When oil shows in the sight glass, the usual response is to rule out lubrication and suspect bearing quality or assembly, but oil in the housing is not the same as oil reaching the rolling contacts clean, in the right amount and at the right viscosity. What actually lies behind the failures can be a running oil level unlike the static one, a constant level oiler set wrong, a slipping oil ring, water in the oil or a viscosity that does not suit the operating temperature, and sometimes two or more at once.

Background

The sight glass on a pump bearing housing shows oil at the mark, and the constant level oiler bottle still holds oil. Yet the bearing grew noisy, ran hotter and finally had to be replaced, and the raceways of the removed bearing are flaked or discoloured. A new bearing and fresh oil go in, and a few months later the same position fails again. The question on the floor is why this happens when there was clearly oil in the housing.

A bearing that seizes stops the pump and the line without warning, and as damage spreads, the shaft, seals and housing suffer too. Replacing only the bearing without knowing why repeats the replacement cost and the downtime, and while each failure is put down to bearing quality or assembly, the real cause stays in place.

In oil-bath lubrication, the rotating bearing parts pick up oil and spread it through the bearing, and the oil flows back to the sump (SKF, 2011). For the bearing to survive, that oil has to build a film of sufficient thickness between rolling elements and raceways; how ample the film is shows in the viscosity ratio, the actual viscosity at operating temperature divided by the minimum viscosity that bearing needs, and bearing life calculations take in this ratio along with how contaminated the oil is (ISO, 2007). So oil in the housing is not enough on its own: whether it reaches the bearing at the right height, whether it is clean, and whether it is thick enough at operating temperature all have to be looked at.

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: keep the removed bearing and the oil from the bottom of the housing, note the oil level at standstill and while running, the oiler height and the housing and oil temperatures, and compare them with the equipment manual and the oil's technical data sheet, the TDS.

Hypothesis 1: wrong running level

Look at this hypothesis where the level is only ever set with the machine stopped, on high-speed machines where oil splashes and swirls heavily inside the housing, and on equipment where nobody knows which condition the sight glass mark refers to. Say that on a maintenance day the stopped pump is filled to the mark while watching the sight glass. Once the pump runs again, the oil in the sight glass drops below the mark and surges, and after a few weeks like this the bearing temperature creeps up.

Oil is dragged along by rotating parts, splashes around the housing and runs down its walls, so while running the oil pooled at the bottom sits lower than at standstill. When the machine stops, the splashed oil returns and the level rises (SKF, n.d.). A bearing maker's maintenance guidance says to set the oil-bath level at the middle of the lowest rolling element in a static condition, and warns that in housings with oil pick-up rings the level may drop during operation. The same guidance explains that too much oil also causes excessive churning and raises temperature (SKF, 2011). So a level set to the mark at standstill may barely reach the rolling elements, or miss them, while running, and a generous fill may thin the oil with churning heat. Either way, the sight glass shows oil.

The check is to read the same machine's level twice. Read and mark the level in the sight glass at standstill and again once running has settled, and compare where the running level falls on the lowest rolling element with the housing drawing or the equipment manual. Check that the sight glass truly connects with the inside of the housing and that the oil return holes are not blocked. Logging bearing temperature while running lets you compare which way the temperature moves when the level is changed.

If the level is the cause, first make clear whether the reference is the static or the running level, and mark that reference on the sight glass. On machines referenced to the static level, top up only when stopped; on machines that must be set while running, mark the running height separately so operators are not confused. A sight glass on every housing is a quick way to check that the level is right (SKF, 2011). If churning heat is suspected, lower the level within the reference range and watch the temperature.

Hypothesis 2: oiler set wrong

The setting is pumps and fans with a bottle-type constant level oiler beside the housing. It applies particularly when an oiler is newly fitted or changed to another model, when its bracket height has been altered, or when the housing vent is blocked or new seals have made the housing nearly airtight. Picture an oiler bottle with plenty of oil, while a look through the sight glass shows the level inside the housing well below the bearing. The oiler has not dropped for weeks.

A constant level oiler is made of two connected chambers. The lower chamber is joined to the housing, shares its oil level and is open to the outside air through a vent. The upper chamber is an airtight store, so air enters it, and the same amount of oil runs down, only when the level in the lower chamber drops below the set height and exposes the end of its neck. What the oiler holds, then, is the height at which the oiler itself sits, and the reference level is taken as the running level. An oiler cannot correct a level that is too high, and if the connecting tube is kinked or blocked, oil cannot flow to the housing (SKF, n.d.). Pressure in the housing also deceives the oiler. A bearing maker's maintenance guidance warns that a housing not vented properly builds back pressure, which can make automatic lubricators malfunction (SKF, 2011). As the housing warms and its internal pressure rises, the housing level is pushed down while the level on the oiler side stays put or even rises, and the oiler may send no oil.

Look at the oiler and the housing level side by side. While running, see whether the level in the oiler's lower chamber and in the housing sight glass are at the same height; if not, check the housing vent, seals and connecting tube in turn. Measure the height of the oiler bracket and see whether it matches the running level recommended by the equipment manual or the bearing maker, and check whether there are top-up records since the oiler was fitted and whether oil in the upper chamber actually goes down. If the level comes up when a housing plug is briefly loosened, the housing was under pressure.

Once it points to the oiler, correct height and pressure first. Reset the bracket to the running level reference and refit the connecting tube short and free of kinks. Clear the housing vent or fit a suitable breather so oiler and housing share the same pressure, and when changing seals, review how the housing pressure will change. When replacing an oiler, confirm it is a type with the same reference height as before, and log top-up dates and amounts so an oiler whose oil never drops is found early.

Hypothesis 3: slipping oil ring

Look at this in housings using an oil ring, a ring hung on the shaft that lifts oil and delivers it to the bearing. This arrangement suits horizontal shafts only (SKF, 2011), and some designs place the bearing above the oil level, relying on the ring alone for oil. Pay closer attention on machines started with cold oil in winter, machines installed with the shaft out of level, and rings that have not been replaced for a long time. Through an inspection plug, the shaft turns fast while the ring turns slowly, hesitates, or leans to one side and wobbles, and yellow metal particles glint in the oil at the bottom of the housing.

An oil ring hangs loosely on the shaft and turns by friction and the drag of the oil; the part dipped in the sump comes up coated with oil and passes it to the shaft and the bearing. Ring speed and oil delivery have been studied for a long time (Lemmon & Booser, 1960). One study of ring lubricators for rolling bearings named immersion depth, oil viscosity, shaft speed, ring dimensions and cross-section, and the way the ring is guided sideways as design variables that govern oil delivery and oil life. In the same study's tests, oil delivery differed markedly with the type of axial ring guidance, ring wear contaminated the oil, and how much the ring wobbled at start-up depended strongly on the friction between ring and shaft (Müller & Tremmel, 2016). When the ring lags behind the shaft or hesitates, less oil reaches the bearing even with a full sump.

The ring has to be seen. Through an inspection plug or a clear cover, see whether the ring turns evenly while running, without wobbling or hesitating, and compare just after start-up with after the oil has warmed. When stopped, take the ring out and look at its roundness, wear marks and chips, and check that the shaft groove or guide parts it runs on are not rough. Check with a spirit level that the shaft is horizontal, and compare the running level with the manual to see that it wets the ring as designed. Metal particles in the bottom oil are a clue to ring wear, so keep a sample.

Replace a worn or distorted ring and dress the shaft groove and guide parts it runs on. Correct the installation if the shaft is out of level, and set the oil level so the ring is immersed to its design depth. If the ring hesitates only on winter start-ups, warm the oil before starting or settle on a viscosity for that temperature with the equipment maker. If ring wear particles have appeared, change the oil as well so they do not reach the bearing.

Hypothesis 4: water in the oil

This covers food plants that wash down floors with water, equipment surrounded by steam and condensate, pumps and cooling tower fans outdoors, and standby machines that run after long idle periods. The same goes for housings that draw in humid air each time they cool at night after warming by day. When a standby pump that stood for over a month makes noise soon after it is started, the outer ring raceway of the removed bearing often shows greyish black streaks spaced at the same pitch as the rolling elements. The oil at the bottom of the housing is milky.

Water damages bearings in two ways. One is corrosion. When water gets in, the lubricant loses its ability to protect steel surfaces, so deep rust forms easily during standstill, and water drawn by capillary action beside the rolling element contacts leaves greyish black streaks at the rolling element pitch. Bearing damage classification calls this moisture corrosion (SKF, 2011; ISO, 2017). The other is fatigue. In a study that tested full-scale tapered roller bearings in oil containing 25, 100 and 400 ppm of water, fatigue life correlated clearly with water content, and the harm done by water at these levels was plainly shown (Cantley, 1977). In rolling contact tests with balls, 0.01% water increased fatigue failures on the balls and also increased wear in rolling contact (Schatzberg & Felsen, 1969).

Water is relatively easy to confirm. From an oil bath, let a little oil run out of the drain first, then catch the sample in a clean container and seal it at once. Put a drop of the shaken sample on a hot plate at about 130 °C: bubbles mean free water, and audible crackling means the water is likely above 2,000 ppm. The test does not detect dissolved water, so use it only as a guide (SKF, 2011). For a figure, measure water by Karl Fischer titration (ASTM International, 2020). Look also at rust and streaks on the removed bearing, rust inside the housing and around the vent, and the condition of the seals.

Once water is confirmed, block its way in first. Keep washdown jets off the housing seals, replace worn seals, and where the housing breathes in humid air, consider a breather with desiccant. Change the oil and flush water and sludge from the bottom of the housing. A bearing maker's guidance says to keep water below 200 ppm in oil analysis (SKF, 2011). Run long-idle standby machines at regular intervals, and drain water from the bottom before starting them. Bear in mind too that in engine oil tests less water could stay dissolved at lower temperatures, so where a housing cools down, water that was dissolved can separate and collect at the bottom (Al Sheikh Omar et al., 2024).

Hypothesis 5: wrong viscosity

Suspect this hypothesis when a viscosity grade other than the one in the equipment manual has gone in, in plants that run many machines on one or two oils, on machines whose housing temperature rises sharply in summer, and after a change in speed or load. Call to mind a plant that standardised all its bearing oil on one grade for easier purchasing, after which bearings on a few pumps failed one after another in midsummer. The raceways of the failed bearings have lost their sheen and worn rough, and the housings are too hot to keep a hand on.

An oil's viscosity grade is set by its kinematic viscosity at 40 °C (ISO, 1992), but what the bearing actually uses is the viscosity at operating temperature. Each bearing has a minimum viscosity set by its mean diameter and speed, and the viscosity ratio, the operating viscosity divided by that minimum, is suitably between 1 and 4 in general. Low viscosity means low friction but a thin film, and high viscosity a thick film but more friction and a higher operating temperature, so a balance is needed (SKF, 2011). In the bearing life calculation too, the lower the viscosity ratio, the smaller the life modification factor and the shorter the calculated life (ISO, 2007). When the operating temperature is above 40 °C, the same oil is thinner by that much, so the actual viscosity in the housing falls below the grade number.

Match temperature and viscosity in numbers. Once running has settled, measure the housing surface or oil temperature, find the minimum viscosity the bearing needs from its mean diameter and speed, estimate the viscosity of the oil in use at that temperature from the 40 °C and 100 °C values on its TDS, and work out the viscosity ratio. Measure the viscosity of the used oil against new oil, and if it is more than 10% off the baseline, look for why it thinned or thickened (SKF, 2011). Check the purchase and top-up records too, to confirm the oil really is the specified grade.

If the viscosity ratio is out of the suitable range, whether too low or too high, choose a grade again so it falls within that range at operating temperature, and where viscosity is short, look at whether the temperature itself can come down. Bring the level within the reference to reduce churning, and for machines that run hot, add cooling or switch to circulating oil. If the whole plant was standardised on one grade, make exceptions for machines with different temperatures and speeds, and when changing, confirm with the supplier that the new oil can mix with the old.

Finding the cause

The five hypotheses need not be searched all at once. Running and static levels, the difference between oiler and housing levels, and how the ring turns can be seen in a few minutes without stopping the machine. The hot plate test and temperature readings can be done on the spot too. Exact figures for water and viscosity, and analysis of the damaged bearing surfaces, need samples sent away, so they come after.

The removed bearing points a direction. Greyish black streaks at the rolling element pitch, or rust, call for looking at water first. Discoloured raceways and a hot housing call for considering both too little oil reaching the bearing and too much oil being churned, narrowed down through the running level, the oiler and the ring. Metal particles in the bottom oil the same colour as the ring suggest a worn oil ring, and failures concentrated in summer or at high speed suggest viscosity.

If that still does not settle it, run control trials. Of two machines of the same type, correct the level or oiler height on just one and compare bearing temperatures, or change only the vent and see whether the gap between oiler and housing levels disappears. Changing the oil on a suspect machine and tracking water and viscosity for a period also works. Change only one thing at a time, or there is no telling what worked.

The final check is the next bearing. After the cause is corrected, see on the same recording basis whether bearing temperature settles while running, whether water and viscosity stay within limits in oil analysis, and whether the replacement interval lengthens. When the next bearing removed shows normal wear, the job is done.

The hypotheses can overlap. When a warming housing builds pressure, the oiler stops feeding and the running level drops further, and as it cools it breathes in humid air and water gets in. That water mixes into the oil and changes its viscosity, and a change in viscosity changes how much oil the ring lifts. In such cases, put venting and level right first, change the oil, and then measure water and viscosity again, because while level and pressure are unsettled, the effect of changing water or viscosity cannot be compared fairly.

Limits and cautions

Reference oil level, oiler height, ring immersion depth, suitable viscosity grade and water limits differ by bearing, housing and machine, so numeric decisions follow the equipment manual, the bearing maker and the oil's TDS. A final verdict on the cause of bearing damage needs analysis of the damaged surfaces, so if the same damage keeps recurring or the machine is critical, leave it to the bearing maker or an analysis laboratory. Causes outside lubrication, such as load, alignment and fits, can also produce damage, so if failures continue after lubrication is put right, look there.

Safety matters too. When watching the running level and the ring, keep hands and clothing clear of the turning shaft and coupling, and when loosening plugs or taking samples, beware of hot oil and housing pressure. Take out rings or refit oilers only after the machine is stopped and locked out, and when handling oil, wear gloves and eye protection as the product's safety data sheet, the SDS, directs.

Sources

  1. Al Sheikh Omar, A., Motamen Salehi, F., Farooq, U., & Morina, A. (2024). Additives depletion by water contamination and its influences on engine oil performance. Tribology Letters, 72, 74. https://doi.org/10.1007/s11249-024-01876-y
  2. ASTM International. (2020). ASTM D6304-20, Standard test method for determination of water in petroleum products, lubricating oils, and additives by coulometric Karl Fischer titration. https://store.astm.org/d6304-20.html
  3. Cantley, R. E. (1977). The effect of water in lubricating oil on bearing fatigue life. ASLE Transactions, 20(3), 244–248. https://doi.org/10.1080/05698197708982838
  4. International Organization for Standardization [ISO]. (1992). ISO 3448:1992, Industrial liquid lubricants — ISO viscosity classification.
  5. International Organization for Standardization [ISO]. (2007). ISO 281:2007, Rolling bearings — Dynamic load ratings and rating life.
  6. International Organization for Standardization [ISO]. (2017). ISO 15243:2017, Rolling bearings — Damage and failures — Terms, characteristics and causes.
  7. Lemmon, D. C., & Booser, E. R. (1960). Bearing oil-ring performance. Journal of Basic Engineering, 82(2), 327–334. https://doi.org/10.1115/1.3662590
  8. Müller, M., & Tremmel, S. (2016). Design criteria for oil ring lubricators to improve maintainability of rolling bearings [Conference presentation abstract]. STLE Annual Meeting & Exhibition. https://www.stle.org/images/pdf/STLE_ORG/AM2016%20Presentations/Rolling%20Element%20Bearings/STLE2016_Rolling%20Element%20Bearings%20VI_Session%208D_M.%20Muller_Design%20Criteria%20for%20Oil%20Ring%20Lubricators.pdf
  9. Schatzberg, P., & Felsen, I. M. (1969). Influence of water on fatigue-failure location and surface alteration during rolling-contact lubrication. Journal of Lubrication Technology, 91(2), 301–307. https://doi.org/10.1115/1.3554919
  10. SKF. (2011). SKF bearing maintenance handbook (PUB SR/P7 10001/1 EN). SKF Group. https://web.mit.edu/course/2/2.70/Reading%20Materials/SKF-bearing-maintenance-handbook.pdf
  11. SKF. (n.d.). SKF oil levellers LAHD 500 and LAHD 1000: Instructions for use. Retrieved November 2026. https://res.cloudinary.com/iwh/image/upload/q_auto,g_center/assets/1/26/SKF_LAHD_Series_Oil_Leveller_Instructions_for_use.pdf

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.