Applying a thinner coat next time is the usual response to sagging, but that easily falls short of the specified film thickness and leaves whatever drove the flow in place. What actually pulls paint down a vertical surface can be too thick a film, over-thinning, low temperature, too little thixotropy or slow drying, and sometimes two or more at once.

Background

A few minutes after paint is sprayed onto a vertical wall or the side of a tank, curtain-like ripples hang across the lower part and teardrop runs form under bolt holes and edges. Runs that cure in place have to be sanded off and repainted, so labour and paint are spent twice. Sagging also makes the film uneven, thin at the top and piled up thick along the lower edge. The piled-up areas take a long time to dry through, and the thinned areas can fall short of the specified dry film thickness and fail to protect the substrate properly (USACE, 1995).

A wet film on a vertical surface is always pulled downwards by gravity. The stress on the film where it meets the substrate grows with the paint's density and the wet film thickness, and how far the film flows is set by the viscosity at that stress (Eley & Schwartz, 2002). For a liquid of constant viscosity, the speed at which the film surface moves down rises with the square of the film thickness and falls as viscosity rises. In real paint, sagging happens when the viscosity does not rise fast enough after application to stop the flow, and viscosity can also vary with depth while solvent diffuses through the film and evaporates (Issa et al., 2022).

So sagging is a race against time. Thickness sets the force pulling the film down, and what stops the flow is the viscosity that rises as solvent leaves, as structure broken down by stirring rebuilds and as cure begins. Anything that makes the film thicker, lowers the viscosity from the start or slows its rise shows up as the same symptom.

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: measure the wet film thickness next to the sag straight away, log the amount of thinner added and the air and surface temperatures that day, and compare them with the recommended film thickness, thinning ratio and application temperature in the paint's technical data sheet, the TDS.

Hypothesis 1: too thick a film

A film easily ends up too thick when the specified dry film thickness is meant to go on in a single coat. It also thickens locally when the spray gun is held too close or moved too slowly, when passes overlap too much, and when corners and welds get an extra pass. Picture a day when the schedule is tight and a film meant for two coats goes onto a tall tank wall in one. A thick horizontal ripple forms at every overlap of the passes sprayed from the top down, and paint pools into drops along the bottom edge.

Why thickness matters so much shows in the flow calculation. The stress pushing the film at the substrate is proportional to thickness, and at the same viscosity the amount that flows is proportional to the cube of thickness, so doubling the film thickness multiplies the flow eightfold. Where the substrate shape is uneven, such as at edges and around holes, pressure differences created by surface tension pile paint up there, and gravity acting on that build-up leaves a run (Eley & Schwartz, 2002). That is why the same paint sags first at overlaps and under edges rather than on flat areas. The thickness at which flow begins differs from paint to paint, so laboratories draw several thicknesses at once with an applicator cut with notches of different depths, stand the panel upright and see from which thickness it runs (ASTM International, 2018).

Right after application, measure the wet film thickness with a comb-type wet film gauge at sagged and unsagged spots. Press the gauge into the wet film at right angles and lift it off: the two ends and some of the steps come up wet, and the depth of the last wet step is the wet film thickness. That reading means something only against the target wet thickness, the TDS dry film thickness divided by the volume solids fraction, and accuracy drops as solvent evaporates, so measure as soon as the paint is on (USACE, 1995). Once cured, measure the dry film thickness at the top and along the lower edge and compare them.

When thickness turns out to be the cause, the answer is to put on less at a time. Split the specified dry film thickness into two or three coats, each within the maximum per coat that the TDS allows, and keep to the recoat interval. Hold the gun distance, travel speed and overlap steady, and stripe edges and welds thinly by brush first. When painters check with a wet film gauge as they go, overbuilt areas can be caught before the paint sets.

Hypothesis 2: over-thinned paint

When paint is too stiff to spray, painters are tempted to add more thinner. Paint kept in a cold store becomes very viscous, and thinner is then sometimes added in excess to make it sprayable (USACE, 1995). The same happens when mixing goes by eye with no rule, when a different person mixes each can, and when an unspecified thinner is used. Suppose a can brought in from an outdoor store one morning is so stiff the stirrer barely goes in, and the painter pours in more thinner a few times and stirs before starting to spray. The surfaces painted that day glisten evenly all over, then sag across wide areas at once, starting right after application.

Thinner exists to lower viscosity, so the more of it goes in, the more easily the paint flows. Paint of too low a viscosity produces runs, sags, drips and similar defects. Thinning also makes the film thicker by another route. Adding thinner increases the total volume with no increase in solids, so the volume solids fraction falls and a heavier wet film is needed to reach the same dry film thickness. Lower viscosity and a thicker wet film then drive the flow together. Conversely, if the wet film goes on as usual, the dry film comes out short and protects the substrate poorly (USACE, 1995).

Start with the mixing records. Compare the type and amount of thinner added to each can with the maximum thinning ratio in the TDS, and if there is no record, time how long a set volume of the remaining mixed paint takes to drain through the orifice of an efflux cup such as a Ford or Zahn cup, against the same paint unthinned (USACE, 1995). A clearly shorter drain time means over-thinning. Check as well whether the target wet film thickness was recalculated for the thinning ratio before painting.

If thinning was excessive, add only the thinner the paint manufacturer recommends, and no more than the amount it recommends or volatile organic compound rules allow (DoD, 2021). Rather than thinning stiff paint, it is better to warm the paint and substrate to the TDS application temperature, and in cold seasons paint is also heated and hot-sprayed to avoid extra thinner (USACE, 1995). Measure the thinning ratio with a graduated cup and record it for each can.

Hypothesis 3: too cold

Consider this hypothesis in unheated winter workshops, on steelwork chilled overnight, and when parts stored outdoors are brought in and painted straight away. Heavy steel warms more slowly than air, so the room temperature the painter feels can differ from the temperature of the substrate the paint lands on. A typical scene: on a midwinter morning a heavy plate structure is brought in from the yard, and two-part epoxy goes on soon after the heaters are switched on. The surface looked fine while being painted, yet by lunchtime it is still wet enough to come off on a finger, and long marks of slow sagging have formed in the meantime.

Low temperature slows everything that stops the flow. Solvent evaporates more slowly when cold, and with waterborne paint, cold and damp weather slow both water evaporation and the coalescence of the film. The cure of reactive paints depends on temperature too: many epoxies cannot be applied when the steel is below 10 °C, and few paints can be applied safely at or near 0 °C. In a heated workshop the air warms faster than the steel, so dew can also form on the cold steel surface (USACE, 1995). Since sagging happens when the viscosity does not rise quickly after application, the film can keep flowing for as long as the rise is delayed (Issa et al., 2022). Cold paint itself turns stiff, and that very stiffness can lead painters to add more thinner, which brings in the thinning problem.

Temperature reveals itself as soon as it is measured. Before and during the work, measure air temperature, relative humidity and substrate surface temperature, with the surface thermometer placed directly on the area to be painted. Compare the substrate temperature with the TDS minimum, and check whether it is at least 3 °C above the dew point, as specifications commonly require (USACE, 1995). Measure the temperature of the paint in the can as well, and match it against the mixing records to see whether cold paint was thinned to make it usable. Painting the same paint at the same thickness on a warm panel and a cold panel and standing them upright gives a direct comparison of how much each sags.

If low temperature is behind it, the first step is to bring the substrate and paint within the TDS application temperature before painting. Move parts into the workshop the day before so the steel can warm up, and keep the paint somewhere warm so it reaches a sprayable viscosity without thinner. Hold the temperature after painting until cure is under way, and agree with the supplier whether a low-temperature-cure paint or a seasonal thinner is needed.

Hypothesis 4: too little thixotropy

Suspect the paint's flow behaviour when a high-build paint, made to go on thick, sags more readily than usual, or when only certain lots of the same product sag. Paint stored so long that a hard layer has formed at the bottom of the can, and paint into which additives or thinners meant for other uses were mixed on site, also belong here. Sometimes the same painter, with the same gun on the same kind of surface, sees sagging at normal thickness from the day a new lot arrives, while areas painted from the previous lot are fine.

Thixotropy is the property of losing viscosity when stirred and regaining it over time at rest (Barnes, 1997; Mewis & Wagner, 2009). In paint, thixotropes such as castor oil derivatives, clays and fumed silica provide it. Shear, the sliding force applied in mixing and spraying, breaks the thixotropic structure down quickly so the paint sprays as if it were thin, and once on the surface the structure recovers, building film and resisting sag (USACE, 1995). If the structure recovers more slowly than the paint flows, or recovers to too low a viscosity, the film runs in the meantime.

Resisting sag calls for high viscosity and levelling calls for flow, so the two demands pull against each other. A study of high-solids paints calculated, and confirmed by experiment, that to resist sag and still spray well a paint must thin as shear increases, with a viscosity of about 25 poise at a shear rate of 1 s⁻¹ at the temperature of use (Wu, 1978a). The same author reported that balancing levelling as well shifts that viscosity to about 50 poise (Wu, 1978b). Sag control agents are additives used to strike this balance, and test methods for studying their effect have also been developed (Bosma et al., 2006).

This hypothesis is settled in the laboratory rather than on the floor. Draw the problem lot and a good lot under the same conditions with a notched applicator, stand the panels upright and compare the thickness at which each starts to run, or spray onto panels held vertical and compare the sagging (ASTM International, 2018; ISO, 2003). With a rotational viscometer, measure for both lots how viscosity recovers over time right after vigorous shearing. Check the records too for a hard layer at the bottom of the can and for anything added on site.

Once the problem lot is pinned down, stop using it and report it to the supplier with the test results. Before use, mix thoroughly by the method and time the TDS sets so that any bottom layer is worked back in, and add no unspecified additives or thinners. For surfaces that genuinely need a thick film, review with the supplier the use of a product designed as high-build from the outset.

Hypothesis 5: slow drying

A film stays wet for a long time in confined spaces with no airflow, in booths with weak extraction, when a slow summer thinner stays in use after the season changes, and with waterborne paint applied on a humid day. Imagine painting the walls inside a tank, where the air stands still. The same paint that soon stopped coming off on the hand on the outside still glistens on the inner walls long afterwards, and the runs on them slowly lengthen in the meantime.

Solvent loss after application falls into two regimes. In one, drying is governed by how fast solvent evaporates from the surface, that is, by its volatility; in the other, by how fast solvent inside the film diffuses out to the surface (Waggoner & Blum, 1989). As solvent leaves, structure and elasticity develop in the film that let it resist gravity, so when solvent leaves slowly, viscosity rises slowly and the film can sag in the meantime (Issa et al., 2022). Solvent must evaporate fast enough to prevent runs and sags, but too fast causes other defects such as solvent pops, loss of gloss and dry spray, which is why paints use a blend of fast and slow solvents (USACE, 1995).

First see which thinner was used. Check that the thinner named on the can matches the product and seasonal grade the TDS recommends, and in a booth check extraction airflow and filter condition; in a confined space, confirm the ventilation actually ran. Paint two panels with the same paint at the same thickness, put one where air moves freely and the other at the problem spot, and time how long each takes to stop marking a finger; the difference in drying conditions then shows as a number.

Where drying looks slow, restore airflow first. Change booth filters and set the extraction, and in confined spaces keep ventilation going throughout painting and drying. Choose a thinner grade for the season and working temperature from within the TDS range, and for waterborne paint avoid humid days or dehumidify. Ventilation is also a safety measure that stops solvent vapour building up.

Finding the cause

Five hypotheses need not take long if they are taken in order. Wet film thickness, thinner amount and temperature can be measured at the workpiece in minutes and compared using only the mixing records and the TDS, so rule them out first. The flow behaviour of the paint lot and the drying conditions need panels and tests, so they come next.

The next clues are the shape and timing of the sag. If it sags only where paint has built up, at overlaps, under edges and around holes, look at film thickness first. If the whole surface sags evenly right after application, the viscosity was low from the start, which points to over-thinning or too little thixotropy. If the film holds while being applied and then sags slowly much later, or sags only where air stands still or on cold parts, suspect what delays the viscosity rise: low temperature or slow drying.

If that does not settle it, run control trials that change one thing at a time. Paint the same paint unthinned, apply the same thickness in two coats, paint on a warmed panel and a cold one, and switch to another lot. The notched applicator test suits lot-to-lot comparison, but in one study paints it rated as identical still differed in sag on a vertical surface when the speed of surface flow was measured directly (Lade et al., 2015). So even when laboratory ratings match, also test by painting real surfaces standing upright.

The final check is whether the sagging has gone while the specified dry film thickness is actually reached. If the runs have gone but the film is thinner, the cause may not have been fixed, only less paint applied, so once cured, measure film thickness at the top, the bottom and the edges and confirm it falls evenly within range.

The hypotheses can overlap. Paint kept somewhere cold turns stiff and gets extra thinner (USACE, 1995), thinned paint needs a heavier wet film to reach the same dry film thickness, and on a cold substrate the viscosity of that film rises late. In such cases correct the temperature first, then bring the thinning ratio back within the TDS, and finally look at the thickness put on per coat, because while temperature is unsettled the effect of changing thinning or thickness cannot be compared fairly.

Limits and cautions

Maximum thickness per coat, thinning ratio, minimum application temperature and dew point conditions differ by paint, so numeric decisions follow the product's TDS and the job specification. Whether to fix a sagged film before it sets or to sand and repaint after cure also depends on the paint type and recoat interval, so agree it with the supplier. Thixotropy and viscosity recovery are measured with laboratory instruments, and where film thickness determines performance, as in anticorrosion work, do not sign off on floor judgement alone; have the coating inspector confirm.

Thinners and solvent-borne paints ignite easily and their vapours harm health, so follow the product's safety data sheet, the SDS, for ventilation, protective equipment and control of ignition sources. Spray operations carry both physical and health hazards (OSHA, n.d.). When warming paint, never use a flame or direct heat; use only methods the TDS allows, and when painting in a confined space such as the inside of a tank, provide ventilation and a standby attendant.

Sources

  1. ASTM International. (2018). ASTM D4400-18, Standard test method for sag resistance of paints using a multinotch applicator. https://store.astm.org/d4400-18.html
  2. Barnes, H. A. (1997). Thixotropy—a review. Journal of Non-Newtonian Fluid Mechanics, 70(1–2), 1–33. https://doi.org/10.1016/S0377-0257(97)00004-9
  3. Bosma, M., Brinkhuis, R., Coopmans, J., & Reuvers, B. (2006). The role of sag control agents in optimizing the sag/leveling balance and a new powerful tool to study this. Progress in Organic Coatings, 55(2), 97–104. https://doi.org/10.1016/j.porgcoat.2005.08.008
  4. Eley, R. R., & Schwartz, L. W. (2002). Interaction of rheology, geometry, and process in coating flow. Journal of Coatings Technology, 74(932), 43–53. https://doi.org/10.1007/BF02697974
  5. International Organization for Standardization [ISO]. (2003). ISO 16862:2003, Paints and varnishes — Evaluation of sag resistance. https://www.iso.org/standard/31110.html
  6. Issa, M. W., Yu, H., Roffin, M. C., Barancyk, S. V., Rock, R. M., Gilchrist, J. F., & Wirth, C. L. (2022). Three-dimensional sag tracking in falling liquid films. Langmuir, 38(38), 11581–11589. https://doi.org/10.1021/acs.langmuir.2c01232
  7. Lade, R. K., Musliner, A. D., Macosko, C. W., & Francis, L. F. (2015). Evaluating sag resistance with a multinotched applicator: Correlation with surface flow measurements and practical recommendations. Journal of Coatings Technology and Research, 12(5), 809–817. https://doi.org/10.1007/s11998-015-9680-5
  8. Mewis, J., & Wagner, N. J. (2009). Thixotropy. Advances in Colloid and Interface Science, 147–148, 214–227. https://doi.org/10.1016/j.cis.2008.09.005
  9. Occupational Safety and Health Administration [OSHA]. (n.d.). Spray operations. U.S. Department of Labor. Retrieved November 2026. https://www.osha.gov/spray-operations
  10. U.S. Army Corps of Engineers [USACE]. (1995). Painting: New construction and maintenance (EM 1110-2-3400). Department of the Army.
  11. U.S. Department of Defense [DoD]. (2021). UFC 3-190-06, Protective coatings and paints. https://www.wbdg.org/FFC/DOD/UFC/ufc_3_190_06_2021.pdf
  12. Waggoner, R. A., & Blum, F. D. (1989). Solvent diffusion and drying of coatings. Journal of Coatings Technology. https://scholarsmine.mst.edu/chem_facwork/1379
  13. Wu, S. (1978a). Rheology of high solid coatings. I. Analysis of sagging and slumping. Journal of Applied Polymer Science, 22(10), 2769–2782. https://doi.org/10.1002/app.1978.070221005
  14. Wu, S. (1978b). Rheology of high solid coatings. II. Analysis of combined sagging and leveling. Journal of Applied Polymer Science, 22(10), 2783–2791. https://doi.org/10.1002/app.1978.070221006

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07