KALTECKOREA

BlogApplication notes

Why does the rolling mill use so much rolling oil?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Metalworking Fluids (MWF)

Cutting top-ups or looking for a cheaper rolling oil is the usual response to high oil use, but cutting the amount without knowing where the oil leaves tends to starve lubrication and unsettle strip quality. What actually drives it can be carry-out on the strip, emulsion dumped after oil leaks, an unstable emulsion, filter and skimmer losses, concentration set too high or direct application, and sometimes two or more at once.

Background

The month-end purchasing report shows noticeably more drums of rolling oil than last month, while the tonnage rolled has barely moved. When rolling oil use per tonne of output rises, the oil bill is not the only cost. More emulsion is thrown away, so waste treatment cost and discharge load grow with it, and more oil left on the strip can unsettle cleanliness in later steps such as annealing and plating.

Cold rolling lubricates and cools the rolls and strip by spraying an emulsion of palm oil or synthetic oil in water (EPA, 2002). Recirculation, which collects the emulsion and reuses it, consumes little oil, while direct application, which uses it once and throws it away, gives good lubrication and cleanliness at the cost of high oil consumption and a large volume of waste lubricant to treat (Cui et al., 2019). Either way, the oil put into the tank leaves by a few routes: carried out on the strip, sent away with dumped emulsion, or removed with filter waste and skimmed oil.

So the question of why consumption has risen becomes a search for which of these routes has widened. Each route has its own way of being measured, so balancing the oil going in against the oil going out on a single sheet makes the cause easier to narrow.

In such cases the technical team sets up the six hypotheses below and rules them out one by one. The start is always the same: gather the last few months of rolling oil additions, tonnage, tank renewals and waste emulsion removals, plot consumption per tonne by date, and compare the emulsion analysis with the ranges in the rolling oil's technical data sheet, the TDS.

Hypothesis 1: carry-out on the strip

The whole point of rolling oil is to build an oil film on the strip, so some oil always leaves on it. The trouble starts when that amount grows: when the wipers or air nozzles that strip liquid off the strip are worn, when wider or thinner products take a larger share and the rolled area grows, or when the distance between nozzles and roll bite has been changed. Some days more oily water than usual collects in the trays under the exit roller table, and oil runs down the sides of the wound coils.

Oil on the strip comes from plate-out, the conversion of emulsion into an oil film when it meets the strip, and the amount grows with time. In a study that measured plate-out over short times, more oil deposited the longer the time between emulsion supply and contact with the strip, and concentration and droplet size also changed the amount (Kimura et al., 2009). A study of double cold rolling separated the share of emulsion that remains on the strip surface from the share of oil in that emulsion that plates out, the first depending on emulsion volume per strip area and plate-out time, the second on the oil's wettability, concentration and plate-out time (Cui et al., 2019). That is why a change in any one of nozzle position, concentration or area changes how much oil the strip takes away.

The oil the strip takes away can be measured directly. Cut a set area of strip after the last stand, wash it with solvent and weigh it before and after; multiply the oil per area by the area rolled that day for an estimate of the oil carried out. Set this beside the additions and compare over several weeks. Record wiper wear, air nozzle pressure and angle, and how much liquid gathers in the exit trays as well.

If the strip's share has grown, work on both the stripping side and the spraying side. Replace worn wipers and set the air nozzles to cover the full strip width evenly. Reset nozzle position and spray volume so that only as much reaches the strip as lubrication needs, and watch roll force and strip surface after the change. Oil left on the strip also feeds stains further down the line, so share the results with the annealing team.

Hypothesis 2: dumping after oil leaks

Hydraulic cylinders, gearboxes and bearing lubrication systems crowd around a rolling mill. Consider this hypothesis when seals are ageing, when pipe joints were left loose after maintenance, or when lube oil top-ups have grown more frequent and nobody has asked why. The hydraulic tank is refilled several times a month with no leak marks on the floor, while over the same period a dark oil layer thickens on the emulsion tank until part of it is drained and refilled.

Leaked-in oil, or tramp oil, is oil that was never meant to be in the emulsion: hydraulic fluid, gear oil, spindle oil, way lube and grease (OSHA, n.d.). It brings in components foreign to the rolling oil's formulation and can stay on the strip and leave residue in annealing, which is why contaminants common in rolling systems have been screened by their annealing residue (Sech & Kleksiak, 1996). In cutting fluids, continuous hydraulic oil ingress could shift tool life and wear by about 70% (Khan et al., 2021). So contaminated emulsion ends up being drained and replaced, and what is thrown away is not only the leaked oil but sound rolling oil with it.

Balance oil in and out in the books. Total top-ups of hydraulic fluid, gear oil and lube oil by system, and flag systems that take a lot of top-up with no leak on the floor. Collect oil that rises out of the emulsion and send it for analysis of foreign components; gas chromatography is one way to measure the amount of tramp oil (Khan et al., 2021). Match the dates and reasons for tank drains against the records, and count separately the rolling oil discarded because of leaked oil.

The first fix is to stop the leaks. Check seals and joints starting with the systems that take the most top-up, and add a leak check to the job sequence after maintenance. Skim off oil that has already mixed in before draining the whole tank (OSHA, n.d.), and since recovering and reusing oil from spent emulsions has been studied (European Commission, n.d.), discuss with the supplier whether recovery is feasible.

Hypothesis 3: unstable emulsion

Once an emulsion starts to split into oil and water, the oil goes somewhere other than lubrication. Suspect this when make-up water hardness or pH has changed, when tank temperature swings widely with the season, when agitation or circulation pumps have been changed, or when leaked oil or iron fines have built up. A look into the tank in the morning shows a yellowish oil layer on top, and separated oil runs out first from pipe ends that stood still overnight.

A rolling emulsion has to split to the right degree for oil to plate out on the strip in the roll bite. The way oil separates from the emulsion has been reported to control the friction coefficient in the roll bite, with water hardness, pH, agitation and temperature bearing directly on long-term stability (Paul et al., 2015). The dispersion stability of rolling emulsions is measured by a standard test method, and the standard notes that each mill needs a different degree of stability (ASTM International, 2022). Oil that splits out too early floats up and is removed by skimmers and filters, and scum formed from iron fines lowers stability further (Wang et al., 2025).

Stability can be followed in numbers. Leave a tank sample to stand for a set time, then measure oil concentration at the top and bottom, and run the same test on emulsion made from fresh rolling oil as a baseline. Line up droplet size, make-up water hardness and pH, tank temperature and iron on the same dates, and see whether shifts in stability coincide with more skimmed oil or filter waste.

To restore stability, reverse whatever upset it first. Set limits for make-up water hardness and pH and treat the water when it drifts, and keep tank temperature within the TDS range. Skim off leaked oil and scum, and look at iron fines control too. A change of formulation is another route to review with the supplier; a rolling oil with a cationic emulsifier was reported to keep a stable emulsion in laboratory and mill trials while dispersing fines well (Inagaki et al., 2017).

Hypothesis 4: filters and skimmers

A recirculating system carries several devices that keep the emulsion clean, and each one sends something out. This route widens when the filter medium is changed to a finer grade, when backwash or media index intervals are shortened, or when skimmers are set to run all the time. The waste bin under the filter fills faster than before, and what is in it shines like oil-soaked mud rather than dry powder.

Recirculating cold rolling uses paper, cloth or plastic filters to remove accumulated solids and magnetic separators to take out iron fines, extending emulsion life. Well-designed magnetic separators can hold iron in rolling solutions below 100 ppm, and the removed solids are usually shipped off site for disposal (EPA, 2002). Removed solids leave wet with oil and water, not as dry iron powder, so more waste also means more rolling oil leaving with it. A skimmer removes oil that rises to the top of a still tank (OSHA, n.d.), so when an unstable emulsion lets rolling oil rise too, the skimmer takes rolling oil away along with the tramp oil.

Catch what leaves and measure it. Collect filter waste and magnetic separator waste over a set period, weigh it, and extract a sample with solvent to find its oil content. Collect the skimmer's oil in a drum, measure it, and have a sample analysed for the split between rolling oil and leaked-in oil. Seeing what share of total consumption these two add up to shows how they relate to the dates when filter media or skimmer settings were changed.

If losses through the cleaning devices are large, rebalance cleanliness against oil loss. As far as the emulsion's iron and cleanliness targets allow, move back to a coarser filter medium and a slower index rate, and place skimmers where the liquid has time to settle, adjusting run time so they take mainly the tramp oil that has risen. If skimmed oil comes out rich in rolling oil, look at emulsion stability before the skimmer.

Hypothesis 5: excess concentration

After strip surface defects or roll wear, emulsion concentration is sometimes raised generously and left there. Typical cases are keeping the concentration raised for high-strength trials after returning to ordinary steel, a change of measuring method that reads lower than the true value, and a top-up rule set near the upper limit. Since the month of a quality problem, the target on the top-up chart has stayed one step higher, and the analysis always sits at the top end of the TDS range.

Raising concentration does more than increase the total oil in the tank. Oil plating out on the strip also grows with concentration, so the strip's share grows (Kimura et al., 2009), and in a laboratory mill study, higher emulsion concentration produced more iron fines (Wang et al., 2025). More fines mean more oil leaving with filter waste and scum. On the other hand, supplying more oil at the last stand reduced smudge at the strip edges (Komai et al., 1981), so oil may have been raised for a quality reason, and any reduction must keep that reason in view.

First check that the measurement is right. Compare floor readings with laboratory analysis of the same sample on the same day, and confirm the reading matches the true value. Then find in the records when and why the target concentration went up, and whether strip defects, roll wear and roll force actually changed afterwards. If defects did not fall after concentration was raised, the case that high concentration is preventing them is weak.

Metalworking fluid management guidance notes that too high a concentration can bring foaming and heavy residues (OSHA, n.d.), so there are reasons to lower it beyond consumption alone. Even so, lower concentration in steps rather than all at once. After each step, record roll force, strip surface, roll wear and consumption together for a set period, and take the concentration just above where quality indicators begin to move as the new target. If different grades or gauges need different concentrations, review setting targets by product group with the supplier.

Hypothesis 6: direct application

Sometimes the mill's own design sets consumption. If consumption is high on a mill making thin, high-strength strip that must be very clean, a mill where one or two stands use emulsion once and discard it, or a mill that mixes recirculation and direct application, check the system first. A comparison with a recirculating mill at another plant shows a wide gap, and on this mill the emulsion sprayed onto the strip runs straight into the drain.

Direct application sprays a small volume of high-concentration emulsion straight onto the strip, while recirculation sends a large volume of low-concentration emulsion to the roll bite and uses it again. The same study credits direct application with good lubrication and cleanliness, yet notes that its once-through use means high oil consumption and a large volume of waste lubricant to treat, with oil consumption rising with emulsion flow and concentration (Cui et al., 2019). In data from the U.S. Environmental Protection Agency, the median wastewater discharge per ton of output for multi-stand mills was about 199 gallons with direct application and about 14 gallons with recirculation (EPA, 2002).

A fair comparison sets like against like. Confirm from the piping drawings whether each stand's emulsion is used once and discarded or collected and reused, and measure flow and concentration on the direct application stands. When comparing consumption with other mills, set side by side only those with the same system, gauge and grade. If there is a direct application section, multiply its flow by its concentration to estimate what share of consumption leaves there.

When the direct application section turns out to take a large share of consumption, find the optimum flow and concentration there first. The same study reported that the combined cost of rolling energy and oil first fell and then rose with flow and concentration, reaching a minimum at a certain value (Cui et al., 2019). Where product requirements allow, review with the equipment supplier whether to shorten the direct application section or use a hybrid of the two systems. Changing the system bears directly on lubrication and surface quality, so decide only after trial rolling.

Finding the cause

Before investigating six hypotheses one by one, draw up a single oil balance sheet. Additions are already in the purchasing records and dumped emulsion in the removal records, residual oil on the strip and oil in the waste are measured on a few samples, and system and piping are confirmed from drawings.

The first clue is which route has widened. If dumped emulsion takes a large share, look at why the tank was drained to tell leaked oil from a collapsed emulsion. If filter waste and skimmed oil take a large share, look at how the filters and skimmers are run, and if that oil is rich in rolling oil, at emulsion stability. If the strip takes a large share, suspect the wipers and nozzles, and the concentration. If no route stands out yet consumption is high, look at design and targets, such as the system and the concentration setting.

Next is timing. Set the dates when consumption rose beside maintenance, filter media changes, skimmer setting changes, concentration target changes and shifts in product mix. A step change points first to the day something was changed; a slow climb points first to something that wears, such as seals or wipers.

If that still does not settle it, run control trials. Change one thing per period, for example only skimmer run time in one period and only a one-step drop in concentration in another. Record consumption, roll force and strip surface on the same basis for each period and compare with the period before the change. The job is done only when consumption falls and quality indicators hold.

The hypotheses can overlap. Leaked oil unsettles the emulsion, an unsettled emulsion sends more rolling oil out through skimmers and filters, and in the end the tank is drained. High concentration adds fines and turns the same loop faster. In such cases, stop the leaks and restore emulsion stability first, then adjust concentration and cleaning device settings, because while the emulsion is unsettled, the effect of changing concentration or filter settings cannot be compared fairly.

Limits and cautions

Suitable emulsion concentration, temperature, droplet size, iron limits and filter settings differ by mill, steel grade and rolling oil, so numeric decisions follow the rolling oil's TDS and the mill and filter suppliers' guidance. Lowering concentration or changing the system bears directly on lubrication, strip surface and roll life, so do not decide on floor judgement alone without trial rolling and quality checks. Dispose of spent emulsion, filter waste and skimmed oil under local waste and discharge rules.

Safety matters too. Metalworking fluids such as rolling emulsions can harm health through skin contact and breathing in mist, and tramp oil is named as one of the main causes of dermatitis (OSHA, n.d.). When working on tanks and filters, follow the product's safety data sheet, the SDS, for gloves, eye protection and ventilation, and stop and lock out equipment before opening waste bins or pipework.

Sources

  1. ASTM International. (2022). ASTM D3342-22, Standard test method for dispersion stability of new (unused) rolling oil dispersions in water. https://store.astm.org/d3342-22.html
  2. Cui, Y., Wang, X., Dong, H., & Bai, Z. (2019). Comprehensive optimization control technology of rolling energy and oil consumption in double cold rolling. ISIJ International, 59(6), 1081–1088. https://doi.org/10.2355/isijinternational.ISIJINT-2018-723
  3. European Commission. (n.d.). Optimisation of rolling lubricants for improved operation of cold rolling mills, OPTILUB, RFSR-CT-2004-00019. CORDIS. Retrieved November 2026. https://cordis.europa.eu/project/id/RFSR-CT-2004-00019
  4. Inagaki, S., Ishii, T., Hu, Q., Ren, X. P., & Wakimoto, M. (2017). Development of rolling oil with cationic emulsifier for sheet gauge cold rolling. Tetsu-to-Hagane, 103(3), 134–141. https://doi.org/10.2355/tetsutohagane.TETSU-2016-055
  5. Khan, T., Broderick, M., & Taylor, C. M. (2021). Investigating the industrial impact of hydraulic oil contamination on tool wear during machining and the development of a novel quantification methodology. The International Journal of Advanced Manufacturing Technology, 112(1–2), 589–600. https://doi.org/10.1007/s00170-020-06370-y
  6. Kimura, Y., Fujita, N., & Mihara, Y. (2009). Plate-out behaviors of O/W emulsions for cold rolling in a short time interval. Tetsu-to-Hagane, 95(4), 340–346. https://doi.org/10.2355/tetsutohagane.95.340
  7. Komai, M., Fukuyama, S., Sato, T., & Iketaka, S. (1981). Formation of smudges and iron oxide film in the course of cold rolling. Tetsu-to-Hagane, 67(10), 1763–1769. https://doi.org/10.2355/tetsutohagane1955.67.10_1763
  8. Occupational Safety and Health Administration [OSHA]. (n.d.). Metalworking fluids: Safety and health best practices manual. U.S. Department of Labor. Retrieved November 2026. https://www.osha.gov/metalworking-fluids/manual
  9. Paul, S., Datta, S., Sivasurian, N., Saxena, D., Sayanna, E., & Suresh, R. (2015). Study of emulsion stability of rolling oils [Extended abstract]. STLE Annual Meeting. https://stle.org/Shared_Content/Extended_Abstracts/EA_AM2015/Metalworking_Fluids/Study%20of%20Emulsion%20Stability%20of%20Rolling%20Oils.aspx
  10. Sech, J. M., & Kleksiak, T. P. (1996). The evaluation of rolling oils used in the cold rolling of sheet steel by thermogravimetry. In Proceedings of the 33rd Rolling Seminar (pp. 325–340). ABM. https://doi.org/10.5151/2594-5297-LA5749
  11. U.S. Environmental Protection Agency [EPA]. (2002). Development document for final effluent limitations guidelines and standards for the iron and steel manufacturing point source category (EPA-821-R-02-004). https://www.epa.gov/sites/default/files/2015-10/documents/ironsteel_dd_2002.pdf
  12. Wang, D.-M., Inagaki, S., & Shiota, R. (2025). Factors affecting generation of iron fines in cold sheet rolling of steel. ISIJ International, 65(9), 1331–1338. https://doi.org/10.2355/isijinternational.ISIJINT-2025-124

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.