., & Chemweno, P. K. (2019). A review on lubricant condition monitoring information analysis for maintenance decision support. Mechanical Systems and Signal Processing, 118, 108–132. https://doi.org/10.1016/j.ymssp.2018.08.039

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.