KALTECKOREA

BlogApplication notes

Why does plating burn and roughen at the edges?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Coatings & Surface Treatments

Turning down the rectifier is the usual response to burnt edges, but that leaves the flat faces short of thickness and does nothing about why current crowds onto the edges. What actually lies behind it can be high current density, weak agitation, bath concentration and temperature out of range, unbalanced brighteners or poor racking, and sometimes two or more at once.

Background

The broad faces of parts coming off the rack are evenly bright, but the edges, ends and hole rims are rough, grey or black as if scorched, and powder comes away under a fingernail. Such parts must be stripped and replated or scrapped, and rough edges can snag in assembly or lift the next layer plated over them. As metal piles onto the edges, the broad faces end up thinner, and extending plating time to reach the specified thickness only burns the edges further.

The thickness and appearance of a deposit are set by how much current flows at each spot, the local current density. Because of the shape and arrangement of the electrodes, current does not spread evenly; on a flat electrode, current density is highest at the four corners and lowest at the centre (Dukovic, 1990). Current density also has a ceiling, set by how fast the bath can carry metal ions to the surface, and as current density approaches this limiting current density, the deposit changes from a compact layer to powder or branching growths (Winand, 1992). A burnt deposit means the current at that spot exceeded what the bath could sustain, and edges reach that line first.

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: photograph the burnt parts and where they hung on the rack, then compare the rectifier current and voltage at the time, the surface area of the load, and the bath temperature and analysis with the ranges in the plating chemistry supplier's TDS.

Hypothesis 1: high current density

When the rectifier setting is large for the true area of the load, burning starts at the edges. It happens when current is raised and time cut to meet output, when a half-filled rack runs at the usual current, when a new part's area is estimated roughly from the drawing, and when full current is applied at once instead of being ramped. Say that in a rush week the rectifier current goes up a step to build the same thickness in less time. The flat parts turn dark grey from the four corners in, while their broad faces shine as usual.

The rectifier sets the average current density; the value each spot on the part receives is set by shape. In the primary current distribution, which ignores the resistance of the electrode reaction, current density at an electrode edge becomes infinite in theory, and in practice edge current density sits above the average (Dukovic, 1990). Metal ions must diffuse in from the bath as fast as they are consumed at the surface; the current at which surface concentration approaches zero is the limiting current, and any current beyond it is taken by other reactions such as hydrogen evolution (Newman & Thomas-Alyea, 2004). Raise the average and the edges reach this limit first, where the deposit can no longer build evenly and grows as powder and nodules (Winand, 1992).

Start by recounting the numbers. Add up the surface area of each part on the rack from drawings or measurement, divide the rectifier current by it to get the average current density, and compare that with the TDS operating range. Plate a test panel in a Hull cell with a sample of the bath; current density varies continuously along one panel, so the point where burning begins can be read off (DIN, 2016). On the burnt parts, measure thickness at the edge and the centre with an X-ray fluorescence gauge and record the difference (ASTM International, 2021).

If current density is the cause, build the habit of setting the rectifier by area. Tabulate the surface area of each part, set current by the quantity on the rack, and when a rack is short, lower the current or fill the gaps with dummy panels. If more thickness is needed, extend time rather than raise current, and ramp the current up at the start as the TDS recommends. The working rule is to keep a margin between the operating value and the burn onset read from the Hull cell.

Hypothesis 2: poor agitation

When burnt parts cluster at one end of the tank or where flow does not reach, look at agitation. It happens when holes in the air sparger clog with sludge, when a blocked filter cuts circulation, when the cathode rocker has stopped or its stroke has shortened, and when parts hang so close together that solution does not move between them. Seen from above, an air-agitated tank may have one end where no bubbles rise. Only the parts hung beneath it burn at the edges, while parts at the end with even bubbling come out sound.

The limiting current density is proportional to the concentration and diffusion coefficient of the metal ion and inversely proportional to the thickness of the diffusion layer that forms in front of the surface. Agitation thins this layer and raises the limit in the same bath, while weak agitation thickens it and lowers the limit (Newman & Thomas-Alyea, 2004). Uneven agitation makes mass transfer differ from place to place, so current distribution becomes uneven regardless of electrode shape (Dukovic, 1990). Edges in weak-flow zones combine an already high current density with a lowered limit, and burn first.

Lay a map of the burnt spots over a map of the agitation. For air agitation, watch the bubble pattern during operation and check that sparger holes are evenly open; for circulation, check flow with a flowmeter or the pressure difference across the filter. Measure the stroke length and speed of the cathode rocker. Note whether burns also cluster where solution tends to stagnate, such as between closely spaced parts or in deep recesses.

Once narrowed to agitation, clean clogged sparger holes and filters, and aim pipes and nozzles so that flow passes evenly through the whole tank. Return the rocker to its design stroke and space parts far enough apart for solution to flow between them. The right type and strength of agitation differ by plating process, so check the TDS and the supplier's advice before adding air agitation or making it stronger.

Hypothesis 3: bath out of range

When neither current nor agitation has changed but edges start burning one day, what has changed may be the bath itself. It happens when metal is not replenished as fast as it leaves with drag-out, when anodes stop dissolving and supply less metal, when a heater or temperature controller fails, when production starts before a bath that cooled over the weekend is fully reheated, and when pH drifts outside the TDS range. If only the first rack on Monday morning burns at the edges and parts are sound from around midday, the first question is how the bath temperature climbed in between.

The concentration and diffusion coefficient that set the limiting current density depend on exactly these conditions. Lower metal ion concentration lowers the limit in proportion, and a cold bath is more viscous, so ions diffuse more slowly and the limit falls with it (Newman & Thomas-Alyea, 2004). Temperature also affects current distribution. How evenly current spreads is described by the Wagner number, a dimensionless group combining bath conductivity with the resistance of the electrode reaction, and the smaller it is, the more current follows the shape and crowds onto edges (Dukovic, 1990). A cold bath has lower conductivity, so with other conditions equal its Wagner number falls and the edges can take a larger share at the same average current. The edges then face a lowered limit and a larger share together.

Set the bath analysis and temperature records beside the TDS ranges. Analyse metal concentration, conducting salt or acid content and pH by the specified methods, and cross-check the bath thermometer with a separate one. Pull the anodes and see whether they are dissolving evenly or are coated with a film. Matching the burn dates against analysis, replenishment and heater logs shows which conditions moved together.

If bath conditions are the cause, set a procedure for bringing them back in range. Replenish metal from the analysis, and check anode area and condition so dissolution keeps pace with consumption. Put the first rack into a cooled bath only after confirming it has reached the TDS temperature, rather than running it beforehand at reduced current. Shorten the analysis interval to suit output, and keep the results alongside the burn reject log.

Hypothesis 4: brightener imbalance

When edges turn dull and rough after additions, or in a bath long overdue for carbon treatment, look at the brighteners. It happens when the setting of an ampere-hour dosing pump has changed, when a large amount is added by hand at once, or when breakdown products build up. One example: brightener is added generously after a report of lost lustre, and the next day the broad faces shine again while the dull band at the edges has actually widened.

Additives adsorb on the cathode surface and change how crystals grow, and some are taken into the deposit. Levellers and brighteners reach fast-diffusion spots, protrusions and edges, more readily and slow deposition there, which is how they even out the surface (Oniciu & Mureşan, 1991; Plieth, 1992). In acid copper plating, suppressors and levellers that hold back deposition and accelerators that promote it act together with chloride and copper ions, so an excess or shortfall of any one changes the effect of the whole (Vereecken et al., 2005). Bright nickel plating also uses brighteners with different roles together, and their concentrations and accumulated breakdown products are managed by analysis and carbon treatment (Schlesinger & Paunovic, 2010). Once the balance is lost, the usable range at the high-current end can narrow, and edges may burn at a lower current density than usual.

The Hull cell panel is most useful here. Plate a panel from the working bath and one from a reference bath freshly made up to the TDS under the same conditions, lay them side by side, and compare where burning starts and the bright range (DIN, 2016). Re-running panels from the working-bath sample with small additions of brightener, or after carbon treatment, narrows down which component is short or in excess. Also tally the addition log against the ampere-hour record to see whether actual dosing followed the TDS replenishment rate.

For a brightener problem, change how additions are made. Rather than large manual doses, add small amounts in step with ampere-hours, and fix the quantity only after confirming it with a Hull cell test. If breakdown products have built up, carbon-treat by the supplier's method and restore the additives removed by the treatment.

Hypothesis 5: poor racking

Burns confined, within one rack, to the parts in the outer columns, the bottom row or the side nearest the anode point to the racking. It happens when a new part goes onto an existing rack unchanged, when sharp ends of the part face the anode, when anodes are longer than the rack or hang lower than it, and when the anode is close to the work. Write the rack position number on each burnt part and the marks gather in the two outer columns and the bottom row, while parts in the middle are sound under the same time and current.

Current distribution is set not only by the shape of one part but by the arrangement of the whole rack, the anodes and the tank walls. Parts at the outside and ends of a rack draw extra current from the surrounding solution, so they act as the edges of one large electrode, and their own edges in turn take the largest share within that (Dukovic, 1990). Placing an auxiliary electrode, a thief, beside the work to share the current can improve thickness uniformity, with the effect depending on thief size, its distance from the work and the current applied to it (Mehdizadeh et al., 1990). Shields that block current and shaped anodes serve the same purpose.

Confirm through records by position. Number each rack position, collect where burnt parts hung over several loads, and pick a few outer and middle parts to measure thickness at the edge and on the broad face with the X-ray fluorescence gauge. Compare anode length and height with the rack, and check that the anode-to-rack distance matches the TDS or the equipment standard. Photograph which end of each part faces the anode as well.

If the arrangement is the cause, rework the rack. Put thief bars or dummy panels in the outer columns and bottom row instead of parts so they take the crowding current, and change the hanging direction so sharp ends do not face the anode head-on. Set anodes slightly shorter than the rack and higher, and fit shields where needed. After the change, measure thickness again at the same positions and record the effect in numbers.

Finding the cause

Three of the five hypotheses can be checked at the tankside straight away. Rectifier current against load area takes one calculation, and bath temperature and agitation can be confirmed by eye and thermometer. Bath analysis and a Hull cell test need only a sample and leave production running, so they come next, and trials that disturb production, such as changing the racking, come last.

The distribution of burns points the way. Burnt edges on every part regardless of rack position, worse on days when the rack is short, point to current density; burns gathered at one end of the tank or where flow does not reach point to agitation; burns concentrated on Monday mornings or after late replenishment point to bath temperature and concentration. If burning began after an addition, look at brightener balance, and if it appears only in the outer columns and bottom row of the same rack, look at racking.

The Hull cell becomes a control test that separates tank problems from bath problems. If panels from the working bath and the fresh reference bath begin burning at the same current density, the bath is doing its job, so look at current, agitation and racking; if the working-bath panel burns at a lower current density, look at concentration and brighteners (DIN, 2016). Both panels are plated at the same temperature, so check bath temperature separately with a thermometer. In the tank, change only one thing at a time, such as dropping current one step, restoring agitation or hanging dummy panels in the outer columns, or there is no telling which one worked.

The final check is thickness distribution. After the fix, measure edge and broad-face thickness again on parts from the same positions, and see whether the gap between them has narrowed as well as whether edge appearance has recovered. If appearance improves but the broad face is below specification, lowering the current has merely hidden the burning, and the cause is still there.

The hypotheses can overlap. A cold bath with weak agitation lowers the limiting current density twice over, and when the high share of outer-column parts and a high average current are added on top, fixing any one alone may not stop the burning. In such cases, bring the bath back in range first, concentration, temperature and brighteners, then deal with agitation, current and racking in that order, because while the bath is unsettled, the effect of changing the rack or current cannot be compared fairly.

Limits and cautions

Suitable current density, bath metal concentration and temperature, pH, and additive concentration and replenishment rate differ by plating process and supplier formulation, so numeric decisions follow the TDS for that chemistry. Hull cell current, time and temperature also differ by plating process, so follow the supplier's method. For parts whose thickness and hydrogen embrittlement control are governed by specification, such as aerospace or automotive safety parts, do not decide on replating or release from floor judgement alone; get the quality engineer to confirm.

For plating solutions, acids and additives, follow each product's safety data sheet, the SDS, for protective equipment and ventilation. Hexavalent chromium from chromic acid plating can cause lung cancer when inhaled and also harms skin and eyes, so exposure must be controlled (OSHA, n.d.). High currents release hydrogen, so keep extraction running over the tank and keep sparks away, and handle racks only after the rectifier is off. Keep cyanide plating solutions apart from acids at all times.

Sources

  1. ASTM International. (2021). ASTM B568-98(2021), Standard test method for measurement of coating thickness by X-ray spectrometry. https://store.astm.org/b0568-98r21.html
  2. Deutsches Institut für Normung [DIN]. (2016). DIN 50957-1:2016-02, Testing of electrolytes used for electro-deposited metallic coatings — Part 1: Standard Hull cell. https://www.dinmedia.de/en/standard/din-50957-1/244354430
  3. Dukovic, J. O. (1990). Computation of current distribution in electrodeposition, a review. IBM Journal of Research and Development, 34(5), 693–705. https://doi.org/10.1147/rd.345.0693
  4. Mehdizadeh, S., Dukovic, J., Andricacos, P. C., Romankiw, L. T., & Cheh, H. Y. (1990). Optimization of electrodeposit uniformity by the use of auxiliary electrodes. Journal of The Electrochemical Society, 137(1), 110–117. https://doi.org/10.1149/1.2086343
  5. Newman, J., & Thomas-Alyea, K. E. (2004). Electrochemical systems (3rd ed.). Wiley.
  6. Occupational Safety and Health Administration [OSHA]. (n.d.). Hexavalent chromium. U.S. Department of Labor. Retrieved November 2026. https://www.osha.gov/hexavalent-chromium
  7. Oniciu, L., & Mureşan, L. (1991). Some fundamental aspects of levelling and brightening in metal electrodeposition. Journal of Applied Electrochemistry, 21(7), 565–574. https://doi.org/10.1007/BF01024843
  8. Plieth, W. (1992). Additives in the electrocrystallization process. Electrochimica Acta, 37(12), 2115–2121. https://doi.org/10.1016/0013-4686(92)85101-P
  9. Schlesinger, M., & Paunovic, M. (Eds.). (2010). Modern electroplating (5th ed.). Wiley. https://doi.org/10.1002/9780470602638
  10. Vereecken, P. M., Binstead, R. A., Deligianni, H., & Andricacos, P. C. (2005). The chemistry of additives in damascene copper plating. IBM Journal of Research and Development, 49(1), 3–18. https://doi.org/10.1147/rd.491.0003
  11. Winand, R. (1992). Electrocrystallization — theory and applications. Hydrometallurgy, 29(1–3), 567–598. https://doi.org/10.1016/0304-386X(92)90033-V

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.