Opening a new can is the usual response when a spray weakens in winter, on the belief that the old one is nearly empty, but the pressure of a liquefied propellant is set by temperature, not by how much is left, so a cold new can sprays just as weakly. What actually lies behind it can be low propellant pressure, thickened contents, a clogged nozzle, contents settled for lack of shaking, or propellant lost by spraying upside down, and sometimes two or more at once.

Background

On a morning below freezing, a lubricant spray aimed at a chain in the outdoor yard spits coarse drops instead of a fine mist, hisses for a few presses and then dribbles again. The chain ends up blotchy, and the same can behaves nothing like it does on days when it was kept in the office.

A patchy film does not lubricate chains and gears evenly, and with a rust preventive, rust starts first where coverage is thin. Drops that pile up in one spot run off and are wasted, and cans with product still inside may be thrown away as empty. Days like this also breed the dangerous habit of warming cans quickly with a flame or a heat gun.

An aerosol can holds the product to be sprayed together with the propellant that pushes it out. The pressure exerted by a single liquefied gas propellant, which sits as a liquid in the can, depends only on temperature and not on how much liquid is left, whereas with a compressed gas propellant the pressure falls progressively as the contents are used (Dyson, 1963). Pressing the valve lets this pressure drive the product through a narrow nozzle hole, and the fast liquid breaks up into fine drops in the air to form the spray. The more viscous the liquid and the lower the driving pressure, the coarser the drops and the harder they are to break up (Lefebvre & McDonell, 2017).

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: find out where the can was kept before use, for how long and at what temperature, then look up the operating temperature range, propellant type, and instructions on shaking and spray direction on the label and in the technical data sheet, the TDS, and compare them with how the job was actually done.

Hypothesis 1: low can pressure

If cans were kept in an unheated store, an outdoor container or a work vehicle parked overnight, suspect pressure first. Long, continuous spraying lowers it too. A can that spent the night in a service van below freezing is taken out for the first job of the morning. The first few presses come out passably, but the longer the button is held the weaker the spray, and the can feels colder and colder in the hand.

The pressure drops because of the propellant's boiling point. Normal butane reaches a vapour pressure equal to atmospheric pressure at about 0°C, isobutane at about −11°C and propane at about −42°C (NIST, n.d.), so a can that has cooled close to those temperatures has almost no pressure left to push the liquid out. It has long been noted that a product formulated to spray at 50 to 70°F, about 10 to 21°C, will not dispense satisfactorily below freezing (Dyson, 1963). In tests on medical inhalers too, cooling device and surroundings together cut the dose reaching the lungs by 70% on average at the coldest conditions (Morin et al., 2014), and in another study drops became smaller as temperature rose (Hoye et al., 2005). Holding the button down makes the propellant in the can boil off and take heat with it, so the can cools further as it is used.

Measure the can's temperature first. Take the temperature of the can body with a surface or infrared thermometer and compare it with the operating range on the label or in the TDS. Leave one can of the same product in a room at room temperature for a few hours until the whole can has warmed through, then spray it side by side with a cold can onto cardboard from the same distance, and the difference in spray width and drop size shows at once. Check on the label whether the propellant is a liquefied gas or a compressed gas such as carbon dioxide or nitrogen. With a compressed gas, the more a can has been used, the lower its pressure.

If cold has dropped the pressure, put the warming method right. Keep the cans for the day indoors at room temperature and take them out just before work, keep them somewhere less cold outdoors, such as inside the vehicle or a pocket, and spray in short bursts. Never warm them with a flame, a heat gun or on a heater. The precautionary statements for aerosols say to protect them from sunlight and not to expose them to temperatures above 50°C (United Nations, 2023). If the product must be used regularly in cold places, ask the supplier whether a winter grade with a propellant blend that keeps pressure at low temperatures is available.

Hypothesis 2: thickened contents

The heavier the contents, the more they suffer in the cold. Products made thick to begin with, such as chain oils, open gear lubricants, wax-containing rust preventives and underbody coatings, are the ones. Even with some propellant pressure left, the spray pattern of such products breaks down first. Picture a winter job spraying a wax-based rust preventive onto steel members standing outdoors. A spray that should spread like mist comes out in thin strings or heavy blobs, leaving spots dotted over the steel.

The viscosity of petroleum liquids rises steeply as temperature falls, and the relationship is regular enough that a standard equation estimates the viscosity at another temperature from viscosities measured at two (ASTM International, 2020). Wax-containing products go further: once they cool past the cloud point, the temperature at which wax crystals first appear, solid crystals form in the liquid (ASTM International, 2023). For the liquid leaving the nozzle to break into drops it must overcome the viscosity holding it together, and when viscosity is high, break-up is delayed, so drops become coarser and the spray narrower (Lefebvre & McDonell, 2017). In winter, with pressure down as well, the two together make the spray coarse.

The spray pattern is the clue. If spraying onto cardboard gives strings or heavy drops, suspect viscosity, and see whether the pattern evens out once the same can has warmed to room temperature. When only pressure is low, the warmed can sprays evenly again, but with viscosity to blame, even a warmed product can set again and bead the moment it meets a cold surface. Look in the TDS for an application temperature and low-temperature properties such as cloud point or pour point, and compare them with the day's temperature.

If viscosity is the problem, think about the temperature of the surface as well as the can. Warm the can at room temperature before use, and build up several thin passes rather than one heavy coat. For a product that sets at once on cold metal, keep to the minimum application temperature in the TDS, and for sites colder than that, choose a low-temperature product with the supplier. Moving the job to the warmer middle of the day is another option.

Hypothesis 3: clogged nozzle

If the spray veers to one side, splits, or spits on the first press and then thins out, look at the nozzle. It often happens with products containing solid lubricants, zinc powder, wax or resin when the nozzle tip is left uncleaned, and in cans kept somewhere cold the product left at the tip sets more readily. Take a can used yesterday and put away in the toolbox without its cap, then taken out this morning. A ring of dried residue clings to the nozzle tip, and the first press sends the spray off at an angle and down over the fingers.

The shape and direction of a spray depend heavily on the size and shape of the nozzle hole (Lefebvre & McDonell, 2017). Residue stuck at the edge of the hole narrows it or skews it to one side, so less comes out and the spray goes crooked. Even precisely made medical inhalers suffer the same problem, and their label requires the actuator to be washed and air-dried at least once a week to ensure proper dosing and prevent blockage of the spray hole (Cipla USA, 2025). Wax-containing products form crystals once they drop below the cloud point in the cold (ASTM International, 2023), so narrow nozzle passages can clog more readily in winter.

Look at the nozzle tip for dried residue or white crystals. The surest check is a swap. Take the nozzle off a can of the same type that sprays well, fit it to the suspect can and spray; if the spray recovers, the nozzle was the cause. If it is still weak with the other nozzle, the problem lies inside the can, with pressure or contents.

When a clogged nozzle is confirmed, change the habits after use. At the end of a job, wipe the nozzle tip with a dry cloth and put the cap back on. Take a clogged nozzle off, soak it in a solvent the TDS allows until the residue dissolves, then refit it, and never poke the hole with a needle or wire, because a damaged hole does not give the spray back. Where the same product is used often, keeping spare nozzles to hand means fewer clogged cans thrown out whole.

Hypothesis 4: settled contents

Look at this hypothesis with products labelled to be shaken before use, that is, products with solid particles suspended in liquid. Zinc rust preventives, dry-film lubricants with molybdenum disulphide, graphite or fluoropolymer, and paint-type marking sprays are such products. The longer a can has stood on a shelf, the more has settled at the bottom. Think of a can that spent the whole winter on a store shelf being pressed straight away without shaking. At first only thin, clear liquid comes out, then a thick lump suddenly spurts, and the coated surface varies in colour and thickness from place to place.

Particles suspended in a liquid float up or sink to the bottom according to the density difference between them and the liquid, so shaking to mix them evenly is the precondition for an even spray. In a study of medical inhalers testing this principle, the delay between shaking and firing made the amount delivered from suspension products drop to 32% or rise to 380% of the label claim, while products with the drug dissolved, without particles, barely changed even unshaken (Chierici et al., 2020). If settled particles have gathered round the inlet of the dip tube at the bottom, the tube can take in first liquid with hardly any particles and then a thick lump, and the lump can block the nozzle.

Shaking the can is the first check. If the product has a mixing ball inside, it should rattle freely when shaken; if there is no sound, or only a dull one, the sediment may have packed hard at the bottom and be gripping the ball. After shaking as long as the label says, spray onto cardboard and check that colour and thickness are the same at the start and later on. If the label gives no instruction to shake, strike this hypothesis off.

If separation is the cause, build shaking into the work sequence. Shake for as long as the label says before use, and again each time work resumes after a pause. For a can packed so hard that the ball will not move, shake for longer to see whether the ball starts rolling again; if it still will not free, an even film cannot be expected, so do not use it. Using stock in the order it arrived, so cans do not sit for long, also helps.

Hypothesis 5: sprayed upside down

Spots that must be sprayed upwards, such as under a conveyor, the underside of a vehicle or a bearing near the ceiling, lead people to tilt or invert the can. In winter, with hands stiff from the cold, turning the can over is often chosen over changing position. Say the underside of a conveyor frame is being sprayed with the can upside down. The first few presses deliver product, then soon there is only the hiss of gas. If the can uses a compressed gas, turning it upright and pressing again brings out hardly anything, though it still feels heavy.

In a can with a dip tube, the pressure inside pushes the liquid up through the tube, which runs from the valve to the bottom. When the can is inverted, the end of the dip tube sits in the gas above the product, so only propellant vapour enters the tube and is sprayed out. In cans using a compressed gas propellant, venting gas this way can lose all the propellant before the product is used up, and the remaining product can no longer be dispensed (Nandagiri & Pong, 1985). In a liquefied gas can, pressure is set by temperature as long as liquid propellant remains, but every inverted spray wastes propellant, so the propellant can run out before the product does.

Asking whoever did the job how they held the can is quickest. If a can is still heavy but only hisses or delivers almost nothing, treat it as one that lost its propellant first. Check whether the label instructs upright use or states that the can works in any direction, and compare by doing the same job with a new can held upright.

If spraying upside down is the cause, find a way to reach with the can upright. Fit a thin extension tube so the can stays upright and only the tube end points upwards, or choose a product marked for use in any direction. A compressed gas can that has lost its propellant cannot be revived, so dispose of it under local rules even if product remains.

Finding the cause

Some of the five hypotheses can be cleared with a few questions. Where the can was kept, whether it was shaken and how it was held can be asked of whoever did the job, and the nozzle tip only needs a look. Can temperature takes one thermometer. Comparison with a warmed can and the nozzle swap come after.

The first clue is how the spray weakens. If it is evenly weak from start to finish, look at what moves together with temperature, low propellant pressure and thickened contents; if it is thin at first and then suddenly thick, look at contents settled for lack of shaking. A spray that veers or splits points to the nozzle, and a heavy can that only hisses points to propellant lost by spraying upside down.

If temperature looks responsible, separate pressure from viscosity. If a can warmed to room temperature returns to a fine mist and coats evenly even on a cold surface, pressure is the main cause; if even a warmed can beads or breaks into strings the moment it meets a cold surface, look at viscosity and wax crystals. With a compressed gas can, pressure falls with the amount left, so compare a well-used can and a new one at the same temperature.

If that still does not settle it, run control trials that change one thing at a time. Warm the same can at room temperature, swap the nozzle, then shake well and spray with the can upright. Change only one thing at a time, spray onto cardboard from the same distance each time and lay the marks side by side, and it becomes clear which step brought the spray back. The final check is that, with the changed method, the film goes on evenly when sprayed onto the actual cold parts on site.

The hypotheses easily overlap. On a cold day pressure is low and contents thick, residue at the nozzle tip sets more readily, and stiff hands make inverting the can tempting. In such cases, put storing cans at room temperature right first, and look for any problem that remains after shaking and upright use in the nozzle and the choice of product, because while the can is cold the effect of other measures cannot be compared fairly.

Limits and cautions

Operating temperature range, shaking time, spray direction and application temperature differ by product and propellant blend, so follow the product's label and TDS. The medical inhaler studies only illustrate the principle and do not mean changes of the same size occur in maintenance products. Dispose of cans with product remaining under local waste rules.

Safety matters too. Maintenance aerosols usually contain flammable propellant and solvent, so follow the product's safety data sheet, the SDS: keep away from sparks and hot surfaces, never warm cans with a flame, heat gun or heater or keep them above 50°C, and never pierce or burn them (United Nations, 2023). In winter, work often moves indoors with the doors shut, so ventilate to keep solvent vapour from building up, and stop the equipment before spraying moving chains and gears.

Sources

  1. ASTM International. (2020). ASTM D341-20, Standard practice for viscosity-temperature equations and charts for liquid petroleum or hydrocarbon products. https://store.astm.org/d0341-20.html
  2. ASTM International. (2023). ASTM D2500-23, Standard test method for cloud point of petroleum products and liquid fuels. https://store.astm.org/d2500-23.html
  3. Chierici, V., Cavalieri, L., Piraino, A., Paleari, D., Quarta, E., Sonvico, F., Melani, A. S., & Buttini, F. (2020). Consequences of not-shaking and shake-fire delays on the emitted dose of some commercial solution and suspension pressurized metered dose inhalers. Expert Opinion on Drug Delivery, 17(7), 1025–1039. https://doi.org/10.1080/17425247.2020.1767066
  4. Cipla USA. (2025). Albuterol sulfate inhalation aerosol: Prescribing information. DailyMed, U.S. National Library of Medicine. Retrieved November 2026. https://dailymed.nlm.nih.gov/dailymed/drugInfo.cfm?setid=fd0389e0-3713-42e0-8ef2-3bb97676fded
  5. Dyson, P. (1963). Aerosol propellants. Journal of the Society of Cosmetic Chemists, 14(8). https://library.scconline.org/v014n08/45
  6. Hoye, W. L., Mogalian, E. M., & Myrdal, P. B. (2005). Effects of extreme temperatures on drug delivery of albuterol sulfate hydrofluoroalkane inhalation aerosols. American Journal of Health-System Pharmacy, 62(21), 2271–2277. https://doi.org/10.2146/ajhp050067
  7. Lefebvre, A. H., & McDonell, V. G. (2017). Atomization and sprays (2nd ed.). CRC Press.
  8. Morin, C. M. D., Ivey, J. W., Titosky, J. T. F., Suderman, J. D., Olfert, J. S., Vehring, R., & Finlay, W. H. (2014). Performance of pressurized metered-dose inhalers at extreme temperature conditions. Journal of Pharmaceutical Sciences, 103(11), 3553–3559. https://doi.org/10.1002/jps.24145
  9. Nandagiri, A., & Pong, R. G. S. (1985). Aerosol dispensing system (U.S. Patent No. 4,546,905). U.S. Patent and Trademark Office. https://patents.google.com/patent/US4546905
  10. National Institute of Standards and Technology [NIST]. (n.d.). NIST Chemistry WebBook, NIST Standard Reference Database Number 69: Phase change data for propane, butane and isobutane. Retrieved November 2026. https://webbook.nist.gov/chemistry/
  11. United Nations. (2023). Globally harmonized system of classification and labelling of chemicals (GHS) (10th rev. ed.). United Nations. https://unece.org/transport/dangerous-goods/ghs-rev10-2023

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.