Why does water-glycol fire-resistant fluid thicken and wear the pump?

Type
Application notes
Published
23 November 2026
Prepared by
Jonghwan Moon
Product group
Equipment/Service Lubricants

Topping up with fresh fluid when viscosity rises and replacing the pump when it wears are the usual responses, but a water-glycol fluid changes its share of water and additives in service, thickening as it goes, and that change carries through to pump wear, so topping up and replacing alone tend to bring the same trouble back. What actually lies behind it can be water balance gone wrong, hot spots, spent amine inhibitor, mineral oil that got in, or air and cavitation, and sometimes two or more at once.

Background

Die-casting machines, rolling mills and presses beside melting furnaces, places where leaking fluid could catch fire at once, run on water-glycol fire-resistant fluid. After a few months the fluid in the tank is thicker than it was, the pump sounds rougher, and the vanes or piston shoes of a new pump show wear early. A pump change buys a quiet spell, then the same thing happens again, each time costing parts and downtime. The larger loss is harder to see. Fluid that has lost water may no longer have the fire resistance it was chosen for, and fluid contaminated with mineral oil can ignite more readily (ISO, 2024).

Water-glycol fluids were developed after the US Navy, having suffered shipboard fires in the Second World War, looked for hydraulic fluids more fire-resistant than mineral oil; since commercial launch in 1947 their formulations have been refined towards lower pump wear (Totten & Bishop, 1995). They consist of water, glycol, a water-soluble polymer that raises viscosity, and additives against corrosion and wear, with water usually above 35% (Danfoss, 2016). The water gives fire resistance but evaporates in service, and as it leaves the viscosity rises, so water has to be added back to keep both the fire resistance and the right viscosity (Bishop & Totten, 2003).

A fluid rich in water does not protect a pump as well as mineral oil. One pump maker's guide puts rolling bearing life in water-glycol at about 10–20% of that in mineral oil and has axial piston pumps run at 65% of their mineral oil speed rating (Danfoss, 2016). One route by which water hastens fatigue of rolling contacts, proposed early on, is hydrogen from the water diffusing into the highly stressed surface and embrittling the steel (Grunberg et al., 1960). So a water-glycol fluid's performance depends on its composition and its cleanliness together, and managing both through recommended analysis procedures can substantially improve pump life and performance (Wachter et al., 1995).

In such cases the technical team sets up the five hypotheses below and rules them out one by one. The start is always the same: measure viscosity, water content and pH on a tank sample taken that day, compare them with the new fluid and with the control ranges in the supplier's technical data sheet, the TDS, and log the tank temperature at the time and the make-up record so far.

Hypothesis 1: water balance off

Water balance has likely drifted when the tank stands open near a heat source, when the system ran hot all summer, or when a falling level has been topped up with fresh fluid rather than water. The opposite happens when water is poured in all at once or leaks in from a heat exchanger. Consider a plant where, each time the extrusion press tank level dropped, an operator filled it from a drum of fresh fluid. The level always sat at the normal mark, yet the autumn check finds viscosity above its starting value and a sound at the pump suction that was not there before.

What leaves in service is mainly water. As water goes, viscosity rises, and the fix is to put water back. Topping up with fresh fluid restores the level but not the share of water. Viscosity follows water content, so it should be read against the supplier's chart of viscosity versus water, and because oxidation and thermal breakdown lower viscosity, comparisons must be made at the same water content (Bishop & Totten, 2003). Fluid that has lost water also loses fire resistance. In tests of mining hydraulic fluids, water-glycols lost 30–40% of their original weight in oven conditioning, and the residue ignited easily in the wick test (Loftus, 1981).

Karl Fischer titration is the most direct way to measure water; on the floor a refractometer gives a quick reading but should be checked against another method from time to time (Bishop & Totten, 2003). Measure viscosity by the standard method at a fixed temperature and compare it with past values under the same conditions (ASTM International, 2024). Then open the make-up log. What went in, how much and how often shows whether fluid has been added in place of water, or water all at once. Check too whether the tank lid and breather are open and whether the tank sits near a heat source.

If water is short, add water of the specified quality in several portions, guided by the supplier's chart, until the content is back in range. Change the make-up rule so that level is restored with water and fresh fluid is added only when additives need replenishing, and measure and log viscosity and water at fixed intervals. If there is too much water, stop the heat exchanger leak first. Keep the tank closed, and if it sits by a heat source, consider shielding it or moving it.

Hypothesis 2: hot spots

The tank average can look fine while somewhere along the fluid's path it runs hot: piping past a furnace or a die, a cooler starved of cooling water, a relief valve left blowing fluid through. Picture a line where one stretch of pipe beside a melting furnace is exposed without a shield, and the cooling water valve on the cooler is still throttled from winter. The tank thermometer always shows about the same figure, yet the fluid is getting darker and no longer smells like new fluid.

Hot spots do two things: they drive water off faster, and they break the fluid itself down. A fluid's service life depends closely on operating temperature, maintenance and contamination control (ISO, 2024). When a water-glycol is overheated, small carboxylic acids such as formic and acetic acid form, and these affect pump wear and corrosion (Totten et al., 1994). One maintenance guide states that high temperature, for instance from a failed heat exchanger, oxidises the fluid and forms acids, and that formic acid above 0.15% may cause excessive wear (Bishop & Totten, 2003). Oxidative breakdown pushes viscosity down, so in a system with hot spots the rise from lost water and the fall from breakdown can overlap.

Measure temperature along the fluid's path, not only in the tank. An infrared thermometer on the fluid before and after the cooler, the cooling water flow, the surface of pipes and hoses near heat sources, and the relief valve body shows where heat builds. Compare the sample's pH, colour and smell side by side with new fluid, and if acid is suspected, have a laboratory analyse organic acids such as formic acid. Compare the measured temperatures with the supplier's operating range; one pump maker's guide sets water-glycol operating temperature between minus 20 °C and 60 °C (Danfoss, 2016).

Where a hot spot turns up, cutting off that heat comes first. Restore cooling water flow and heat transfer surfaces in the cooler, shield or reroute piping beside heat sources, and check the setting and circuit of any relief valve that stays open. If acids have already built up, replenishing additives alone will not reverse it, so review the analysis with the supplier and decide on a partial or full change. If heat remains along the same path after a change, the new fluid will go the same way.

Hypothesis 3: spent amine

When water is topped up faithfully and viscosity is in range, yet rust and pump wear continue, look at the additives. This is especially so for long-serving fluid, for systems topped up with tap or well water, for tanks opened often and for systems that run hot. A typical case: the tank shows viscosity and water both within limits, but when opened, rust has spread on the underside of the lid and on the walls above the fluid, and the return filter holds more fine iron particles than before.

The amine in a water-glycol handles both wear and rust. Part of it pairs with fatty acids to form the amine carboxylate that protects against wear, and the remaining free amine guards iron against rust both in the liquid and in the space above it. Wear rises as amine falls, and once the antiwear additive drops below a critical level, wear climbs sharply. With amine far below the optimum, vapour-phase corrosion of iron above the fluid worsens, and far above it, liquid-phase corrosion of non-ferrous metals does. Ions such as calcium and magnesium in make-up water react with the antiwear additive and remove it, so the harder the make-up water, the faster the additive is used up (Bishop & Totten, 2003). That fluid composition governs pump wear is also a point made by work on water-glycol performance monitoring (Wachter et al., 1995).

Additive level is read from pH and reserve alkalinity. Reserve alkalinity is reported as the amount of dilute hydrochloric acid needed to titrate 100 mL of sample to pH 5.5, and the two breaks in the titration curve correspond to the amine carboxylate and the free amine. One maintenance guide recommends keeping pH above 8.0 (Bishop & Totten, 2003). The trend against new fluid and past samples matters more than a single value, so measure by the same method at regular intervals and watch the slope of the decline. Measure the hardness or conductivity of the make-up water as well, and note whether rust sits only above the fluid or also on wetted parts.

Depleted additives are restored with the supplier's recommended additive or concentrate while watching the analysis, never in one large dose, since excess amine harms non-ferrous metals. Switch make-up to deionised or low-hardness water so the same depletion does not repeat. Keep the tank closed, and where rust above the fluid is heavy, schedule cleaning so it does not flake into the fluid.

Hypothesis 4: mineral oil

Consider this hypothesis after a mineral oil system has been converted to water-glycol, after maintenance in which oil from a similar-looking drum went in, after oil has leaked across from a nearby gearbox or lubrication system, or after a filter cart or hoses have been shared with another system. Think of a tank opened a few weeks after a major overhaul: it shows a thin oil layer floating on the surface, and foam at the return takes longer to collapse than it used to.

Mineral oil does not dissolve in water-glycol, so it floats up and forms a separate layer. The layer can be skimmed off, but if left too long, additives move from the fluid into the oil and leave with it when it is removed (Bishop & Totten, 2003). The pump then runs on fluid with less antiwear additive, and the oil left in the fluid is a more combustible component that erodes fire resistance (ISO, 2024). Contaminants can also impair the fluid's ability to release air, tipping it towards foam and bubbles that linger (Totten et al., 1997).

Checking starts with the eye. Look at the tank surface, take a sample in a clear bottle and let it stand to see whether a separate oil layer forms. In a layered tank the sample depends on the depth it is drawn from, so take one from the top and one from the bottom and compare them. Then trace the records backwards: how the system was flushed at conversion, what has been topped up recently, whether a nearby system has been losing oil, and where the filter cart and hoses were also used. If an oil layer is found, additives may have gone with it, so measure reserve alkalinity again.

When an oil layer appears, skim it off without delay. Finding and closing the route it came in by comes next, and if residual oil from the conversion is the cause, flush again following the supplier's conversion procedure. The correct procedure for converting a mineral oil system to water-glycol, and ways to trace the common causes of failure during the switch, have been set out separately (Totten & Bishop, 2000). Mark the fluid type clearly on drums and top-up containers, and keep the filter cart and hoses dedicated to water-glycol. After skimming, decide from the additive analysis whether to replenish. If a large amount has mixed in or fire resistance is in doubt, do not judge on the floor; get the supplier's analysis.

Hypothesis 5: air and cavitation

Air and cavitation are worth suspecting in a system where only the fluid was changed to water-glycol while the pump and suction piping designed for mineral oil stayed, where the pump sits above the tank or the suction line is long and narrow, where the suction strainer is clogging, or where the pump goes straight to high speed on a cold morning. At first start in the morning the pump sounds as if gravel were rolling through it, settling once the fluid warms, and a pump taken apart shows pitted, cratered marks on the valve plate rather than scratches.

A water-containing fire-resistant fluid has a vapour pressure far higher than mineral oil, varying with temperature, and a higher density that raises pressure losses in the suction line. So the pump suction must be designed to minimise the risk of cavitation, filters other than coarse strainers should be kept out of suction lines, and the pump inlet pressure should ideally exceed 100 kPa, or 1 bar, absolute (ISO, 2024). One pump maker's guide likewise calls for a raised reservoir and a larger suction line with water-glycol (Danfoss, 2016). When suction pressure falls near the vapour pressure, bubbles form in the liquid and collapse on the high-pressure side, striking the metal surface; this cavitation erosion lowers pump efficiency and leads to wear and failure, to a degree set jointly by the fluid's properties and the pump's operation (Svedberg et al., 1999).

Fit a vacuum or pressure gauge at the pump inlet, measure suction pressure in operation, and compare it with the limit the pump maker sets for this fluid. See whether it drops further on cold mornings or after viscosity has risen. Confirm that pump speed is within the rating reduced for water-glycol, that no fine filter sits in the suction line, that the strainer is not clogged and that no air leaks in at suction joints. In the tank, look for foam at the return and bubbles below the surface; on parts taken out, see whether pitting is concentrated where suction passes over to delivery.

The answer is to win back suction pressure. Clean the strainer, remove any fine filter from the suction line, tighten joints and keep the return line outlet below the fluid surface. If that is not enough, raise the tank above the pump so fluid flows into it, or change to a shorter, larger suction line, and review with the pump maker a speed reduction to the water-glycol rating. On cold days, warm up at low speed before loading. If viscosity was high, correct the water balance first, or the suction work cannot show its full effect.

Finding the cause

Five hypotheses do not mean opening the pump first. Rule them out starting with what is easy to measure. Level, tank temperature and the make-up log can be seen at once, and viscosity, water and pH come from a single sample. Reserve alkalinity, organic acids and oil layer analysis come next, and pump inlet pressure readings and parts inspection, which need the system stopped, come last.

The pattern of the numbers points the way. Rising viscosity with low water points to water balance first. If viscosity has fallen at the same water content, suspect oxidation or thermal breakdown and look for hot spots (Bishop & Totten, 2003). Viscosity and water in range, but pH and reserve alkalinity falling and rust spreading above the fluid, point to the amine inhibitor. An oil layer on the surface points to mineral oil, and noise concentrated on cold mornings and at the suction, with pitted parts, points to air and cavitation.

If that still does not settle it, change one thing at a time. Bring water back into range and see whether viscosity and noise recover together; compare warm and cold running with a gauge on the pump inlet; restore cooler flow and see whether the changes in colour and pH stop. Only one change at a time shows which one worked. Contamination level also affects wear across components, so measure particle cleanliness and wear debris at the same intervals and compare them as well (Wachter et al., 1995).

The final check comes from the pump parts. Pitted craters can point to cavitation erosion (Svedberg et al., 1999), scratch lines and fine iron particles to poor lubrication or particle contamination, and corrosion marks to acid or a lack of inhibitor. Each time a pump is changed, keep the removed parts, photographed, alongside the fluid analysis, so that the next failure can be compared at once.

The hypotheses often overlap. A hot spot drives off water and raises viscosity while making acids that eat into reserve alkalinity; thickened fluid makes life harder at the suction; mineral oil that gets in takes additives out with it. In such cases put water and temperature right first, then additives and contamination, and last the hardware such as suction piping and the pump, because while water and temperature are unsettled the effect of any other fix cannot be compared fairly.

Limits and cautions

Control ranges and make-up methods for water, viscosity, pH and reserve alkalinity differ by formulation, so numeric decisions follow the fluid's TDS and the supplier's analysis. Pump speed, pressure and suction limits follow what the pump maker sets for this fluid. Fire resistance cannot be judged on the floor, and where equipment depends on an approved fire-resistant fluid, confirm with the supplier that make-up and additive dosing stay within the terms of that approval. When changing to a different fluid type, follow the conversion procedure the standard sets out (ISO, 2024).

Safety matters too. Wear the protective equipment that the safety data sheet, the SDS, specifies for the fluid and any make-up additive, clean up spills at once so no one slips, and dispose of waste fluid according to the SDS and local rules. Stop the system and release pressure before taking samples or fitting gauges, and take care against burns when measuring near hot piping.

Sources

  1. ASTM International. (2024). ASTM D445-24, Standard test method for kinematic viscosity of transparent and opaque liquids (and calculation of dynamic viscosity). https://store.astm.org/d0445-24.html
  2. Bishop, R. J., & Totten, G. E. (2003). Water-glycol hydraulic fluid maintenance and analysis. Machinery Lubrication, January 2003. https://www.machinerylubrication.com/Read/442/water-glycol-hydraulic-fluid
  3. Danfoss. (2016). Hydraulic fluids and lubricants: Technical information (520L0463). https://assets.danfoss.com/documents/latest/54030/BC152886484524en-000902.pdf
  4. Grunberg, L., Jamieson, D. T., Scott, D., & Lloyd, R. A. (1960). Hydrogen diffusion in water-accelerated rolling surface fatigue. Nature, 188(4757), 1182–1183. https://doi.org/10.1038/1881182b0
  5. International Organization for Standardization [ISO]. (2024). ISO 7745:2024, Hydraulic fluid power — Fire-resistant fluids — Requirements and guidelines for use. https://www.iso.org/standard/84811.html
  6. Loftus, J. J. (1981). An assessment of three different fire resistance tests for hydraulic fluids (NBSIR 81-2395). National Bureau of Standards. https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nbsir81-2395.pdf
  7. Svedberg, G., Totten, G. E., Sun, Y., & Bishop, R. J. (1999). Hydraulic system cavitation: Part II – A review of hardware design-related effects (SAE Technical Paper 1999-01-2857). https://doi.org/10.4271/1999-01-2857
  8. Totten, G. E., & Bishop, R. J. (1995). Historical overview of the development of water-glycol hydraulic fluids (SAE Technical Paper 952076). https://doi.org/10.4271/952076
  9. Totten, G. E., & Bishop, R. J. (2000). Water-glycol hydraulic fluids: Conversion and troubleshooting of mineral oil hydraulic systems (SAE Technical Paper 2000-01-2589). https://doi.org/10.4271/2000-01-2589
  10. Totten, G. E., Bishop, R. J., McDaniels, R. L., Braniff, D. P., & Irvine, D. J. (1994). Effect of low molecular weight carboxylic acids on hydraulic pump wear (SAE Technical Paper 941751). https://doi.org/10.4271/941751
  11. Totten, G. E., Sun, Y., & Bishop, R. J. (1997). Hydraulic fluids: Foaming, air entrainment, and air release – A review (SAE Technical Paper 972789). https://doi.org/10.4271/972789
  12. Wachter, D., Bishop, R., McDaniels, R., & Totten, G. (1995). Water-glycol hydraulic fluid performance monitoring: Fluid performance and analysis strategy (SAE Technical Paper 952155). https://doi.org/10.4271/952155

Product and site consultation

Leave your company, site and the product groups in use. Our engineer will get in touch to go through your site conditions and concerns. Materials, equipment, operating conditions and downstream steps show what should change and what can stay. If nothing needs to change, we will say so.

Contact us
After you contact us
  1. 01
    Site setup

    We confirm process conditions and needs first.

  2. 02
    Spec design

    We set the product spec and selection criteria.

  3. 03
    Comparison

    We compare matching candidates and propose.

  4. 04
    Tailored supply

    We supply on time and manage the stock.

  5. 05
    Site check

    We visit, check conditions of use and record.

  6. 06
    Use management

    We track use and change cycles to catch issues.

  7. 07
    Regular analysis

    We analyze the records and send a yearly report.